Influence of the number and position of stripped screws on plate-screw construct biomechanical properties

被引:1
|
作者
Garces, Gerardo L. [1 ]
Yanez, Alejandro [2 ]
Cuadrado, Alberto [2 ]
Martel, Oscar [2 ]
机构
[1] Univ Las Palmas Gran Canaria, Orthopaed Surg, Dept Med & Surg Sci, Las Palmas Gran Canaria, Spain
[2] Univ Las Palmas Gran Canaria, Dept Mech Engn, Las Palmas Gran Canaria, Spain
关键词
screw stripping; stiffness; plate-screw construct; DYNAMIC COMPRESSION PLATE; ANKLE FRACTURE FIXATION; OSTEOPOROTIC BONE; LOCKING ELEMENTS; STRAIN; STRENGTH; MODEL; STABILITY; STIFFNESS; SYSTEM;
D O I
10.1016/S0020-1383(17)30795-7
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Introduction: Screw stripping is a common situation in fracture fixation, particularly in osteopenic bone treatment. Surgeons' perception of screw stripping is relatively poor and the real number of loose screws in every plate-screw construct is unknown. The biomechanical and clinical implications of the different possible screw-stripping situations are also unidentified. In this study, construct stiffness in different scenarios of stripped screws is investigated. Method: A bone surrogate comminuted osteoporotic fracture was fixed with four screws in both sides of the fracture gap in 75 specimens. In four groups, one or two screws closest or distal to the gap were over-tightened and left in place in one part of the construct and the remaining screws were tightened with 0.3 N m torque (four groups). In the fifth group (control), all the screws were tightened with 0.3 N m torque. Construct stiffness was tested in terms of compression, bending, and torsion for 1000 cycles. Results: When one or two screws closest to the gap were stripped, stiffness only decreased by, respectively, 5.7% or 7.6% under compression and 4.7% or 6.7% under bending; however, stiffness in torsion was 15.1% or 32%, respectively, lower than the initial stiffness. When a screw distal to the gap was stripped, the stiffness decreased by 28% under bending and 10% under compression; no change was noted under torsion. When two screws distal to the gap were stripped, the stiffness decreased by 11% in compression, collapsed under bending, and decreased by 8% under torsion. Conclusions: Position and number of stripped screws affect the biomechanical properties of a construct in different ways, depending on the acting forces. (c) 2017 Elsevier Ltd. All rights reserved.
引用
收藏
页码:S54 / S59
页数:6
相关论文
共 50 条
  • [1] Biomechanical Comparison of Screw Versus Plate/Screw Construct for Talonavicular Fusion
    Jarrell, Shelby E.
    Owen, John R.
    Wayne, Jennifer S.
    Adelaar, Robert S.
    FOOT & ANKLE INTERNATIONAL, 2009, 30 (02) : 150 - 156
  • [2] Biomechanical evaluation of peak reverse torque (PRT) in a dynamic compression plate-screw construct used in a goat tibia segmental defect model
    Remigiusz M. Grzeskowiak
    Carrie Wheeler
    Elizabeth Taylor
    James Lillich
    James Roush
    Alexandru S. Biris
    David E. Anderson
    BMC Veterinary Research, 15
  • [3] Biomechanical comparison of plate-screw and screw fixation in medial tibial plateau fractures (Schatzker 4). A model study
    Cift, H.
    Cetik, O.
    Kalaycioglu, B.
    Dirikoglu, M. H.
    Ozkan, K.
    Eksioglu, F.
    ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2010, 96 (03) : 263 - 267
  • [4] Biomechanical evaluation of peak reverse torque (PRT) in a dynamic compression plate-screw construct used in a goat tibia segmental defect model
    Grzeskowiak, Remigiusz M.
    Wheeler, Carrie
    Taylor, Elizabeth
    Lillich, James
    Roush, James
    Biris, Alexandru S.
    Anderson, David E.
    BMC VETERINARY RESEARCH, 2019, 15 (01) : 321
  • [5] Biomechanical comparison of titanium alloy additively manufactured and conventionally manufactured plate-screw constructs
    Polak, S.
    Beever, L.
    Wade, A.
    Fukuoka, M.
    Worth, A. J.
    NEW ZEALAND VETERINARY JOURNAL, 2024, 72 (01) : 17 - 27
  • [6] Cortical screws used to rescue failed lumbar pedicle screw construct: a biomechanical analysis
    Calvert, Graham C.
    Lawrence, Brandon D.
    Abtahi, Amir M.
    Bachus, Kent N.
    Brodke, Darrel S.
    JOURNAL OF NEUROSURGERY-SPINE, 2015, 22 (02) : 166 - 172
  • [7] Stability of Locking Plate and Compression Screws for Lapidus Arthrodesis: A Biomechanical Comparison of Plate Position
    Drummond, David
    Motley, Travis
    Kosmopoulos, Victor
    Ernst, Jordan
    JOURNAL OF FOOT & ANKLE SURGERY, 2018, 57 (03): : 466 - 470
  • [8] Does the position of a sustentacular screw influence the stability of a plate osteosynthesis of a calcaneal fracture? A biomechanical study
    Pazour, Jan
    Horak, Zdenek
    Dzupa, Valer
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2021, 235 (09) : 993 - 1000
  • [9] The Position and Number of Screws Influence Screw Perforation of the Humeral Head in Modern Locking Plates: A Cadaver Study
    Erhardt, Johannes B.
    Stoffel, Karl
    Kampshoff, Jorg
    Badur, Nicole
    Yates, Piers
    Kuster, Markus S.
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2012, 26 (10) : E188 - E192
  • [10] Clinical, Biomechanical and Biomaterials Approach in the Case of Fracture Repair Using Different Systems Type Plate-Screw
    Ionescu, Razvan
    Cristescu, Ioan
    Dinu, Mihaela
    Saban, Rami
    Antoniac, Iulian
    Vilcioiu, Dan
    BIOMMEDD V, 2014, 583 : 150 - +