Fully automatic evaluation of the corneal endothelium from in vivo confocal microscopy

被引:48
|
作者
Selig, Bettina [1 ]
Vermeer, Koenraad A. [2 ]
Rieger, Bernd [3 ]
Hillenaar, Toine [4 ]
Hendriks, Cris L. Luengo [1 ]
机构
[1] Uppsala Univ, Ctr Image Anal, S-75105 Uppsala, Sweden
[2] Rotterdam Ophthalm Inst, Rotterdam, Netherlands
[3] Delft Univ Technol, Dept Imaging Phys, Quantitat Imaging Grp, Delft, Netherlands
[4] Rotterdam Eye Hosp, Rotterdam, Netherlands
来源
BMC MEDICAL IMAGING | 2015年 / 15卷
关键词
Frequency analysis; Stochastic watershed segmentation; Image-based quantification; In vivo imaging; Corneal endothelium; DONOR CORNEAS; CELL-DENSITY; EFFICIENT ALGORITHM; TRANSPLANTATION; RECONSTRUCTION; WATERSHEDS; MORPHOLOGY; IMAGES; SYSTEM;
D O I
10.1186/s12880-015-0054-3
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: Manual and semi-automatic analyses of images, acquired in vivo by confocal microscopy, are often used to determine the quality of corneal endothelium in the human eye. These procedures are highly time consuming. Here, we present two fully automatic methods to analyze and quantify corneal endothelium imaged by in vivo white light slit-scanning confocal microscopy. Methods: In the first approach, endothelial cell density is estimated with the help of spatial frequency analysis. We evaluate published methods, and propose a new, parameter-free method. In the second approach, based on the stochastic watershed, cells are automatically segmented and the result is used to estimate cell density, polymegathism (cell size variability) and pleomorphism (cell shape variation). We show how to determine optimal values for the three parameters of this algorithm, and compare its results to a semi-automatic delineation by a trained observer. Results: The frequency analysis method proposed here is more precise than any published method. The segmentation method outperforms the fully automatic method in the NAVIS software (Nidek Technologies Srl, Padova, Italy), which significantly overestimates the number of cells for cell densities below approximately 1200 mm(-2), as well as previously published methods. Conclusions: The methods presented here provide a significant improvement over the state of the art, and make in vivo, automated assessment of corneal endothelium more accessible. The segmentation method proposed paves the way to many possible new morphometric parameters, which can quickly and precisely be determined from the segmented image.
引用
收藏
页数:15
相关论文
共 50 条
  • [31] Confocal Microscopy of Corneal Stroma and Endothelium After LASIK and PRK
    Amoozadeh, Javad
    Aliakbari, Soheil
    Behesht-Nejad, Amir-Houshang
    Seyedian, Mohammad-Amin
    Rezvan, Bijan
    Hashemi, Hassan
    JOURNAL OF REFRACTIVE SURGERY, 2009, 25 (10) : S963 - S968
  • [32] SPECULAR VERSUS CONFOCAL MICROSCOPY OF THE CORNEAL ENDOTHELIUM - A NEW VIEW
    KAUFMAN, SC
    BEUERMAN, RW
    KAUFMAN, HE
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1994, 35 (04) : 1599 - 1599
  • [33] The Evaluation of Corneal Innervation Using Corneal Confocal Microscopy
    Kovalova, I.
    Horakova, M.
    Vlckova, E.
    Michalec, M.
    Raputova, J.
    Bednarik, J.
    CESKA A SLOVENSKA NEUROLOGIE A NEUROCHIRURGIE, 2017, 80 (01) : 49 - 57
  • [34] In vivo confocal microscopy for evaluation of wound healing following corneal refractive surgery
    Tervo, T
    Moilanen, J
    PROGRESS IN RETINAL AND EYE RESEARCH, 2003, 22 (03) : 339 - 358
  • [35] In vivo biopsy by laser confocal microscopy for evaluation of traumatic recurrent corneal erosion
    Chikama, Tai-ichiro
    Takahashi, Norihisa
    Wakuta, Makiko
    Morishige, Naoyuki
    Nishida, Teruo
    MOLECULAR VISION, 2008, 14 (269-70): : 2333 - 2339
  • [36] Evaluation of corneal stromal changes in vivo after LASIK with confocal microscopy.
    Auzerie, O
    Pisella, PJ
    Bokobza, Y
    Baudouin, C
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2001, 42 (04) : S602 - S602
  • [37] The corneal endothelium in an endotoxin-induced uveitis model:: correlation between in vivo confocal microscopy and immunohistochemistry
    Trinh, Liem
    Brignole-Baudouin, Francoise
    Labbe, Antoine
    Raphael, Mathilde
    Bourges, Jean-Louis
    Baudouin, Christophe
    MOLECULAR VISION, 2008, 14 (136-37): : 1149 - 1156
  • [38] Corneal immune cells: Linking in vivo corneal confocal microscopy and immunohistochemistry
    Colorado, Luisa H.
    Nasrin, Fatema
    Murray, Rachael
    Chinnery, Holly Rose
    Dando, Samantha
    Edwards, Katie
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2024, 65 (07)
  • [39] In Vivo Corneal Confocal Microscopy: Pre- and Post-operative Evaluation in a Case of Corneal Neurotization
    Ebner, Roberto
    Fridrich, Guillermo
    Socolovsky, Mariano
    Luna, Analia
    Oscar Croxatto, Juan
    NEURO-OPHTHALMOLOGY, 2020, 44 (03) : 193 - 196
  • [40] Repeatability of In Vivo Corneal Confocal Microscopy to Quantify Corneal Nerve Morphology
    Petropoulos, Ioannis N.
    Manzoor, Tauseef
    Morgan, Philip
    Fadavi, Hassan
    Asghar, Omar
    Alam, Uazman
    Ponirakis, Georgios
    Dabbah, Mohammad A.
    Chen, Xin
    Graham, James
    Tavakoli, Mitra
    Malik, Rayaz A.
    CORNEA, 2013, 32 (05) : E83 - E89