Implementation and Performance of Shutterless Uncooled Micro-Bolometer cameras

被引:4
|
作者
Das, J. [1 ]
de Gaspari, D. [1 ]
Cornet, P. [1 ]
Deroo, P. [1 ]
Vermeiren, J. [1 ]
Merken, P. [1 ,2 ]
机构
[1] Xenics Nv, BE-3001 Leuven, Belgium
[2] RMA, BE-1000 Brussels, Belgium
来源
关键词
Uncooled micro-bolometer; shutterless operation; response uniformity; residual non-uniformity (RNU);
D O I
10.1117/12.2177315
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A shutterless algorithm is implemented into the Xenics LWIR thermal cameras and modules. Based on a calibration set and a global temperature coefficient the optimal non-uniformity correction is calculated onboard of the camera. The limited resources in the camera require a compact algorithm, hence the efficiency of the coding is important. The performance of the shutterless algorithm is studied by a comparison of the residual non-uniformity (RNU) and signal-to-noise ratio (SNR) between the shutterless and shuttered correction algorithm. From this comparison we conclude that the shutterless correction is only slightly less performant compared to the standard shuttered algorithm, making this algorithm very interesting for thermal infrared applications where small weight and size, and continuous operation are important.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Performance characterization of commercially available uncooled micro-bolometer thermal cameras for varying camera temperatures
    Minnaar, I. J.
    SENSORS, MEMS, AND ELECTRO-OPTICAL SYSTEMS, 2014, 9257
  • [2] Uncooled micro-bolometer based on amorphous germanium film
    Torres, A
    Kosarev, A
    Cruz, MLG
    Ambrosio, R
    JOURNAL OF NON-CRYSTALLINE SOLIDS, 2003, 329 (1-3) : 179 - 183
  • [3] On-Chip Excessive Heating Protection Scheme for Uncooled Micro-Bolometer Imagers
    Liu, Dahe
    Shi, Xueyou
    Chen, Guangyi
    Lu, Wengao
    Chen, Zhongjian
    2019 IEEE INTERNATIONAL CONFERENCE ON ELECTRON DEVICES AND SOLID-STATE CIRCUITS (EDSSC), 2019,
  • [4] Uncooled Infrared Micro-Bolometer FPA for Multiple Digital Correlated Double Sampling
    Kim, Minsik
    Park, Seunghyun
    Lee, Kwyro
    Yoo, Hyung-Joun
    IEEE PHOTONICS TECHNOLOGY LETTERS, 2018, 30 (06) : 517 - 520
  • [5] Subsurface damage detection of a steel bridge using deep learning and uncooled micro-bolometer
    Ali, Rahmat
    Cha, Young-Jin
    CONSTRUCTION AND BUILDING MATERIALS, 2019, 226 : 376 - 387
  • [6] Sub-10-pW/Hz0.5 Uncooled Micro-Bolometer With a Vacuum Micro-Package
    Yang, Hyun-Ho
    Rebeiz, Gabriel M.
    IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, 2016, 64 (07) : 2129 - 2136
  • [7] Uncooled terahertz video micro-bolometer camera: toolbox to optimize the sensitivity by tuning antennas and cavity
    Meilhan, J.
    Oden, J.
    Ouvrier-Buffet, J. L.
    Hamelin, A.
    Delplanque, B.
    Simoens, F.
    2016 41ST INTERNATIONAL CONFERENCE ON INFRARED, MILLIMETER, AND TERAHERTZ WAVES (IRMMW-THZ), 2016,
  • [8] Characterization of radio frequency sputtered SixGe1-xOy thin films for uncooled micro-bolometer
    Cheng, Q.
    Almasri, M.
    INFRARED TECHNOLOGY AND APPLICATIONS XXXIV, PTS 1 AND 2, 2008, 6940
  • [9] Basic approach to define signal-to-noise ratio for adjacent pixels for an uncooled micro-bolometer FPA detector
    Kurum, Ulas
    OPTICAL MODELING AND PERFORMANCE PREDICTIONS VI, 2013, 8840
  • [10] A Novel Test Method For Micro-bolometer Thermal Parameters
    Wei, He
    Tong, Zhou
    Qin, Shi
    Yan, Su
    2015 FIFTH INTERNATIONAL CONFERENCE ON INSTRUMENTATION AND MEASUREMENT, COMPUTER, COMMUNICATION AND CONTROL (IMCCC), 2015, : 1653 - 1657