Compact fluidic electrochemical sensor platform for on-line monitoring of chemical oxygen demand in urban wastewater

被引:17
|
作者
Duan, Wenchao [1 ,2 ]
Gunes, Murat [2 ]
Baldi, Antonio [2 ]
Gich, Marti [1 ]
Fernandez-Sanchez, Cesar [2 ,3 ]
机构
[1] ICMAB CSIC, Inst Ciencia Mat Barcelona, Campus UAB, Bellaterra 08193, Spain
[2] IMB CNM CSIC, Inst Microelect Barcelona, Campus UAB, Bellaterra 08193, Spain
[3] GIBER Bioingn Biomat & Nanomed CIBER BBN, Jordi Girona 18-26, Barcelona 08034, Spain
关键词
Carbon-silica thin-film electrode; Sol-gel; Electrochemical sensor; Chemical oxygen demand; Modular fluidic system; ELECTRODE; REDUCTION; KINETICS;
D O I
10.1016/j.cej.2022.137837
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The rapid expansion of urban areas has given rise to the generation of large amounts of wastewater that pose a growing pressure on the surrounding ecosystems. Effective water quality surveillance programs demand the implementation of in-field tests to monitor water safe discharge in the environment after being adequately treated. This paper describes the manufacturing and application of a miniaturized electrochemical sensor for measuring dissolved chemical oxygen demand (COD) in surface waters entering and exiting urban wastewater treatment plants (UWWTP). Thin-film carbon electrodes are produced on Si/SiO2 substrates by a combined sol-gel material synthesis and photolithography/dry etching process at the wafer level and show superior electrochemical performance compared with the glassy carbon standard electrode. Three-electrode electrochemical cells of planar configuration are produced and the COD sensor is manufactured by electrodepositing copper nanoparticles (Cu NPs) on the working electrode under controlled potentiostatic conditions. A simple fluidic electrochemical sensor device is fabricated and allows for the Cu NPs electrodeposition as well as analytical sensor performance in an automatic fashion. A linear range up to 670 mg.L-1 O-2 and a limit of detection of 30 mg.L-1 O-2 are achieved. The ability of this electrochemical sensor approach to monitoring the soluble organic load of urban wastewater in real-time is evaluated by analyzing three samples collected in different locations of an UWWTP. The COD values estimated with the sensor are in excellent agreement with those obtained using the standard dichromate method provided by an accredited laboratory. This analytical platform provides a robust, user-friendly low-maintenance flow sensor approach for deployed analysis of COD that could aid to control the effectiveness of water treatment processes, especially when facing water influents containing organic overloads due to changing weather conditions or any anthropogenic phenomena.
引用
收藏
页数:11
相关论文
共 50 条
  • [31] A nano-lead dioxide-composite electrochemical sensor for the determination of chemical oxygen demand
    Wang, Xi
    Wu, Dandan
    Yuan, Du
    Wu, Xu
    JOURNAL OF ENVIRONMENTAL CHEMICAL ENGINEERING, 2022, 10 (03):
  • [32] Microfluidic Electrochemical Sensor for Online Detection of Chemical Oxygen Demand Based on AuNPs/Au Electrodes
    Xie, Song
    Wu, Haotian
    Yang, Xiaozhan
    IEEE Sensors Journal, 2024, 24 (23) : 38584 - 38588
  • [33] Performance of an electrochemical COD (chemical oxygen demand) sensor with an electrode-surface grinding unit
    Jeong, Bong Geun
    Yoon, Seok Min
    Choi, Chang Ho
    Kwon, Kil Koang
    Hyun, Moon Sik
    Yi, Dong Heui
    Park, Hyung Soo
    Kim, Mia
    Kim, Hyung Joo
    JOURNAL OF ENVIRONMENTAL MONITORING, 2007, 9 (12): : 1352 - 1357
  • [34] A sensor for on-line nondestructive monitoring of the diffusion layer depth in metals subjected to chemical heat treatment
    Godlevskii, VA
    Maurin, DL
    INDUSTRIAL LABORATORY, 1999, 65 (02): : 104 - 107
  • [35] In situ and on-line monitoring of cadmium in soil pore water using an automatic sampling integrated electrochemical sensor
    KUANG JiaJie
    WEN JunLin
    CAI XiXi
    ZHOU LiHua
    YUAN Yong
    Science China(Technological Sciences), 2024, 67 (09) : 2894 - 2904
  • [36] In situ and on-line monitoring of cadmium in soil pore water using an automatic sampling integrated electrochemical sensor
    Kuang, Jiajie
    Wen, Junlin
    Cai, Xixi
    Zhou, Lihua
    Yuan, Yong
    SCIENCE CHINA-TECHNOLOGICAL SCIENCES, 2024, 67 (09) : 2894 - 2904
  • [37] Implementation of an automatic and miniature on-line multi-parameter water quality monitoring system and experimental determination of chemical oxygen demand and ammonia-nitrogen
    Xie, Yingke
    Wen, Zhiyu
    Mo, Zhihong
    Yu, Zhiqiang
    Wei, Kanglin
    WATER SCIENCE AND TECHNOLOGY, 2016, 73 (03) : 697 - 706
  • [38] A miniature photoelectrochemical sensor based on organic electrochemical transistor for sensitive determination of chemical oxygen demand in wastewaters
    Liao, Jianjun
    Lin, Shiwei
    Zeng, Min
    Yang, Yue
    WATER RESEARCH, 2016, 94 : 296 - 304
  • [39] Chemical oxygen demand (COD) sensor using a stopped-flow thin layer electrochemical cell
    Res. Ctr. for Adv. Sci. and Technol., University of Tokyo, 4-6-1 Komaba, Meguro, Tokyo 153-8904, Japan
    不详
    Electroanalysis, 1600, 16 (1172-1179):
  • [40] Preparation of Electrochemical Sensor Based on Morphology-Controlled Platinum Nanoparticles for Determination of Chemical Oxygen Demand
    Wu Can
    Wu Kang-Bing
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2013, 41 (05) : 704 - 708