Investigating the effect of micro-riblets on the flow and micro-mixing behavior in micro-channel

被引:3
|
作者
Ling, Fiona W. M. [1 ,2 ]
Khleif, Ali A. [3 ]
Abdulbari, Hayder A. [1 ,2 ]
机构
[1] Univ Malaysia Pahang, Ctr Excellence Adv Res Fluid Flow CARIFF, Gambang 26300, Pahang, Malaysia
[2] Univ Malaysia Pahang, Fac Chem & Nat Resources Engn, Gambang, Pahang, Malaysia
[3] Univ Technol IRAQ, Dept Prod Engn & Met, Baghdad, Iraq
关键词
Micro-riblets; mixing; passive micro-mixer; mu-PIV; DRAG REDUCTION; PASSIVE MICROMIXER; OPTIMIZATION; OBSTACLES; SIMULATION; DESIGN; BLADES; LAYOUT; MIXER;
D O I
10.1080/00986445.2020.1715959
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
Chaotic advection method is usually implemented to design any micro-mixing device, specifically micro-mixers, where the base or the top wide surface is structured for maximum mixing performance. This method comes with several drawbacks, such as the high-pressure drop caused by the structured inner surface. In the present work, V-shaped micro-riblets with the riblets size ranged between 20 and 100 mu m are designed and structured on the side-walls of a rectangular T-shaped micro-mixers to test its mixing and flow enhancement performances at different flow rates for single and multiple phases flow. The micro-mixers were fabricated using a direct writing method with polydimethylsiloxane as a substrate. The flow and mixing behaviors of single and multiphase flow systems were investigated through monitoring the flow of the fluids flowing through the system using micro-Particle Image Velocimetry (mu-PIV). The results showed a flow enhancement up to similar to 29% for a 60 mu m of base-to-height riblet at an operating pressure of similar to 200 mbar for a single-phase flow system. Larger micro-riblets were found to produce a thicker laminar sub-layer within the devices that narrowed the active core of the solution. When a two-phase flow system is introduced, the flow enhancement was observed in the water phase at operating pressure > 600 mbar and riblets dimension > 60 mu m. On the other hand, the maximum mixing intensity of 52% was observed in 60 mu m micro-riblets size indicating that the presence of micro-structure in the micro-mixer can enhance both the flow and mixing efficiency.
引用
收藏
页码:673 / 686
页数:14
相关论文
共 50 条
  • [21] Micro-mixing in chemical reactors: A perspective
    Mao, Zaisha
    Yang, Chao
    CHINESE JOURNAL OF CHEMICAL ENGINEERING, 2017, 25 (04) : 381 - 390
  • [22] Fluid flow in a micro-channel: A stochastic approach
    Black, HM
    Nassar, R
    Dai, WZ
    MICROMACHINING AND MICROFABRICATION PROCESS TECHNOLOGY VII, 2001, 4557 : 233 - 241
  • [23] Micro-mixing in chemical reactors:A perspective
    Zaisha Mao
    Chao Yang
    Chinese Journal of Chemical Engineering, 2017, 25 (04) : 381 - 390
  • [24] Light-actuated electrothermal microfluidic flow for micro-mixing
    Lee, Seunghyun
    Kim, Jupyoung
    Wereley, Steven T.
    Kwon, Jae-Sung
    JOURNAL OF MICROMECHANICS AND MICROENGINEERING, 2019, 29 (01)
  • [25] Simulation of subcooled flow boiling in a micro-channel
    Rui Zhuan
    Wen Wang
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2011, 34 (03): : 781 - 795
  • [26] PIV analysis of turbulent flow in a micro-channel
    Blonski, Slawomir
    Kowalewski, Tomasz A.
    JOURNAL OF THEORETICAL AND APPLIED MECHANICS, 2007, 45 (03) : 489 - 503
  • [27] Research on flow velocity field in jagged micro-channel with micro-PIV
    Wang, Yuan
    Jin, Wen
    He, Wenbo
    Hsi-An Chiao Tung Ta Hsueh/Journal of Xi'an Jiaotong University, 2009, 43 (09): : 109 - 113
  • [28] Flow analysis of micro-channel in injection molding
    Wu, Cheng-Hsien
    Wu, Shih-Min
    JOURNAL OF POLYMER ENGINEERING, 2007, 27 (02) : 107 - 127
  • [29] The golden-mean surface pattern to enhance flow mixing in micro-channel
    Wang, J. F.
    Liu, Y.
    Xu, Y. S.
    BIOMEDICAL MICRODEVICES, 2009, 11 (02) : 351 - 357
  • [30] The golden-mean surface pattern to enhance flow mixing in micro-channel
    J. F. Wang
    Y. Liu
    Y. S. Xu
    Biomedical Microdevices, 2009, 11 : 351 - 357