Neural Mechanisms Underlying High-Frequency Vestibulocollic Reflexes In Humans And Monkeys

被引:17
|
作者
Forbes, Patrick A. [1 ,2 ]
Kwan, Annie [3 ]
Rasman, Brandon G. [1 ,4 ,5 ,6 ]
Mitchell, Diana E. [3 ]
Cullen, Kathleen E. [3 ,7 ]
Blouin, Jean-Sebastien [5 ,6 ]
机构
[1] Erasmus MC, Dept Neurosci, NL-3015 GD Rotterdam, Netherlands
[2] Delft Univ Technol, Fac Mech Maritime & Mat Engn, Dept Biomech Engn, NL-2628 CD Delft, Netherlands
[3] McGill Univ, Dept Biomed Engn, Montreal, PQ H3G 1Y6, Canada
[4] Univ Otago, Sch Phys Educ Sport & Exercise Sci, Dunedin 9016, New Zealand
[5] Univ British Columbia, Djavad Mowafaghian Ctr Brain Hlth, Sch Kinesiol, Vancouver, BC V6T 1Z1, Canada
[6] Univ British Columbia, Inst Comp Informat & Cognit Syst, Vancouver, BC V6T 1Z1, Canada
[7] Johns Hopkins Univ, Dept Biomed Engn, Baltimore, MD 21205 USA
来源
JOURNAL OF NEUROSCIENCE | 2020年 / 40卷 / 09期
基金
加拿大健康研究院; 加拿大自然科学与工程研究理事会;
关键词
high frequency; human; neck motor units; non-human primates; vestibular afferents; vestibulocollic reflex; HEAD ANGULAR-ACCELERATION; INDUCED NECK REFLEX; VESTIBULAR REFLEXES; INFORMATION-TRANSMISSION; VESTIBULOOCULAR REFLEX; DETECTION THRESHOLDS; DYNAMIC PROPERTIES; RESPONSE ANALYSIS; COLLIC REFLEX; RHESUS-MONKEY;
D O I
10.1523/JNEUROSCI.1463-19.2020
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
The vestibulocollic reflex is a compensatory response that stabilizes the head in space. During everyday activities, this stabilizing response is evoked by head movements that typically span frequencies from 0 to 30 Hz. Transient head impacts, however, can elicit head movements with frequency content up to 300-400 Hz, raising the question whether vestibular pathways contribute to head stabilization at such high frequencies. Here, we first established that electrical vestibular stimulation modulates human neck motor unit (MU) activity at sinusoidal frequencies up to 300 Hz, but that sensitivity increases with frequency up to a low-pass cutoff of similar to 70-80 Hz. To examine the neural substrates underlying the low-pass dynamics of vestibulocollic reflexes, we then recorded vestibular afferent responses to the same electrical stimuli in monkeys. Vestibular afferents also responded to electrical stimuli up to 300 Hz, but in contrast to MUs their sensitivity increased with frequency up to the afferent resting firing rate (similar to 100-150 Hz) and at higher frequencies afferents tended to phase-lock to the vestibular stimulus. This latter nonlinearity, however, was not transmitted to neck motoneurons, which instead showed minimal phase-locking that decreased at frequencies >75 Hz. Similar to human data, we validated that monkey muscle activity also exhibited low-pass filtered vestibulocollic reflex dynamics. Together, our results show that neck MUs are activated by high-frequency signals encoded by primary vestibular afferents, but undergo low-pass filtering at intermediate stages in the vestibulocollic reflex. These high-frequency contributions to vestibular-evoked neck muscle responses could stabilize the head during unexpected head transients.
引用
收藏
页码:1874 / 1887
页数:14
相关论文
共 50 条
  • [21] Current Activities on High-Frequency Exposure Guidelines for Humans
    Lin, James C.
    IEEE MICROWAVE MAGAZINE, 2015, 16 (04) : 28 - 32
  • [22] Sparse-regularized high-frequency enhanced neural network for solving high-frequency problems
    Huang, Qilin
    Fang, Mingjin
    Cheng, Dongsheng
    Lu, Chunyuan
    Zeng, Taishan
    JOURNAL OF COMPUTATIONAL PHYSICS, 2025, 523
  • [23] NEURAL SENSITIVITY TO PHASE OF HIGH-FREQUENCY TONES
    MCANALLY, KI
    CALFORD, MB
    HEARING RESEARCH, 1990, 44 (01) : 51 - 61
  • [24] HIGH-FREQUENCY SMALL-VOLUME VENTILATION IN ANESTHETIZED HUMANS
    CRAWFORD, M
    REHDER, K
    ANESTHESIOLOGY, 1985, 62 (03) : 298 - 304
  • [25] INTRAREGIONAL GAS MIXING IN HUMANS DURING HIGH-FREQUENCY OSCILLATIONS
    MOFFAT, SL
    BYFORD, L
    FORKERT, L
    RESPIRATION PHYSIOLOGY, 1986, 66 (01): : 95 - 107
  • [26] Extremely high-frequency micro-Doppler measurements of humans
    Hedden, Abigail S.
    Silvious, Jerry L.
    Dietlein, Charles R.
    Green, Jeremy A.
    Wikner, David A.
    RADAR SENSOR TECHNOLOGY XVIII, 2014, 9077
  • [27] High-frequency oscillations in circulating amylin concentrations in healthy humans
    Juhl, CB
    Porksen, N
    Sturis, J
    Hansen, ÅP
    Veldhuis, JD
    Pincus, S
    Fineman, M
    Schmitz, O
    AMERICAN JOURNAL OF PHYSIOLOGY-ENDOCRINOLOGY AND METABOLISM, 2000, 278 (03): : E484 - E490
  • [28] INTRAPULMONARY GAS MIXING DURING HIGH-FREQUENCY OSCILLATION IN HUMANS
    MOFFATT, SL
    BYFORD, LJ
    FORKERT, L
    FEDERATION PROCEEDINGS, 1984, 43 (03) : 322 - 322
  • [29] Different underlying mechanisms for high and low arousal in probabilistic learning in humans
    Ciria, Luis F.
    Suarez-Pinilla, Marta
    Williams, Alex G.
    Jagannathan, Sridhar R.
    Sanabria, Daniel
    Bekinschtein, Tristan A.
    CORTEX, 2021, 143 : 180 - 194
  • [30] Cholinergic mechanisms of high-frequency stimulation in entopeduncular nucleus
    Luo, Feng
    Kiss, Zelma H. T.
    JOURNAL OF NEUROPHYSIOLOGY, 2016, 115 (01) : 60 - 67