Developing a dose-volume histogram computation program for brachytherapy

被引:4
|
作者
Panitsa, E [1 ]
Rosenwald, JC
Kappas, C
机构
[1] Univ Patras, Dept Med Phys, Patras 26500, Greece
[2] Inst Curie, Serv Phys Med, F-75005 Paris, France
来源
PHYSICS IN MEDICINE AND BIOLOGY | 1998年 / 43卷 / 08期
关键词
D O I
10.1088/0031-9155/43/8/009
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A dose-volume histogram (DVH) computation program was developed for brachytherapy treatment planning in an attempt to benefit from the DVH's ability to present graphically information on 3D dose distributions. The program is incorporated into a planning system that utilizes a pair of orthogonal radiographs to localize the radiation sources. DVHs are calculated for the volume of tissue enclosed by an isodose sur-face (e.g. half the value of the reference isodose). The calculation algorithm is I,based on a non-uniform random sampling that gives a denser point distribution at the centre of the implants. Our program was tested and proved to be fast enough for clinical use and sufficiently accurate (i.e. computation time of 20 s and less than 2% relative error for one point source, for 100000 calculation points). The accuracy improves when a larger calculation point number is used, but the computation time also increases proportionally. The DVH is presented in the form of a simple graph or table, or as Anderson's 'natural' DVH graph. The cumulative DVH tables can be used to extract a series of indexes characterizing the homogeneity and the dose levels of the distribution in the treatment volume and the surrounding tissues. If a reference plan is available, the DVH results can be assessed relative to the reference plan's DVH.
引用
收藏
页码:2109 / 2121
页数:13
相关论文
共 50 条
  • [21] Development and use of a dose-volume histogram analysis tool
    Bice, W.
    Jurkovic, I.
    Sims, M.
    Prestidge, B.
    MEDICAL PHYSICS, 2006, 33 (06) : 2085 - 2085
  • [22] Data-Driven Dose-Volume Histogram Prediction
    Polizzi, Mitchell
    Watkins, Robert W.
    Watkins, William T.
    ADVANCES IN RADIATION ONCOLOGY, 2022, 7 (02)
  • [23] A NATURAL VOLUME-DOSE HISTOGRAM FOR BRACHYTHERAPY
    ANDERSON, LL
    MEDICAL PHYSICS, 1986, 13 (06) : 898 - 903
  • [24] Defining the risk of developing grade 2 proctitis following 125I prostate brachytherapy using a rectal dose-volume histogram analysis
    Snyder, KM
    Stock, RG
    Hong, SM
    Lo, YC
    Stone, NN
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2001, 50 (02): : 335 - 341
  • [25] Predicting Complication Probabilities Beyond the Dose-Volume Histogram: Dose-Mapping to Identify Critical Dose-Volume Risk Factors
    Deasy, J.
    Saleh, Z.
    Apte, A.
    MEDICAL PHYSICS, 2012, 39 (06) : 3901 - 3901
  • [26] Inverse-planned gynecologic high-dose-rate interstitial brachytherapy: Clinical outcomes and dose-volume histogram analysis
    Thibault, Isabelle
    Lavallee, Marie-Claude
    Aubin, Sylviane
    Laflamme, Nathalie
    Vigneault, Eric
    BRACHYTHERAPY, 2012, 11 (03) : 181 - 191
  • [27] Dose-volume consistency in multicentric study in prostate brachytherapy
    Mangili, P
    RADIOTHERAPY AND ONCOLOGY, 2003, 68 : S13 - S13
  • [28] Dose-volume histogram (DVH) analysis of organs at risk for intracavitary brachytherapy of cervical cancer: Compared to ICRU 38 reference dose
    Kim, RY
    Pareek, PN
    RADIOLOGY, 2002, 225 : 598 - 598
  • [29] A dose-volume analysis of permanent transperineal prostate brachytherapy
    Prestidge, BR
    Bice, WS
    Prete, JJ
    Buchholz, TA
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1997, 39 (02): : 289 - 289
  • [30] Importance of three-dimensional treatment planning and dose-volume histogram analysis in the performance and evaluation of intravascular brachytherapy
    Harrison, LB
    Maehara, A
    Patel, NS
    Weissman, HJ
    Waksman, R
    Mintz, GS
    McMillan, TL
    Pisch, J
    Quon, H
    Yang, N
    Chan, R
    Xie, HC
    Chiu-Tsao, ST
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2001, 37 (02) : 61A - 61A