Implementation and Performance of Shutterless Uncooled Micro-Bolometer cameras

被引:4
|
作者
Das, J. [1 ]
de Gaspari, D. [1 ]
Cornet, P. [1 ]
Deroo, P. [1 ]
Vermeiren, J. [1 ]
Merken, P. [1 ,2 ]
机构
[1] Xenics Nv, BE-3001 Leuven, Belgium
[2] RMA, BE-1000 Brussels, Belgium
来源
关键词
Uncooled micro-bolometer; shutterless operation; response uniformity; residual non-uniformity (RNU);
D O I
10.1117/12.2177315
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A shutterless algorithm is implemented into the Xenics LWIR thermal cameras and modules. Based on a calibration set and a global temperature coefficient the optimal non-uniformity correction is calculated onboard of the camera. The limited resources in the camera require a compact algorithm, hence the efficiency of the coding is important. The performance of the shutterless algorithm is studied by a comparison of the residual non-uniformity (RNU) and signal-to-noise ratio (SNR) between the shutterless and shuttered correction algorithm. From this comparison we conclude that the shutterless correction is only slightly less performant compared to the standard shuttered algorithm, making this algorithm very interesting for thermal infrared applications where small weight and size, and continuous operation are important.
引用
收藏
页数:7
相关论文
共 50 条
  • [21] Long-Term Radiometric Stability of Uncooled and Shutterless Microbolometer-Based Infrared Cameras
    Gazzano, Olivier
    Chambon, Mathieu
    Ferrec, Yann
    Druart, Guillaume
    SENSORS, 2024, 24 (19)
  • [22] A ⟨100⟩ direction front-etched membrane structure for a micro-bolometer
    Ma, Tieying
    Liu, Yidong
    Li, Tie
    JOURNAL OF MICROMECHANICS AND MICROENGINEERING, 2009, 19 (03)
  • [23] Preparation and characteristics of vanadium oxide thin film for micro-bolometer application
    Ru, Guo-Ping
    Cao, Yong-Feng
    Li, Bing-Zong
    Weixi Jiagong Jishu/Microfabrication Technology, 2002, (04):
  • [24] Simple correction model for blurred images of uncooled bolometer type infrared cameras
    Nihei, Ryota
    Tanaka, Yutaka
    Iizuka, Hiroyuki
    Matsumiya, Takeshi
    INFRARED IMAGING SYSTEMS: DESIGN, ANALYSIS, MODELING, AND TESTING XXX, 2019, 11001
  • [25] High-Performance Infrared Micro-Bolometer Arrays Manufactured Using Very Large Scale Heterogeneous Integration
    Forsberg, Fredrik
    Fischer, Andreas C.
    Stemme, Goran
    Roxhed, Niclas
    Niklaus, Frank
    Ericsson, Per
    Samel, Bjorn
    OMN2011: 16TH INTERNATIONAL CONFERENCE ON OPTICAL MEMS AND NANOPHOTONICS, 2011, : 9 - +
  • [26] Potential application of micro-bolometer coupled antenna-pairs in beam synthesis
    Yang, Weidong
    Roggemann, Michael C.
    Middlebrook, Christopher
    Subotic, Nikola
    Buller, William
    Cooper, Kyle
    INFRARED SYSTEMS AND PHOTOELECTRONIC TECHNOLOGY III, 2008, 7055
  • [27] A monolithic resonant terahertz sensor element comprising a metamaterial absorber and micro-bolometer
    Grant, James
    Escorcia-Carranza, Ivonne
    Li, Chong
    McCrindle, Iain J. H.
    Gough, John
    Cumming, David R. S.
    LASER & PHOTONICS REVIEWS, 2013, 7 (06) : 1043 - 1048
  • [28] An approach for the performance analysis of an uncooled infrared bolometer imager
    Tsujino, Yoshiki
    INFRARED PHYSICS & TECHNOLOGY, 2010, 53 (01) : 50 - 60
  • [29] Study on characteristics and structures of amorphous silicon nitride thin films applied in micro-bolometer
    Zhou D.
    Xu X.
    Wang Z.
    Wang X.
    Jiang Y.
    Guangxue Xuebao/Acta Optica Sinica, 2010, 30 (10): : 2782 - 2787
  • [30] Vacuum quality evaluation for uncooled micro bolometer thermal imager sensors
    Elssner, Michael