On-load measurement method for the reliability of distribution transformers

被引:2
|
作者
Adesina, Lambe Mutalub [1 ]
Abdulkareem, Ademola [2 ]
Ogunbiyi, Olalekan [1 ]
Ibrahim, Oladimeji [3 ]
机构
[1] Kwara State Univ, Fac Engn & Technol, Dept Elect & Comp Engn, Malete, Nigeria
[2] Covenant Univ, Dept Elect & Informat Engn, Sango Ota, Ogun State, Nigeria
[3] Univ Ilorin, Dept Elect & Elect Engn, Ilorin, Nigeria
关键词
Cellulose deterioration; Energy analyzer; Experiment; Fluke; Insulation; Network reliability; Outages; Power quality;
D O I
10.1016/j.mex.2020.101089
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Transformer is the most important equipment used in power system. It's ensure network stability and reliability. Transformer fails over time due to several factors such as overload, poor insulation, cellulose deterioration, poor dielectric strength of the oil etc. However, transformer owners are finding it difficult to monitor the performance of distribution transformers (DT) in their place of application which results to system failure. Analyses of this distribution transformer performance required that distribution transformer be put on-load and the secondary terminals link to Power Quality and Energy Analyzer equipment (Fluke 435 Series II). This paper presents a methodology of carrying out experimental set up of on-load reliability measurements of the two distribution transformers, 500 kVA and 300 kVA, 11/0.415 kV as case study. Recommendations for the operations and maintenance engineers in charge to comply are discussed. This approach using the prescribed power quality equipment gives a reliable experimental method of evaluating the performance of distribution transformers. Maintaining the selected distribution transformer on - load prior to and during the experiment. The setting of experimental circuit to determine the operational parameters involving DT connection to Power Quality and Energy Analyzer (PQEA) equipment. It utilize personal computer to download the measured parameters for graphical and statistics analysis. (C) 2020 The Authors. Published by Elsevier B.V.
引用
收藏
页数:22
相关论文
共 50 条
  • [41] A Hybrid Diverter Design for Distribution Level On-load Tap Changers
    Rogers, Daniel J.
    Green, Tim C.
    2010 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION, 2010, : 1493 - 1500
  • [42] Discussion on Arcless On-Load Automatic Capacity Regulating Distribution Transformer
    Piao, Zailin
    Wang, Dongdong
    Zheng, Yu
    POWER AND ENERGY ENGINEERING CONFERENCE 2010, 2010, : 323 - 326
  • [43] ON-LOAD TAP CHANGERS
    JUNG, V
    ELIN ZEITSCHRIFT, 1977, 29 (03): : 109 - 114
  • [44] CONTRIBUTIONS TO THE DEVELOPMENT OF DEVICES TO INCREASE SAFETY IN OPERATION OF THE ON-LOAD -TAP-CHANGERS OF THE POWER TRANSFORMERS
    Cujba, Tiberiu
    Cernomazu, Dorel
    UNIVERSITY POLITEHNICA OF BUCHAREST SCIENTIFIC BULLETIN SERIES C-ELECTRICAL ENGINEERING AND COMPUTER SCIENCE, 2011, 73 (02): : 251 - 262
  • [45] DISCUSSION ON PARALLEL OPERATION OF TRANSFORMERS WITH ON-LOAD TAP CHANGERS AND NEGATIVE-REACTANCE-COMPOUNDING CONTROL
    WHITCHER, AE
    ECCLES, J
    PETRIE, JB
    HASELFOO.AJ
    GLOVER, AJ
    PROCTOR, AH
    FOWLER, GH
    HUDDART, KW
    RIPPON, EC
    CARPENTE.RH
    TAYLOR, W
    WHETTON, H
    REID, IA
    BONSON, HG
    COWAN, JM
    EDMONDSO.KL
    PRESTON, LL
    PROCEEDINGS OF THE INSTITUTION OF ELECTRICAL ENGINEERS-LONDON, 1965, 112 (12): : 2284 - &
  • [46] THE EFFECTS OF COLD LOAD PICKUP ON DISTRIBUTION TRANSFORMERS
    WILDE, RL
    IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1981, 100 (05): : 2433 - 2437
  • [47] IMPULSE TESTING OF DISTRIBUTION TRANSFORMERS UNDER LOAD
    KAUFMANN, GH
    IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1977, 96 (05): : 1583 - 1595
  • [48] Application of the Acoustic Emission Method for Diagnosis of On-Load Tap Changer
    Majchrzak, Henryk
    Cichon, Andrzej
    Borucki, Sebastian
    ARCHIVES OF ACOUSTICS, 2017, 42 (01) : 29 - 35
  • [49] Probabilistic evaluation of distribution power transformers reliability indices considering load transfers and mobile unit substations
    Costa, Joao Guilherme de C.
    Leite da Silva, Armando M.
    Hamoud, Gomaa A.
    Pureza, Izabela M.
    Silva Neto, Noe
    ELECTRIC POWER SYSTEMS RESEARCH, 2020, 187
  • [50] Dynamic behaviour of a suspended bubble and its influence on the distribution of electric fields in insulating oil of an on-load tap-changer within power transformers
    Liu, Chenlei
    Zhao, Tong
    Sun, Ying
    Wang, Xiaolong
    Cao, Shi
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2023, 145