Investigation of imaging performance of amorphous selenium flat-panel detectors for digital mammography

被引:13
|
作者
Zhao, W [1 ]
Ji, WG [1 ]
Rowlands, JA [1 ]
Debrie, A [1 ]
机构
[1] SUNY Stony Brook, Hlth Sci Ctr L 4, Dept Radiol, Stony Brook, NY 11794 USA
关键词
flat-panel detectors; digital mammography; MTF; NPS; DQE; selenium;
D O I
10.1117/12.430876
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Our work is to investigate and understand the factors affecting the imaging performance of amorphous selenium (a-Se) flat-panel detectors for digital mammography. Both theoretical and experimental methods were developed to investigate the spatial frequency dependent detective quantum efficiency [DQE(f)] of a-Se flat-panel detectors for digital mammography. Since the k-edge of a-Se is 12.66 keV and within the energy range of a mammographic spectrum, a cascaded linear system model was developed which takes into account the effect of k-fluorescence on the modulation transfer function (MTF), noise power spectrum (NPS) and DQE(f) of the detector. This model was used to understand the performance of a prototype detector with 85 mum. pixel size. The presampling MTF, NPS and DQE(f) of the prototype were measured, and compared to the theoretical calculation by the model. The calculation showed that k-fluorescence reduces the MTF by 15% at the Nyquist frequency (f(NY)) of the prototype detector, and the NPS at f(NY) was reduced to 82% of that at zero spatial frequency. The measurement of presampling MTF of the prototype detector revealed an additional source of blurring, which was attributed to the blocking layer at the interface between a-Se and the active matrix. This introduced high frequency drop in both presampling MTF and NPS, and reduced aliasing in the NPS. As a result, the DQE(f) of the prototype detector at f(NY) approaches 50% of that at zero spatial frequency.
引用
收藏
页码:536 / 546
页数:11
相关论文
共 50 条
  • [21] Digital radiography with flat-panel detectors: the missing link
    Michael Strotzer
    European Radiology, 2002, 12 : 1603 - 1604
  • [22] Imaging characteristics of an amorphous silicon flat-panel detector for digital chest radiography
    Floyd, CE
    Warp, RJ
    Dobbins, JT
    Chotas, HG
    Baydush, AH
    Vargas-Voracek, R
    Ravin, CE
    RADIOLOGY, 2001, 218 (03) : 683 - 688
  • [23] Temporal performance of amorphous selenium mammography detectors
    Zhao, B
    Zhao, W
    MEDICAL PHYSICS, 2005, 32 (01) : 128 - 136
  • [24] Amorphous selenium flat panel detectors for medical applications
    Zhao, W
    Hunt, DC
    Tanioka, K
    Rowlands, JA
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2005, 549 (1-3): : 205 - 209
  • [25] Performance evaluation of a flat-panel filmless full-field digital mammography system
    Rougeot, HM
    OpsahlOng, B
    Castleberry, DE
    Langberg, C
    Liu, J
    KimmeSmith, CM
    RADIOLOGY, 1996, 201 : 341 - 341
  • [26] Ghosting caused by bulk charge trapping in direct conversion flat-panel detectors using amorphous selenium
    Zhao, W
    DeCrescenzo, G
    Kasap, SO
    Rowlands, JA
    MEDICAL PHYSICS, 2005, 32 (02) : 488 - 500
  • [27] Solid-state, flat-panel, digital radiography detectors and their physical imaging characteristics
    Cowen, A. R.
    Kengyelics, S. M.
    Davies, A. G.
    CLINICAL RADIOLOGY, 2008, 63 (05) : 487 - 498
  • [28] Digital radiography with large-area flat-panel detectors
    E. Kotter
    M. Langer
    European Radiology, 2002, 12 : 2562 - 2570
  • [29] Imaging and Dosimetric Study on Direct Flat-Panel Detector-Based Digital Mammography System
    Sharma, Reena
    Sharma, S. D.
    Sarkar, P. S.
    Datta, D.
    JOURNAL OF MEDICAL PHYSICS, 2018, 43 (04) : 255 - 263
  • [30] Digital radiography with large-area flat-panel detectors
    Kotter, E
    Langer, M
    EUROPEAN RADIOLOGY, 2002, 12 (10) : 2562 - 2570