Efficiency calibrations of cylindrically bent transmission crystals in the 20 to 80 keV x-ray energy range

被引:16
|
作者
Szabo, Csilla I. [4 ]
Feldman, Uri [4 ]
Seltzer, Stephen [4 ]
Hudson, Lawrence T. [3 ]
O'Brien, Michelle [3 ]
Park, Hye-Sook [2 ]
Seely, John F. [1 ]
机构
[1] USN, Res Lab, Div Space Sci, Washington, DC 20036 USA
[2] Lawrence Livermore Natl Lab, Livermore, CA 94550 USA
[3] NIST, Gaithersburg, MD 20899 USA
[4] Artep Inc, Ellicott City, MD 21042 USA
关键词
SPECTROGRAPHY;
D O I
10.1364/OL.36.001335
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Two quartz (10-11) crystals were cylindrically bent to a 25: 4 cm radius of curvature and were mounted in identical Cauchois-type transmission spectrometers, and the crystal diffraction efficiencies were measured to 5% absolute accuracy using narrow bandwidth x-ray source fluences in the 20 to 80 keV energy range. The measured integrated reflectivity values were compared to calculations performed using a computational model that accounts for the diffraction geometry of the bent transmission crystal. These crystal calibrations enable the accurate measurement of absolute hard x- ray emission levels from laser- produced plasmas and other laboratory sources.
引用
收藏
页码:1335 / 1337
页数:3
相关论文
共 50 条
  • [21] BALLOON OBSERVATION OF X-RAY SOURCES IN CYGNUS REGION IN ENERGY RANGE 20-130 KEV
    BLEEKER, JAM
    BURGER, JJ
    DEERENBE.AJ
    SCHEEPMA.A
    SWANENBU.BN
    TANAKA, Y
    ASTROPHYSICAL JOURNAL, 1967, 147 (01): : 391 - &
  • [22] SOLEX:: a tunable monochromatic X-ray source in the 1-20 keV energy range for metrology
    Bonnelle, C
    Jonnard, P
    André, JM
    Avila, A
    Laporte, D
    Ringuenet, H
    Lépy, MC
    Plagnard, J
    Ferreux, L
    Protas, JC
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2004, 516 (2-3): : 594 - 601
  • [23] X-RAY SUVEY OF NORTHERN SKY OBSERVATION OF SPECTRA IN ENERGY RANGE FROM 20 TO 100 KEV
    LEWIN, WHG
    CLARK, GW
    SMITH, WB
    ASTRONOMICAL JOURNAL, 1967, 72 (07): : 812 - &
  • [24] HIGH-INTENSITY TRANSMISSION X-RAY TOPOGRAPHY OF HOMOGENEOUSLY BENT CRYSTALS
    MEIERAN, ES
    BLECH, IA
    JOURNAL OF APPLIED PHYSICS, 1972, 43 (02) : 265 - &
  • [25] X-ray diffraction efficiency of bent GaAs mosaic crystals for the Laue project
    Ferrari, Claudio
    Buffagni, Elisa
    Bonnini, Elisa
    Zappettini, Andrea
    OPTICAL ENGINEERING, 2014, 53 (04)
  • [26] X-ray diffraction efficiency of bent GaAs mosaic crystals for the LAUE project
    Ferrari, C.
    Buffagni, E.
    Bonnini, E.
    Zappettini, A.
    OPTICS FOR EUV, X-RAY, AND GAMMA-RAY ASTRONOMY VI, 2013, 8861
  • [27] DIAGNOSTICS OF BENT X-RAY DIAGNOSTIC CRYSTALS
    Pereira, N. R.
    Macrander, A. T.
    Stoupin, S.
    Baronova, E. O.
    2015 42ND IEEE INTERNATIONAL CONFERENCE ON PLASMA SCIENCES (ICOPS), 2015,
  • [28] VOXES: a high precision X-ray spectrometer for diffused sources with HAPG crystals in the 2-20 keV range
    Scordo, A.
    Curceanu, C.
    Miliucci, M.
    Shi, H.
    Sirghi, F.
    Zmeskal, J.
    JOURNAL OF INSTRUMENTATION, 2018, 13
  • [29] Energy dispersion of X-ray continua in the energy range 8 keV to 16 keV by refraction on Si wafers
    Ebel, H
    Streli, C
    Pepponi, G
    Wobrauschek, P
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2001, 56 (11) : 2045 - 2048
  • [30] EFFICIENCY DETERMINATION OF A SI(LI) X-RAY-DETECTOR IN THE ENERGY-RANGE 1-20 KEV
    TRIBEDI, LC
    TANDON, PN
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1992, 69 (2-3): : 178 - 181