Bonding to CAD-CAM Composites: An Interfacial Fracture Toughness Approach

被引:43
|
作者
Eldafrawy, M. [1 ]
Ebroin, M. G. [1 ]
Gailly, P. A. [2 ]
Nguyen, J. -F. [3 ,4 ]
Sadoun, M. J. [5 ]
Mainjot, A. K. [1 ,6 ]
机构
[1] Univ Liege ULg, Inst Dent, Dent Biomat Res Unit, 45 Quai G Kurth, B-4020 Liege, Belgium
[2] Univ Liege ULg, Ctr Spatial Liege, Surface Micro & Nano Engn Div, Liege, Belgium
[3] Univ Paris Diderot, UFR Odontol, Paris, France
[4] PSL Res Univ, Chim ParisTech, CNRS, Inst Rech Chim Paris, Paris, France
[5] MaJEB Sprl, Liege, Belgium
[6] Univ Liege Hosp CHU, Inst Dent, Dept Fixed Prosthodont, Liege, Belgium
关键词
dental materials; dental prosthesis retention; resin cement; surface properties; ceramics; dental adhesives; CAD/CAM MATERIALS; RESTORATIVE MATERIALS; RESIN; STRENGTH; PRESSURE; CEMENTS; BLOCKS;
D O I
10.1177/0022034517728714
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
The objective of this study was to evaluate the interfacial fracture toughness (IFT) of composite cement with dispersed filler (DF) versus polymer-infiltrated ceramic network (PICN) computer-aided design and computer-aided manufacturing (CAD-CAM) composite blocks after 2 different surface pretreatments using the notchless triangular prism (NTP) test. Two DFs (Cerasmart [CRT] and Lava Ultimate [LVA]), 2 PICNs (Enamic [ENA] and experimental PICN [EXP]), and e.max CAD lithium disilicate glass-ceramic (EMX, control) prism samples were bonded to their counterparts with Variolink Esthetic DC composite cement after either hydrofluoric acid etching (HF) or gritblasting (GR). Both procedures were followed by silanization. All samples (n = 30 per group) were thermocycled (10,000 cycles) and tested for their IFT in a water bath at 36 degrees C. Moreover, representative samples from each group were subjected to a developed interfacial area ratio (Sdr) measurement by profilometry and scanning electron microscopy (SEM) characterization. EXP-HF gave the highest IFT (1.85 +/- 0.39 MPa.m(1/2)), followed by EMX-HF and ENA-HF, while CRT-HF gave the lowest (0.15 +/- 0.22 MPa.m(1/2)). PICNs gave significantly better results with HF, and DF showed better results with GR. A 2-way analysis of variance indicated that there were significantly higher IFT and Sdr for PICNs than for DF. A positive correlation (r(2) = 0.872) was found between IFT and Sdr. SEM characterization showed the specific microstructure of the surface of etched PICNs, indicating the presence of a retentive polymer-based honeycomb structure. Etching of the typical double-network microstructure of PICNs causes an important increase in the Sdr and IFT, while DF should be gritblasted. DF exhibited significantly lower Sdr and IFT values than PICNs. The present results show the important influence of the material class and surface texture, and consequently the micromechanical bond, on the adhesive interface performance of CAD-CAM composites.
引用
收藏
页码:60 / 67
页数:8
相关论文
共 50 条
  • [41] CAD-CAM IN THE YEAR 2000
    MARTIN, RL
    MANUFACTURING ENGINEERING, 1987, 99 (06): : 43 - 49
  • [42] IS CAD-CAM TAKING OFF
    不详
    MACHINE DESIGN, 1975, 47 (14) : 20 - &
  • [43] From Artisanal to CAD-CAM Blocks: State of the Art of Indirect Composites
    Mainjot, A. K.
    Dupont, N. M.
    Oudkerk, J. C.
    Dewael, T. Y.
    Sadoun, M. J.
    JOURNAL OF DENTAL RESEARCH, 2016, 95 (05) : 487 - 495
  • [44] Assessment of interfacial fracture toughness in concrete composites
    Buyukozturk, Oral
    Lee, Kwang-Myong
    Cement and Concrete Composites, 1993, 15 (03) : 143 - 151
  • [45] Effect of thermal cycling on fracture toughness of CAD/CAM materials
    Porto, Thiago Soares
    Roperto, Renato Cassio
    Akkus, Anna
    Akkus, Ozan
    Teich, Sorin
    Faddoul, Fady F.
    Porto-Neto, Sizenando de Toledo
    de Campos, Edson Alves
    AMERICAN JOURNAL OF DENTISTRY, 2018, 31 (04): : 205 - 210
  • [46] Interfacial Fracture Toughness Measurement of Composite/metal Bonding
    Kim, Won-Seock
    Lee, Jung-Ju
    COMPOSITES RESEARCH, 2008, 21 (04): : 7 - 14
  • [47] Energy dissipation capacities of CAD-CAM restorative materials: A comparative evaluation of resilience and toughness
    Niem, Thomas
    Youssef, Nivin
    Woestmann, Bernd
    JOURNAL OF PROSTHETIC DENTISTRY, 2019, 121 (01): : 101 - 109
  • [48] Fracture toughness of chairside CAD/CAM materials - Alternative loading approach for compact tension test
    Badawy, Rania
    El-Mowafy, Omar
    Tam, Laura E.
    DENTAL MATERIALS, 2016, 32 (07) : 847 - 852
  • [50] Fracture strength of composite and all-ceramic CAD-CAM crowns.
    Attia, A.
    Kern, M.
    JOURNAL OF DENTAL RESEARCH, 2003, 82 : B181 - B181