Pilot study of personal, indoor and outdoor exposure to benzene, formaldehyde and acetaldehyde

被引:32
|
作者
Gonzalez-Flesca, N
Cicolella, A
Bates, M
Bastin, E
机构
[1] INERIS, Parc Technol ALATA, F-60550 Verneuil En Halatte, France
[2] Univ Hertfordshire, Hatfield AL10 9AB, Herts, England
[3] AIRLOR, F-54500 Vandoeuvre Nancy, France
关键词
acetaldehyde; benzene; chronic exposure; diffusive sampling; formaldehyde; health risk assessment; indoor air quality; personal exposure; roadside air quality; thermal desorption; urban environment;
D O I
10.1007/BF02987560
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
There is a lack of data for health risk assessment of long term personal exposure to certain ubiquitous air pollutants present particularly in urban atmospheres. The relationship between ambient background concentrations and personal exposure is often unknown. A pilot campaign to measure indoor concentrations, outdoor concentrations and personal exposure to benzene, formaldehyde and acetaldehyde was conducted in a medium sized French town. A strong contribution to total personal exposure was observed from indoor sources, especially for formaldehyde and acetaldehyde, suggesting that indoor sources are dominant for these compounds. For benzene, the average personal exposure exceeded a 10 mu gm(-3) limit value, although this was not the case for the ambient background concentration. For formaldehyde, the limit level was also exceeded. Observations suggest that true personal exposure cannot be determined directly from measurements pertaining from fixed ambient background monitoring stations. It is hoped that this will be taken into consideration by the bodies responsible for monitoring air pollution and the future European Air Quality Directive.
引用
收藏
页码:95 / 102
页数:8
相关论文
共 50 条
  • [31] Spatial and temporal variability in outdoor, indoor, and personal PM2.5 exposure
    Adgate, JL
    Ramachandran, G
    Pratt, GC
    Waller, LA
    Sexton, K
    ATMOSPHERIC ENVIRONMENT, 2002, 36 (20) : 3255 - 3265
  • [32] Formaldehyde exposure in a gross anatomy laboratory - Personal exposure level is higher than indoor concentration
    Ohmichi, K
    Komiyama, M
    Matsuno, Y
    Takanashi, Y
    Miyamoto, H
    Kadota, T
    Maekawa, M
    Toyama, Y
    Tatsugi, Y
    Kohno, T
    Ohmichi, M
    Mori, C
    ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH, 2006, 13 (02) : 120 - 124
  • [33] The RIOPA (Relationship among Indoor, Outdoor and Personal Air) study
    Weisel, CP
    Colome, S
    Morandi, M
    Stock, T
    Spektor, D
    Turpin, B
    Zhang, J
    EPIDEMIOLOGY, 1999, 10 (04) : S92 - S92
  • [34] Personal exposure to indoor aerosols as actual concern: Perceived indoor and outdoor air quality, and health performances
    Oh, Hyeon-Ju
    Jeong, Na-Na
    Sohn, Jong-Ryeul
    Kim, Jongbok
    BUILDING AND ENVIRONMENT, 2019, 165
  • [35] Personal exposure to fine particulate matter in elderly subjects: Relation between personal, indoor, and outdoor concentrations
    Janssen, NAH
    de Hartog, JJ
    Hoek, G
    Brunekreef, B
    Lanki, T
    Timonen, KL
    Pekkanen, J
    JOURNAL OF THE AIR & WASTE MANAGEMENT ASSOCIATION, 2000, 50 (07) : 1133 - 1143
  • [36] EXPOSURE TO FORMALDEHYDE IN INDOOR AIR
    GAMMAGE, RB
    RISK ANALYSIS, 1990, 10 (01) : 77 - 83
  • [37] Characterisation of urban inhalation exposures to benzene, formaldehyde and acetaldehyde in the European UnionComparison of measured and modelled exposure data
    Yuri Bruinen de Bruin
    Kimmo Koistinen
    Stylianos Kephalopoulos
    Otmar Geiss
    Salvatore Tirendi
    Dimitrios Kotzias
    Environmental Science and Pollution Research, 2008, 15 : 417 - 430
  • [38] Windsor, Ontario Exposure Assessment Study: Design and Methods Validation of Personal, Indoor, and Outdoor Air Pollution Monitoring
    Wheeler, Amanda J.
    Xu, Xiaohong
    Kulka, Ryan
    You, Hongyu
    Wallace, Lance
    Mallach, Gary
    Van Ryswyk, Keith
    MacNeill, Morgan
    Kearney, Jill
    Dabek-Zlotorzynska, Ewa
    Wang, Daniel
    Poon, Raymond
    Williams, Ron
    Stocco, Corinne
    Anastassopoulos, Angelos
    Miller, J. David
    Dales, Robert
    Brook, Jeffrey R.
    JOURNAL OF THE AIR & WASTE MANAGEMENT ASSOCIATION, 2011, 61 (02) : 142 - 156
  • [39] Windsor, Ontario Exposure Assessment Study: Design and Methods Validation of Personal, Indoor, and Outdoor Air Pollution Monitoring
    Wheeler, Amanda J.
    Xu, Xiaohong
    Kulka, Ryan
    You, Hongyu
    Wallace, Lance
    Mallach, Gary
    Van Ryswyk, Keith
    MacNeill, Morgan
    Kearney, Jill
    Rasmussen, Pat E.
    Dabek-Zlotorzynska, Ewa
    Wang, Daniel
    Poon, Raymond
    Williams, Ron
    Stocco, Corinne
    Anastassopoulos, Angelos
    Miller, J. David
    Dales, Robert
    Brook, Jeffrey R.
    JOURNAL OF THE AIR & WASTE MANAGEMENT ASSOCIATION, 2011, 61 (03) : 324 - 338
  • [40] Outdoor, indoor, and personal black carbon exposure from cookstoves burning solid fuels
    Downward, G. S.
    Hu, W.
    Rothman, N.
    Reiss, B.
    Wu, G.
    Wei, F.
    Xu, J.
    Seow, W. J.
    Brunekreef, B.
    Chapman, R. S.
    Qing, L.
    Vermeulen, R.
    INDOOR AIR, 2016, 26 (05) : 784 - 795