Evaluation of inherent distortions in the IIST facility using the RELAP5/MOD3 code

被引:2
|
作者
Ferng, YM
机构
[1] Institute of Nuclear Energy Research, Lung-Tan 325
关键词
D O I
10.13182/NSE96-A24182
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
The Institute of Nuclear Energy Research (INER) integral system test (IIST) facility is a reduced-height, reduced-pressure test facility constructed at INER that is used to simulate the thermal hydraulics of the Maanshan nuclear power plant (NPP). A small-scaled facility is not capable of simulating all the physical phenomena of an NPP because the behavior of an NPP during accidents is very complicated. Proper scaling then plays an important role in the design of a test facility to ensure the usefulness and applicability of experimental data obtained from a small-scaled facility. However, distortions caused by necessary compromises in the design and construction of a small-scaled test facility exist. The analysis here evaluates whether the inherent distortions in the IIST facility will distort the thermal-hydraulic behaviors of a natural-circulation experiment and influence the usefulness and applicability of the experimental data. Based on the current calculations, the IIST experimental results are found to be partially distorted. Appropriate consideration of and correction for these distortion effects are needed before the results of the IIST natural-circulation experiments can be used to reliably investigate the Maanshan NPP behavior expected by way of an appropriate scale-up procedure.
引用
收藏
页码:190 / 205
页数:16
相关论文
共 50 条
  • [41] RELAP5/MOD3 CODE VERIFICATION THROUGH PWR PRESSURE VESSEL SMALL BREAK LOCA TESTS IN OECD/NEA ROSA PROJECT
    Nakamura, Hideo
    Watanabe, Tadashi
    Takeda, Takeshi
    Asaka, Hideaki
    Kondo, Masaya
    Maruyama, Yu
    Ohtsu, Iwao
    Suzuki, Mitsuhiro
    ICONE16: PROCEEDING OF THE 16TH INTERNATIONAL CONFERENCE ON NUCLEAR ENGINEERING - 2008, VOL 3, 2008, : 659 - 668
  • [42] Design, experiments and Relap5 code calculations for the perseo facility
    Ferri, R
    Achilli, A
    Cattadori, G
    Bianchi, F
    Meloni, P
    NUCLEAR ENGINEERING AND DESIGN, 2005, 235 (10-12) : 1201 - 1214
  • [43] Loss-of-heat-sink transient simulation with RELAP5/Mod3.3 code for the ATHENA facility
    Del Moro, T.
    Giannetti, F.
    Puviani, P. Cioli
    Di Piazza, I.
    Diamanti, D.
    Tarantino, M.
    ANNALS OF NUCLEAR ENERGY, 2025, 211
  • [44] 基于RELAP5/MOD3变功率分布的提棒事故分析方法研究
    张勇
    李松蔚
    王玮
    核动力工程, 2018, 39 (02) : 101 - 103
  • [45] Analytical activities for the QUENCH facility using the mechanistic code system SCDAP/RELAP5
    Homann, C
    Hering, W
    ANNUAL MEETING ON NUCLEAR TECHNOLOGY '99, PROCEEDINGS, 1998, : 263 - 266
  • [46] THE RELAP5-FORCE MOD2 CODE, A HYDRODYNAMIC FORCING FUNCTION CALCULATION VERSION OF RELAP5
    CAJIGAS, JM
    NUCLEAR TECHNOLOGY, 1990, 90 (03) : 316 - 325
  • [47] RELAP5/MOD3 analysis of a ROSA-IV/LSTF loss-of-RHR experiment with a 5% cold leg break
    Korea Atomic Energy Research Inst, Taejeon, Korea, Republic of
    Ann Nucl Energy, 4 (275-285):
  • [48] RELAP5/MOD3 analysis of a ROSA-IV/LSTF loss-of-RHR experiment with a 5% cold leg break
    Choi, CJ
    Nakamura, H
    ANNALS OF NUCLEAR ENERGY, 1997, 24 (04) : 275 - 285
  • [49] MODELING TBM COMPONENTS BY USING RELAP5 CODE
    Zhang, Yaoli
    Peng, Tianji
    PROCEEDINGS OF THE 21ST INTERNATIONAL CONFERENCE ON NUCLEAR ENGINEERING - 2013, VOL 5, 2014,