Predictive value of specimen radiography for core needle biopsy of noncalcified breast masses

被引:19
|
作者
Berg, WA
Jaeger, B
Campassi, C
Kumar, D
机构
[1] Univ Maryland, Sch Med, Dept Radiol, Baltimore, MD 21201 USA
[2] Univ Maryland, Sch Med, Greenebaum Canc Ctr, Baltimore, MD 21201 USA
[3] Univ Maryland, Sch Med, Dept Pathol, Baltimore, MD 21201 USA
关键词
D O I
10.2214/ajr.171.6.9843311
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. Our objective was to determine the predictive value of specimen radiography for large core (14-gauge) needle biopsy of noncalcified breast masses. SUBJECTS AND METHODS. Eighty-four biopsies of 83 breast masses yielded 403 specimens. Specimens showing dense material on specimen radiography were predicted to be diagnostic; specimens showing intermediate- or low-density material were predicted to be nondiagnostic. Specimen radiographic and histopathologic findings were correlated for each specimen using vital dyes to mark individual specimens. RESULTS. Of the 403 specimens, 307 (76%) contained diagnostic material representative of the lesion, with a specific diagnosis achieved for 82 (99%) of 83 lesions (62 benign, 20 malignant). Of the 293 passes containing dense material, 268 (91%) proved to be diagnostic; 11 (18%) of 62 specimens containing only low-density material proved to be diagnostic. Of the 25 (9%) of 293 specimens containing radiographically dense but nondiagnostic material, 18 (72%) showed focal fibrosis and had missed the lesion; 15 (83%) of 18 such specimens were obtained in dense parenchyma. The positive predictive value of specimen radiography was 13 (100%) of 13 in fatty breasts; 77 (96%) of 80 in breasts with minimal scattered fibroglandular elements; 91 (94%) of 97 in heterogeneously dense breasts; and 35 (70%) of 50 in breasts with extremely dense parenchyma. Of the 16 lesions sampled stereotactically, specimen radiography helped assess the inadequacy of initial sampling in three (19%). In six (9%) of 68 sonographically guided biopsies, only one or two specimens could be obtained; specimen radiography helped us predict whether material was adequate for diagnosis. CONCLUSION. Radiography of core specimens obtained from noncalcified breast masses accurately reveals the adequacy of sampling unless the breast parenchyma is extremely dense. Such immediate assessment can help ensure adequate material from lesions that are difficult to biopsy and can thereby improve the diagnostic yield of large core needle breast biopsy.
引用
收藏
页码:1671 / 1678
页数:8
相关论文
共 50 条
  • [21] A comparison of fine needle aspiration cytology (FNAC) and core needle biopsy in the evaluation of breast masses
    Westenend, PJ
    Sever, A
    Liem, SJ
    JOURNAL OF PATHOLOGY, 2001, 193 : 6A - 6A
  • [22] Histologic grading at breast core needle biopsy: Comparison with results from the excised breast specimen
    Monticciolo, DL
    BREAST JOURNAL, 2005, 11 (01): : 9 - 14
  • [24] A comparison of fine needle aspiration cytology and core biopsy in the diagnosis of breast masses
    Ahiskali, Rengin
    Tosuner, Zeynep
    Tuzuner, Burcu
    Kaya, Handan
    Gulluoglu, Bahadir
    Aribal, Erkin
    VIRCHOWS ARCHIV, 2007, 451 (02) : 115 - 115
  • [25] Core needle biopsy of anterior mediastinum masses
    Boaron, M
    Artuso, S
    Lacava, N
    Santelmo, N
    Sartini, M
    Poletti, V
    Cancellieri, A
    Baruzzi, G
    EPITHELIAL TUMORS OF THE THYMUS: PATHOLOGY, BIOLOGY, TREATMENT, 1997, : 293 - 298
  • [26] Expression and Subtype Discordance Between Core Needle Biopsy and Surgical Specimen in Breast Cancer
    Xu, Min
    Yan, Yiwei
    Chen, Yueqin
    Chen, Xiaobin
    Gong, Kai
    Fu, Fangmeng
    JOURNAL OF SURGICAL RESEARCH, 2025, 307 : 42 - 52
  • [27] Neoadjuvant therapy in breast cancer: scoring system with predictive value of pathologic response obtained in core needle biopsy
    Aranda Ignacio, F.
    Peiro, G.
    Niveiro, M.
    Alcaraz, E.
    Adrover, E.
    Muci, T.
    Segui, J.
    Alenda, C.
    VIRCHOWS ARCHIV, 2009, 455 : 182 - 182
  • [28] Value of phenotype in invasive breast carcinoma evaluated by needle core biopsy
    Aranda Lopez, E. Ignacio
    Abuomar, Adel
    Peiro, Gloria
    Planelles, Maria
    Alcaraz, Eduardo
    Niveiro, Maria
    Segui, Javier
    VIRCHOWS ARCHIV, 2008, 452 : S150 - S150
  • [29] Negative Predictive Value of Transthoracic Core-Needle Biopsy A Multicenter Study
    Fontaine-Delaruelle, Clara
    Souquet, Pierre-Jean
    Gamondes, Delphine
    Pradat, Eric
    De Leusse, Aurelie
    Ferretti, Gilbert R.
    Couraud, Sebastien
    CHEST, 2015, 148 (02) : 472 - 480
  • [30] NEEDLE ASPIRATION BIOPSY OF PALPABLE BREAST MASSES
    KAHKY, MP
    RONE, VR
    DUNCAN, DL
    CRUZ, AB
    GASKILL, HV
    AMERICAN JOURNAL OF SURGERY, 1988, 156 (06): : 450 - 452