Design Aspects of Focal Beams From High-Intensity Arrays

被引:22
|
作者
Stephens, Douglas N. [1 ]
Kruse, Dustin E. [1 ]
Qin, Shengping [1 ]
Ferrara, Katherine W.
机构
[1] Univ Calif Davis, Dept Biomed Engn, Davis, CA 95616 USA
关键词
ULTRASOUND PHASED-ARRAY; TISSUE; OPTIMIZATION; HYPERTHERMIA; FEASIBILITY; TRANSDUCER; SIMULATION; ABLATION; PATTERN; SURGERY;
D O I
10.1109/TUFFC.2011.1986
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
As the applications of ultrasonic thermal therapies expand, the design of the high-intensity array must address both the energy delivery of the main beam and the character and relevance of off-target beam energy. We simulate the acoustic field performance of a selected set of circular arrays organized by array format, including flat versus curved arrays, periodic versus random arrays, and center void diameter variations. Performance metrics are based on the -3-dB focal main lobe (FML) positioning range, axial grating lobe (AGL) temperatures, and side lobe levels. Using finite-element analysis, we evaluate the relative heating of the FML and the AGLs. All arrays have a maximum diameter of 100 lambda, with element count ranging from 64 to 1024 and continuous wave frequency of 1.5 MHz. First, we show that a 50% spherical annulus produces focus beam side lobes which decay as a function of lateral distance at nearly 87% of the exponential rate of a full aperture. Second, for the arrays studied, the efficiency of power delivery over the -3-dB focus positioning range for spherical arrays is at least 2-fold greater than for flat arrays; the 256-element case shows a 5-fold advantage for the spherical array. Third, AGL heating can be significant as the focal target is moved to its distal half-intensity depth from the natural focus. Increasing the element count of a randomized array to 256 elements decreases the AGL-to-FML heating ratio to 0.12 at the distal half-intensity depth. Further increases in element count yield modest improvements. A 49% improvement in the AGL-to-peak heating ratio is predicted by using the Sumanaweera spiral element pattern with randomization.
引用
收藏
页码:1590 / 1602
页数:13
相关论文
共 50 条
  • [31] Gaussian representation of high-intensity focused ultrasound beams
    Soneson, Joshua E.
    Myers, Matthew R.
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2007, 122 (05): : 2526 - 2531
  • [32] GENERATION AND ACCELERATION OF HIGH-INTENSITY BEAMS IN THE SLC INJECTOR
    ROSS, MC
    BROWNE, MJ
    CLENDENIN, JE
    JOBE, RK
    SEEMAN, JT
    SHEPPARD, JC
    STIENING, RF
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1985, 32 (05) : 3160 - 3162
  • [33] Particle trapping and transportation by high-intensity singular beams
    Izdebskaya, YV
    Shvedov, VG
    Alexeyev, CN
    Volyar, AV
    NONLINEAR OPTICS OF LIQUID AND PHOTOREFRACTIVE CRYSTALS, 2003, 5257 : 313 - 316
  • [34] ISR NEW ABSORBER BLOCKS FOR HIGH-INTENSITY BEAMS
    HAUVILLER, C
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1979, 24 (02): : 182 - 182
  • [35] NEW ISR ABSORBER BLOCKS FOR HIGH-INTENSITY BEAMS
    HAUVILLER, C
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1979, 26 (03) : 4134 - 4136
  • [36] PROPORTIONAL WIRE CHAMBERS IN HIGH-INTENSITY PARTICLE BEAMS
    INYAKIN, AV
    KACHANOV, VA
    KOSTROMIN, PP
    PATALAKHA, DI
    PROKOSHKIN, YD
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 1977, 20 (01) : 27 - 29
  • [37] Electron dynamics for high-intensity hollow electron beams
    Rossi, A.
    Nikiforov, D.
    Arsentyeva, M.
    Barnyakov, A.
    Levichev, A.
    JOURNAL OF INSTRUMENTATION, 2021, 16 (03)
  • [38] Hamiltonian formalism for halo investigation in high-intensity beams
    Senichev, Yu.
    Vasyukhin, N.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2006, 561 (02): : 166 - 172
  • [39] Development of a transmittance monitor for high-intensity photon beams
    Matsumura, Y.
    Ishikawa, T.
    Honda, Y.
    Kido, S.
    Miyabe, M.
    Nagasawa, I.
    Nanbu, K.
    Shimizu, H.
    Takahashi, K.
    Tsuchikawa, Y.
    Yamazaki, H.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2018, 902 : 103 - 109
  • [40] HIGH-INTENSITY CESIUM ION BEAMS FOR HIBP DIAGNOSTICS
    Krupnik, L., I
    Barcala, J.
    Chmyga, O. O.
    Deshko, G. M.
    Drabinskiy, M. A.
    Eliseev, L. G.
    Hidalgo, C.
    Khabanov, Ph O.
    Kharchev, N. K.
    Khrebtov, S. M.
    Komarov, O. D.
    Kozachok, O. S.
    Melnikov, A., V
    Molinero, A.
    de Pablos, J. L.
    PROBLEMS OF ATOMIC SCIENCE AND TECHNOLOGY, 2020, (06): : 190 - 194