Validation of an automated home blood pressure measurement device in oldest-old populations

被引:8
|
作者
Godai, Kayo [1 ]
Kabayama, Mai [1 ]
Saito, Kanako [2 ]
Asayama, Kei [3 ,4 ]
Yamamoto, Koichi [5 ]
Sugimoto, Ken [5 ]
Ohkubo, Takayoshi [3 ,4 ]
Rakugi, Hiromi [5 ]
Kamide, Kei [1 ,5 ]
机构
[1] Osaka Univ, Grad Sch Med, Div Hlth Sci, Osaka, Japan
[2] Omron Healthcare Co Ltd, Kyoto, Japan
[3] Teikyo Univ, Dept Hyg & Publ Hlth, Sch Med, Tokyo, Japan
[4] Tohoku Inst Management Blood Pressure, Sendai, Miyagi, Japan
[5] Osaka Univ, Dept Geriatr & Gen Med, Grad Sch Med, Osaka, Japan
关键词
Blood pressure; Validation; Oldest-old; Oscillometric device; ISO; 81060-2; ANTHROPOMETRIC REFERENCE DATA; INTERNATIONAL-PROTOCOL; EUROPEAN-SOCIETY; ANSI/AAMI/ISO; 81060-2/2013; HYPERTENSION; AGE; ASSOCIATION; PREVALENCE; STIFFNESS; AWARENESS;
D O I
10.1038/s41440-019-0330-7
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
Despite the wide use of automated devices for the self-measurement of home blood pressure (BP), no evidence is available regarding the accuracy of such devices in oldest-old populations. The aim of this study was to validate the accuracy of the automated oscillometric upper arm-cuff BP-monitoring device according to an international protocol in oldest-old individuals. In 35 participants aged over 85 years old, BP was measured on the same arm sequentially using a mercury sphygmomanometer (by two observers) and an Omron HEM-7080IC. The difference between the test device and observer measurements and associated factors were evaluated according to the International Organization for Standardization (ISO) 81060-2:2013 protocol. A total of 105 pairs (three pairs per participant) of the test device and observer BP measurements were obtained. The mean (+/- standard deviation: SD) differences in systolic BP (SBP) and diastolic BP (DBP) between the methods were -0.7 +/- 7.1 and -1.1 +/- 4.5 mmHg, respectively, and those for each participant were -0.7 +/- 5.8 mmHg for SBP and -1.1 +/- 4.1 mmHg for DBP; the device therefore fulfilled the requirements of the ISO protocol. In the multivariate analysis with the linear mixed model, the difference was associated with the cuff size for SBP and pulse pressure for DBP. The Omron HEM-7080IC passed the ISO requirements for oldest-old individuals aged 85 years or older. This device can be recommended for clinical and self/home use in oldest-old populations.
引用
收藏
页码:30 / 35
页数:6
相关论文
共 50 条
  • [21] Repeated office blood pressure measurement by automated device to evaluate blood pressure control
    Crippa, G
    Sverzellati, E
    Venturi, C
    Antoniotti, P
    AMERICAN JOURNAL OF HYPERTENSION, 2003, 16 (05) : 46A - 46A
  • [22] Inverse Relationship Between Depressive Symptoms and Arterial Blood Pressure in Community-Dwelling Oldest-Old Brazilians
    Rosset, Idiane
    Rodrigues, Rosalina Partezani
    Rizzi, Liara
    Canuto-Neto, Jose
    Roriz-Cruz, Matheus
    JOURNAL OF THE AMERICAN GERIATRICS SOCIETY, 2013, 61 (03) : 465 - 467
  • [23] EVALUATION OF A DIGITAL DEVICE FOR HOME BLOOD-PRESSURE MEASUREMENT
    BURRIS, JF
    PHILLIPS, M
    CLINICAL RESEARCH, 1982, 30 (02): : A638 - A638
  • [24] DEVICE FOR HOME MEASUREMENT OF INDIRECT ARTERIAL BLOOD-PRESSURE
    TIEP, B
    RODBARD, S
    CIRCULATION, 1974, 50 (04) : 209 - 209
  • [25] Relationships Between Hair Chemical Elements and Nutritional Status in Oldest-Old and Centenarian Populations
    Zhu, Qiao
    Zhao, Qingkai
    Ping, Ping
    Zhang, Qian
    Gong, Li
    Feng, Long
    Zhao, Yali
    Fu, Shihui
    JOURNAL OF MULTIDISCIPLINARY HEALTHCARE, 2023, 16 : 1171 - 1178
  • [26] Validation of the Finometer device for measurement of blood pressure in black women
    A E Schutte
    H W Huisman
    J M van Rooyen
    N T Malan
    R Schutte
    Journal of Human Hypertension, 2004, 18 : 79 - 84
  • [27] Validation of the Finometer device for measurement of blood pressure in black women
    Schutte, AE
    Huisman, HW
    van Rooyen, JM
    Malan, NT
    Schutte, R
    JOURNAL OF HUMAN HYPERTENSION, 2004, 18 (02) : 79 - 84
  • [28] The Comparison of Office Blood Pressure with Morning Home Blood Pressure: Self-Automated Measurement
    Suntornlekha, Nutnicha
    Kuanprasert, Srun
    Chai-Adisaksopha, Chatree
    Jesadaporn, Panas
    Mekara, Warangkana
    Leemasawat, Krit
    HYPERTENSION, 2024, 81
  • [29] Trends in blood pressure and hypertension among older adults and oldest-old individuals in China between 2008-2018
    Tan, Siyue
    Liu, Dong
    Zhang, Yuyi
    Li, Shengnan
    Zhang, Ke
    Zuo, Hui
    HYPERTENSION RESEARCH, 2023, 46 (05) : 1145 - 1156
  • [30] Automated measurement of office, home and ambulatory blood pressure in atrial fibrillation
    Kollias, Anastasios
    Stergiou, George S.
    CLINICAL AND EXPERIMENTAL PHARMACOLOGY AND PHYSIOLOGY, 2014, 41 (01) : 9 - 15