Partial Discharge Measurement of 4 Types of Electrodes Configuration in Air Insulation using High Frequency Current Transformer Sensor

被引:0
|
作者
Ra, Nhet [1 ,2 ]
Khayam, Umar [2 ]
机构
[1] Inst Technol Cambodia, Elect & Elect Engn Dept, Phnom Penh, Cambodia
[2] Inst Teknol Bandung, Sch Elect Engn & Informat, Bandung, Indonesia
关键词
partial discharge; needle-plane electrode; needlesphere electrode; sphere-plane electrode; needle-needle electrode;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper deals with the occurrence of Partial Discharges on electrical equipment due to the high electric field exceeding the electric strength of Air. We can model PD occur in electrical equipment by using 4 types of electrode arrangement. There are Needle-Plane, Needle-Sphere, Needle-Needle, and Needle-Sphere. In this experiment, 4 types of electrodes with 10 mm gap between the two electrodes were used to produce a high electric field. PD measurement was conducted using phase-resolved measurement system which able to measure the PD magnitude, phase of PD occurrence as well as PD number. The task was done using a digital oscilloscope combined with a personal computer. The analysis of the PD data was conducted by utilizing phase-resolve PD pattern patterns. The experimental results showed that PD took place at around the peak of the applied voltage. Phase-resolved analysis indicated that partial discharge magnitude as well as partial discharge occurrence were strongly dependent on the instantaneous applied voltage. The simulation was able to generate phase-resolve PD pattern patterns similar to those obtained from the experiment.
引用
收藏
页码:100 / 105
页数:6
相关论文
共 47 条
  • [31] Noise Measurement in High Voltage Laboratory by using High Frequency Current Transformer and Loop Antenna
    Uwiringiyimana, Jean Pierre
    Khayam, Umar
    2017 INTERNATIONAL CONFERENCE ON HIGH VOLTAGE ENGINEERING AND POWER SYSTEMS (ICHVEPS), 2017, : 35 - 39
  • [32] High-Frequency Partial Discharge Characteristics of Solid-State Transformer Interturn Multilayer Insulation Under Repetitive Electrical Stress
    Li, Zhihui
    Han, Yaoxuan
    Xie, Zengqi
    Ren, Hanwen
    Li, Qingmin
    Wang, Zhongdong
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2024, 71 (10) : 13331 - 13340
  • [33] Principles of Charge Estimation Methods Using High-Frequency Current Transformer Sensors in Partial Discharge Measurements (vol 20, 2520, 2020)
    Rodrigo-Mor, Armando
    Munoz, Fabio A.
    Castro-Heredia, Luis Carlos
    SENSORS, 2021, 21 (18)
  • [34] Application of Improved Adaptive Parameterless Empirical Wavelet Transform in Transformer High Frequency Partial Discharge Current Noise Suppression
    Tang Z.
    Li Y.
    Dianwang Jishu/Power System Technology, 2023, 47 (08): : 3474 - 3482
  • [35] Study of A Partial Discharge Location Technique for Power Cables Using High Frequency Current Transducer
    Paophan, Busayapol
    Kunakorn, Anantawat
    Yutthagowith, Peerawut
    Pumyoy, Suparat
    2018 AUSTRALASIAN UNIVERSITIES POWER ENGINEERING CONFERENCE (AUPEC), 2018,
  • [36] Multiband Frequency of 4th Order Hilbert Fractal UHF Sensor Modelling for Partial Discharge Detection in Power Transformer
    Roslizan, N. D.
    Rohani, M. N. K. H.
    Rosmi, A. S.
    Ismail, B.
    Jamlos, M. A.
    Aihsan, M. Z.
    IEACON 2021: 2021 IEEE INDUSTRIAL ELECTRONICS AND APPLICATIONS CONFERENCE (IEACON), 2021, : 286 - 291
  • [37] Characterization of DC corona discharge current pulses using high-frequency measurement techniques
    Uckol, Halil Ibrahim
    Ilhan, Suat
    MEASUREMENT, 2023, 218
  • [38] Determining the exact location of partial discharge in coil insulation of high-voltage machine using high-frequency model of the machine
    Khezri, Hamid Reza
    Akbari, HamidReza
    Saied, SeyedAmin
    IET SCIENCE MEASUREMENT & TECHNOLOGY, 2020, 14 (09) : 753 - 761
  • [39] Partial Discharge Characteristics of Mineral Oil Using Needle - Plane and Needle -Sphere Electrode Configuration Base on Pulse Current Measurement
    Pattanadech, N.
    Pratomosiwi, F.
    Wieser, B.
    Baur, M.
    Muhr, M.
    2012 ANNUAL REPORT CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA (CEIDP), 2012, : 64 - 67
  • [40] A high-frequency phase feature for the measurement of magnetic permeability using eddy current sensor
    Lu, Mingyang
    Meng, Xiaobai
    Huang, Ruochen
    Chen, Liming
    Peyton, Anthony
    Yin, Wuliang
    NDT & E INTERNATIONAL, 2021, 123