Aerothermal performance of square duct enhanced by twisted tape with inclined ribs and slots

被引:10
|
作者
Chang, S. W. [1 ]
Wu, P. S. [2 ]
Liu, J. H. [3 ]
机构
[1] Natl Cheng Kung Univ, Dept Syst & Naval Mechatron Engn, 1 Univ Rd, Tainan 70101, Taiwan
[2] Dayeh Univ, Dept Mech & Automat Engn, 168 Univ Rd, Changhua 51591, Dacun, Taiwan
[3] Natl Cheng Kung Univ, Dept Syst & Naval Mech Engn, 1 Univ Rd, Tainan 70101, Taiwan
关键词
Perforated slot; Inclined rib; Twisted tape; HEAT-TRANSFER AUGMENTATION; PRESSURE-DROP; CIRCULAR TUBE; FLOW; INSERTS; WATER; CUT;
D O I
10.1016/j.ijheatmasstransfer.2021.121547
中图分类号
O414.1 [热力学];
学科分类号
摘要
To reduce the pressure drop penalties with substantial heat transfer enhancements for the channel flows enhanced by a twisted tape insert, the conjugate inclined ribs and slots are newly devised to modify the twisted tape. The simulated flow and pressure fields generated by the inclined rib-slot element along a twisted tape are correlatively examined with the measured Nusselt numbers and Fanning friction factors. The tilted transverse ribs convert the flow re-circulation cell behind a vertical rib to the solenoidal vor-tex and trip the separated flows. The inclined slots enable the mass, momentum and energy exchanges between the two axial swirls along the two spiral pathways segregated by the twisted tape. These flow mechanisms induced by the twisted tape and the inclined ribs and slots act synergistically to improve the heat transfer performance with the lessened rib-induced form drags. The average Nusselt numbers are raised to 4.2-3.8 time of the Dittus-Boelter values at the expenses of the Fanning friction factor aug-mentations to 32.5-40.2 time of the Blasius levels at the range of Reynolds number between 10,0 0 0 and 50,0 0 0. Compared with the tubular flows enhanced by the ribbed twist tape, the heat transfer enhance-ments caused by the rib-slot element along a twisted tape in a square duct are similarly retained but the reductions in Fanning friction factor are substantial. The resultant aerothermal performance improve-ments achieved by the inclined rib-slot element lighten the prospective applications to heat exchangers involving swirl generators. To assist these applications, the empirical correlations that calculate the aver-age Nusselt number, Fanning friction factor and relative heat transfer power of a square duct enhanced by the twisted tape with the inclined slots and ribs are devised. (c) 2021 Elsevier Ltd. All rights reserved.
引用
收藏
页数:23
相关论文
共 42 条
  • [41] Analysis of efficiency and performance evaluation criterion of nanofluid flow within a tube enhanced with perforated triple twisted tape: A two-phase analysis
    Chen, Peijia
    Zhang, Yueqing
    Qu, Ying
    Xu, Tao
    He, Xin
    Gao, Baihui
    Golzar, Ali
    Nasajpour-Esfahani, Navid
    Hekmatifar, Maboud
    CASE STUDIES IN THERMAL ENGINEERING, 2023, 48
  • [42] A two-phase simulation for analyzing thermohydraulic performance of Cu-water nanofluid within a square channel enhanced with 90° V-shaped ribs
    Bahiraei, Mehdi
    Mazaheri, Nima
    Hosseini, Yaghoub
    Moayedi, Hossein
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2019, 145