Transient elastography for the noninvasive assessment of liver fibrosis: A multicentre Canadian study

被引:63
|
作者
Myers, Robert P. [1 ]
Elkashab, Magdy [3 ]
Ma, Mang [2 ]
Crotty, Pam [1 ]
Pomier-Layrargues, Gilles [4 ]
机构
[1] Univ Calgary, Liver Unit, Div Gastroenterol, Dept Med, Calgary, AB T2N 4N1, Canada
[2] Univ Alberta, Dept Med, Div Gastroenterol, Edmonton, AB, Canada
[3] Toronto Liver Ctr, Toronto, ON, Canada
[4] CHU Montreal, Liver Unit, Hop St Luc, Montreal, PQ, Canada
关键词
Biopsy; Cirrhosis; Elastography; Fatty liver; Fibrosis; Hepatitis; OPERATING CHARACTERISTIC CURVES; C-RELATED FIBROSIS; STIFFNESS MEASUREMENT; SAMPLING VARIABILITY; VIRUS-INFECTION; DIAGNOSTIC-TEST; MARKERS; BIOPSY; REPRODUCIBILITY; PERFORMANCE;
D O I
10.1155/2010/153986
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
BACKGROUND: Liver stiffness measurement (LSM) using transient elastography (TE) is a promising tool for the noninvasive assessment of hepatic fibrosis. OBJECTIVES: To determine the feasibility and performance of TE in a North American cohort of patients with chronic liver disease. METHODS: LSMs were obtained using TE in 260 patients with chronic hepatitis B or C, or nonalcoholic fatty liver disease from four Canadian hepatology centres. The accuracy of TE compared with liver biopsy for the prediction of significant fibrosis (Metavir fibrosis score of F2 or greater), bridging fibrosis (Metavir fibrosis score of F3 or greater) and cirrhosis (Meravir fibrosis score of F4) was assessed using area under ROC curves (AUROCs), and compared with the aspartate aminotransferase-to-platelet ratio index. The influence of alanine aminotransferase (ALT) levels and other factors on liver stiffness was determined using linear regression analyses. RESULTS: Failure of TE occurred in 2.7% of patients, while liver biopsies were inadequate for staging in 0.8%. Among the remaining 251 patients, the AUROCs of TE for Metavir fibrosis scores of F2 and F3 or greater, and F4 were 0.74 (95% CI 0.68 to 0.80), 0.89 (95% CI 0.84 to 0.94), and 0.94 (95% CI 0.90 to 0.97), respectively. LSM was more accurate than the aminotransferase-to-platelet ratio index for bridging fibrosis (AUROC 0.78) and cirrhosis (AUROC 0.88), but not significant fibrosis (AUROC 0.76). At a cut-off of 11.1 kPa, the sensitivity, specificity, and positive and negative predictive values for cirrhosis (prevalence 11%) were 96%, 81%, 39% and 99%, respectively. For significant fibrosis (prevalence 53%), a cut-off of 7.7 kPa was 68% sensitive and 69% specific, and had a positive predictive value of 70% and a negative predictive value of 65%. Liver stiffness was independently associated with ALT, body mass index and steatosis. The optimal LSM cut-offs for cirrhosis were 11.1kPa and 11.5 kPa in patients with ALT levels lower than 100 U/L and 100 U/L or greater, respectively. For fibrosis scores of F2 or greater, these figures were 7.0 kPa and 8.6 kPa, respectively. CONCLUSIONS: The major role of TE is the exclusion of bridging fibrosis and cirrhosis. However, TE cannot replace biopsy for the diagnosis of significant fibrosis. Because liver stiffness may be influenced by significant ALT elevation, body mass index and/or steatosis, tailored liver stiffness cut-offs may be necessary to account for these factors.
引用
收藏
页码:661 / 670
页数:10
相关论文
共 50 条
  • [41] Assessment of liver fibrosis using transient elastography in patients with alcoholic liver disease
    Nahon, Pierre
    Kettaneh, Adrien
    Tengher-Barna, Iulia
    Ziol, Marianne
    de Ledinghen, Victor
    Douvin, Catherine
    Marcellin, Patrick
    Ganne-Carrie, Nathalie
    Trinchet, Jean-Claude
    Beaugrand, Michel
    JOURNAL OF HEPATOLOGY, 2008, 49 (06) : 1062 - 1068
  • [42] Noninvasive methods, including transient elastography, for the detection of liver disease in adults with cystic fibrosis
    Sadler, Matthew D.
    Crotty, Pam
    Fatovich, Linda
    Wilson, Stephanie
    Rabin, Harvey R.
    Myers, Robert P.
    CANADIAN JOURNAL OF GASTROENTEROLOGY AND HEPATOLOGY, 2015, 29 (03): : 139 - 144
  • [43] Noninvasive Imaging Test to Assess Liver Fibrosis: Vibration-controlled Transient Elastography
    Kim, Mi Na
    KOREAN JOURNAL OF GASTROENTEROLOGY, 2024, 84 (05): : 201 - 205
  • [44] Transient elastography for the diagnosis of liver fibrosis
    de Ledinghen, Victor
    Vergniol, Julien
    EXPERT REVIEW OF MEDICAL DEVICES, 2010, 7 (06) : 811 - 823
  • [45] Noninvasive Detection of liver fibrosis with multiparametric Magnetic Resonance Imaging compared to Transient Elastography
    Dyvorne, Hadrien
    Jajamovich, Guido H.
    Fiel, M. Isabel
    Friedman, Scott L.
    Dieterich, Douglas T.
    Donnerhack, Claudia
    Ehman, Richard
    Taouli, Bachir
    HEPATOLOGY, 2013, 58 : 962A - 963A
  • [46] Transient Elastography Is a Useful Noninvasive Tool for the Evaluation of Fibrosis in Paediatric Chronic Liver Disease
    Fitzpatrick, Emer
    Quaglia, Alberto
    Vimalesvaran, Sunitha
    Basso, Maria Sole
    Dhawan, Anil
    JOURNAL OF PEDIATRIC GASTROENTEROLOGY AND NUTRITION, 2013, 56 (01): : 72 - 76
  • [47] Performance and utility of transient elastography and noninvasive markers of liver fibrosis in primary biliary cirrhosis
    Floreani, Annarosa
    Cazzagon, Nora
    Martines, Diego
    Cavalletto, Luisa
    Baldo, Vincenzo
    Chemello, Liliana
    DIGESTIVE AND LIVER DISEASE, 2011, 43 (11) : 887 - 892
  • [48] Transient elastography for liver fibrosis diagnosis
    Andersen, Ellen Sloth
    Christensen, Peer Brehm
    Weis, Nina
    EUROPEAN JOURNAL OF INTERNAL MEDICINE, 2009, 20 (04) : 339 - 342
  • [49] Noninvasive Pediatric Liver Fibrosis Measurement: Two-Dimensional Shear Wave Elastography Compared With Transient Elastography
    Tran, Lea Chantal
    Ley, Delphine
    Bourdon, Gurvan
    Coopman, Stephanie
    Lerisson, Heloise
    Tillaux, Celine
    Behal, Helene
    Gottrand, Frederic
    Aumar, Madeleine
    FRONTIERS IN PEDIATRICS, 2022, 10
  • [50] Advanced Fibrosis in Nonalcoholic Fatty Liver Disease: Noninvasive Assessment with MR Elastography
    Kim, Donghee
    Kim, W. Ray
    Talwalkar, Jayant A.
    Kim, Hwa Jung
    Ehman, Richard L.
    RADIOLOGY, 2013, 268 (02) : 411 - 419