Aerothermal performance of square duct enhanced by twisted tape with inclined ribs and slots

被引:10
|
作者
Chang, S. W. [1 ]
Wu, P. S. [2 ]
Liu, J. H. [3 ]
机构
[1] Natl Cheng Kung Univ, Dept Syst & Naval Mechatron Engn, 1 Univ Rd, Tainan 70101, Taiwan
[2] Dayeh Univ, Dept Mech & Automat Engn, 168 Univ Rd, Changhua 51591, Dacun, Taiwan
[3] Natl Cheng Kung Univ, Dept Syst & Naval Mech Engn, 1 Univ Rd, Tainan 70101, Taiwan
关键词
Perforated slot; Inclined rib; Twisted tape; HEAT-TRANSFER AUGMENTATION; PRESSURE-DROP; CIRCULAR TUBE; FLOW; INSERTS; WATER; CUT;
D O I
10.1016/j.ijheatmasstransfer.2021.121547
中图分类号
O414.1 [热力学];
学科分类号
摘要
To reduce the pressure drop penalties with substantial heat transfer enhancements for the channel flows enhanced by a twisted tape insert, the conjugate inclined ribs and slots are newly devised to modify the twisted tape. The simulated flow and pressure fields generated by the inclined rib-slot element along a twisted tape are correlatively examined with the measured Nusselt numbers and Fanning friction factors. The tilted transverse ribs convert the flow re-circulation cell behind a vertical rib to the solenoidal vor-tex and trip the separated flows. The inclined slots enable the mass, momentum and energy exchanges between the two axial swirls along the two spiral pathways segregated by the twisted tape. These flow mechanisms induced by the twisted tape and the inclined ribs and slots act synergistically to improve the heat transfer performance with the lessened rib-induced form drags. The average Nusselt numbers are raised to 4.2-3.8 time of the Dittus-Boelter values at the expenses of the Fanning friction factor aug-mentations to 32.5-40.2 time of the Blasius levels at the range of Reynolds number between 10,0 0 0 and 50,0 0 0. Compared with the tubular flows enhanced by the ribbed twist tape, the heat transfer enhance-ments caused by the rib-slot element along a twisted tape in a square duct are similarly retained but the reductions in Fanning friction factor are substantial. The resultant aerothermal performance improve-ments achieved by the inclined rib-slot element lighten the prospective applications to heat exchangers involving swirl generators. To assist these applications, the empirical correlations that calculate the aver-age Nusselt number, Fanning friction factor and relative heat transfer power of a square duct enhanced by the twisted tape with the inclined slots and ribs are devised. (c) 2021 Elsevier Ltd. All rights reserved.
引用
收藏
页数:23
相关论文
共 42 条
  • [1] Thermal performance enhancement of laminar flow using compound twisted square duct and variable pitch twisted tape inserts
    Chithra, V. P.
    Jayakumar, V.
    Bakthavatchalam, Balaji
    Kusekar, Sambhaji Kashinath
    Irshad, Kashif
    Habib, Khairul
    CASE STUDIES IN THERMAL ENGINEERING, 2024, 64
  • [2] Numerical Investigation of Solar Air Heater Duct with Square Transverse and Inclined Ribs
    Lad, Gaurav
    Raghuvanshi, Nikhil
    Mehrotra, Pranshu
    Srivastava, Ankur
    ADVANCES IN FLUID AND THERMAL ENGINEERING, 2019, : 445 - 458
  • [3] Enhancement of the Thermohydraulic Performance in a Double Passage Square Duct with the Use of Inclined Ribs of 45°: A Comparative Computational Study
    Kaplan, Mahmut
    INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2024, 2024
  • [4] Thermal and swirl flow topologies in a twisted square duct with a multi-twisted tape installed
    Promthaisong, Pitak
    Chuwattanakul, Varesa
    Eiamsa-Ard, Smith
    JOURNAL OF THERMAL SCIENCE AND TECHNOLOGY, 2020, 15 (01):
  • [5] Laminar flow and heat transfer through square duct with twisted tape insert
    Ray, S
    Date, AW
    INTERNATIONAL JOURNAL OF HEAT AND FLUID FLOW, 2001, 22 (04) : 460 - 472
  • [6] Heat transfer enhancement through a square duct fitted with twisted tape inserts
    S. V. Patil
    P. V. Vijaybabu
    Heat and Mass Transfer, 2012, 48 : 1803 - 1811
  • [7] Heat transfer enhancement through a square duct fitted with twisted tape inserts
    Patil, S. V.
    Vijaybabu, P. V.
    HEAT AND MASS TRANSFER, 2012, 48 (10) : 1803 - 1811
  • [8] Friction and heat transfer characteristics of flow through square duct with twisted tape insert
    Ray, S
    Date, AW
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2003, 46 (05) : 889 - 902
  • [9] Exergetic performance evaluation of SAH with inclined ribs used as coarseness in triangular duct
    Bharadwaj, Gaurav
    Dogra, Sudhanshu
    MATERIALS TODAY-PROCEEDINGS, 2022, 62 : 4455 - 4462
  • [10] Internal Flow in an Enhanced Tube Having Square-cut Twisted Tape Insert
    Wijayanta, Agung Tri
    Pranowo
    Mirmanto
    Kristiawan, Budi
    Aziz, Muhammad
    ENERGIES, 2019, 12 (02)