Polyviologen modified glassy carbon electrode employed for anodic stripping voltammetric determination of mercury(II)

被引:27
|
作者
Cheng, Kuan-Chiao [1 ]
Chen, Po-Yu [1 ]
机构
[1] Kaohsiung Med Univ, Fac Med & Appl Chem, Kaohsiung 807, Taiwan
关键词
polyviologen; modified electrode; mercury; anodic stripping; electropolymerization;
D O I
10.1002/elan.200704041
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this study, a polyviologen modified glassy carbon electrode (PVGCE) was used to detect Hg(II) in aqueous solutions containing significant amounts of chloride anions in order to demonstrate the electroanalytical application of the electropolymerized polyviologen. The polyviologen thin film was formed on the electrode surface by applying a constant potertial of - 1.0 V in the pH 4.2 Britton - Robinson (BR) buffer solution that contains 0.1 wt% of viologen oligomers. The PVGCE was found capability to improve the detection limit of Hg(II) in the solutions with high concentration of chloride because Hg(II) forms negative complex ions HgCl42- that can be accumulated to PVGCE by the anion-exchange characteristic of polyviologen. With 5 minutes accumulation at - 0.2 V, the adsorbed HgCl24- anions were reduced to Hg and deposited on the electrode surface, and were determined with the following anodic stripping differential pulse voltammetry (ASDPV). The dependence of anodic stripping current versus concentration was linear from 1 ppb (5 nM) to 100 ppb (0.5 mu M) with a regression coefficient of 0.9959.
引用
收藏
页码:207 / 210
页数:4
相关论文
共 50 条
  • [41] Determination of trace metoclopramide by anodic stripping voltammetry with nafion modified glassy carbon electrode
    Wang, ZH
    Zhang, HZ
    Zhou, SP
    Dong, WJ
    TALANTA, 2001, 53 (06) : 1133 - 1138
  • [42] Anodic stripping voltammetric determination of arsenic(III) using a glassy carbon electrode modified with gold-palladium bimetallic nanoparticles
    Lan, Yuecun
    Luo, Hanjin
    Ren, Xiaohui
    Wang, Yiping
    Liu, Yuze
    MICROCHIMICA ACTA, 2012, 178 (1-2) : 153 - 161
  • [43] Selenium-coated carbon electrode for anodic stripping voltammetric determination of copper(II)
    Nagaosa, Yukio
    Zong, Ping
    Kamio, Akihiro
    MICROCHIMICA ACTA, 2009, 167 (3-4) : 241 - 246
  • [44] Selenium-coated carbon electrode for anodic stripping voltammetric determination of copper(II)
    Yukio Nagaosa
    Ping Zong
    Akihiro Kamio
    Microchimica Acta, 2009, 167 : 241 - 246
  • [45] Anodic stripping voltammetric determination of arsenic(III) using a glassy carbon electrode modified with gold-palladium bimetallic nanoparticles
    Yuecun Lan
    Hanjin Luo
    Xiaohui Ren
    Yiping Wang
    Yuze Liu
    Microchimica Acta, 2012, 178 : 153 - 161
  • [46] Differential Pulse Anodic Stripping Voltammetric Determination of Cadmium(II) at a Glassy Carbon Electrode Modified with a Nano-TiO2/Chitosan Composite Film
    Xie, Zhimin
    Fei, Junjie
    Huang, Meihua
    AUSTRALIAN JOURNAL OF CHEMISTRY, 2008, 61 (12) : 1000 - 1005
  • [47] ANODIC-STRIPPING VOLTAMMETRIC DETERMINATION OF ARSENIC AT A COPPER-COATED GLASSY-CARBON ELECTRODE
    JAYA, S
    RAO, TP
    RAO, GP
    TALANTA, 1987, 34 (06) : 574 - 576
  • [48] Electrochemistry and Adsorptive Stripping Voltammetric Determination of Amoxicillin on a Multiwalled Carbon Nanotubes Modified Glassy Carbon Electrode
    Rezaei, Behzad
    Damiri, Sajjad
    ELECTROANALYSIS, 2009, 21 (14) : 1577 - 1586
  • [49] Stripping voltammetric determination of mercury(II) at antimony-coated carbon paste electrode
    Ashrafi, Amir M.
    Vytras, Karel
    TALANTA, 2011, 85 (05) : 2700 - 2702
  • [50] Voltammetric Determination of Arsenic with Modified Glassy Carbon Electrode
    Stankovic, Anamarija
    Kajinic, Zana
    Turkalj, Jelena Vesligaj
    Romic, Zeljka
    Sikiric, Maja Dutour
    Asserghine, Abdelilah
    Nagy, Geza
    Medvidovic-Kosanovic, Martina
    ELECTROANALYSIS, 2020, 32 (05) : 1043 - 1051