Voltammetric determination of promethazine by platinum and glassy carbon electrodes

被引:0
|
作者
Uslu, B
Biryol, I
Ozkan, SA
Senturk, Z
机构
关键词
promethazine; voltammetry; platinum and glassy carbon electrodes;
D O I
暂无
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
The electrochemical oxidation of promethazine was studied by linear sweep and cyclic voltammetry on platinum and glassy carbon electrodes. The dependence of current intensities and potentials on pH, concentration, scan rate and nature of the buffer was examined. Linear calibration plots were obtained in phosphate buffer (pH 7.0) and acetate buffer (pH 4.7) for platinum and glassy carbon electrode, respectively.
引用
收藏
页码:323 / 328
页数:6
相关论文
共 50 条
  • [1] Voltammetric determination of salbutamol based on electrochemical oxidation at platinum and glassy carbon electrodes
    Yilmaz, N
    Ozkan, SA
    Uslu, B
    Senturk, Z
    Biryol, I
    TURKISH JOURNAL OF CHEMISTRY, 1998, 22 (02): : 175 - 182
  • [2] Determination of imipramine hydrochloride in drages based on voltammetric oxidation with platinum and activated glassy carbon electrodes
    Uslu, B
    Biryol, I
    STP PHARMA SCIENCES, 1997, 7 (03): : 248 - 253
  • [3] Voltammetric determination of promethazine hydrochloride at a multi-wall carbon nanotube modified glassy carbon electrode
    Xi, Xia
    Ming, Liang
    Liu, Jie
    DRUG TESTING AND ANALYSIS, 2011, 3 (03) : 182 - 186
  • [4] Differential pulse voltammetric determination of chlorphenoxamine hydrochloride and its pharmaceutical preparations using platinum and glassy carbon electrodes
    Abdel-Ghani, Nour T.
    Abu-Elenien, Gouda M.
    Hussein, Salwa H.
    JOURNAL OF APPLIED ELECTROCHEMISTRY, 2010, 40 (03) : 499 - 505
  • [5] Differential pulse voltammetric determination of chlorphenoxamine hydrochloride and its pharmaceutical preparations using platinum and glassy carbon electrodes
    Nour T. Abdel-Ghani
    Gouda M. Abu-Elenien
    Salwa H. Hussein
    Journal of Applied Electrochemistry, 2010, 40 : 499 - 505
  • [6] Glassy carbon and boron doped glassy carbon electrodes for voltammetric determination of linuron herbicide in the selected samples
    Dordevic, Jelena S.
    Kalijadis, Ana M.
    Kumric, Ksenija R.
    Jovanovic, Zoran M.
    Lausevic, Zoran V.
    Trtic-Petrovic, Tatjana M.
    CENTRAL EUROPEAN JOURNAL OF CHEMISTRY, 2012, 10 (04): : 1271 - 1279
  • [7] Simple and rapid voltammetric determination of morphine at electrochemically pretreated glassy carbon electrodes
    Li, Fei
    Song, Jixia
    Gao, Dongmei
    Zhang, Qixian
    Han, Dongxue
    Niu, Li
    TALANTA, 2009, 79 (03) : 845 - 850
  • [8] Voltammetric determination of atenolol at C60-modified glassy carbon electrodes
    Goyal, Rajendra N.
    Singh, Sudhanshu P.
    TALANTA, 2006, 69 (04) : 932 - 937
  • [9] Electrochemical Behavior of Trazodone at Mercury and Glassy Carbon Electrodes and Voltammetric Methods for its Determination
    Kacar, C.
    Durmus, Z.
    Kilic, E.
    ASIAN JOURNAL OF CHEMISTRY, 2014, 26 (07) : 1931 - 1937
  • [10] ELECTROCHEMICAL BEHAVIOR OF MOCLOBEMIDE AT MERCURY AND GLASSY CARBON ELECTRODES AND VOLTAMMETRIC METHODS FOR ITS DETERMINATION
    Erdogan, Deniz Altinoz
    Tasdemir, Ibrahim Hudai
    Erk, Nevin
    Kilic, Esma
    COLLECTION OF CZECHOSLOVAK CHEMICAL COMMUNICATIONS, 2011, 76 (05) : 423 - 442