A Review of Infrared Thermography for Condition-Based Monitoring in Electrical Energy: Applications and Recommendations

被引:30
|
作者
Balakrishnan, Ganesh Kumar [1 ]
Yaw, Chong Tak [2 ]
Koh, Siaw Paw [2 ]
Abedin, Tarek [2 ]
Raj, Avinash Ashwin [3 ]
Tiong, Sieh Kiong [2 ]
Chen, Chai Phing [4 ]
机构
[1] Wisma TNB, 19 Jalan Timur, Petaling Jaya 46200, Selangor, Malaysia
[2] Natl Energy Univ, Inst Sustainable Energy, Jalan Ikram Uniten, Kajang 43000, Selangor, Malaysia
[3] TNBR Sdn Bhd, Kawasan Inst Penyelidikan Bandar Baru Bangi, 1 Lorong Air Hitam, Kajang 43000, Selangor, Malaysia
[4] Natl Energy Univ, Dept Elect & Elect Engn, Jalan Ikram Uniten, Kajang 43000, Selangor, Malaysia
关键词
condition-based monitoring; diagnosis; fault detection; infrared thermography; non-destructive; INTER-TURN FAULT; INDUCTION-MOTORS; THERMAL-ANALYSIS; REAL-TIME; DIAGNOSIS; STATOR; IMAGE; EQUIPMENT; SEGMENTATION; RELIABILITY;
D O I
10.3390/en15166000
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Condition-based monitoring (CBM) has emerged as a critical instrument for lowering the cost of unplanned operations while also improving the efficacy, execution, and dependability of tools. Thermal abnormalities can be thoroughly examined using thermography for condition monitoring. Thanks to the advent of high-resolution infrared cameras, researchers are paying more attention to thermography as a non-contact approach for monitoring the temperature rise of objects and as a technique in great experiments to analyze processes thermally. It also allows for the early identification of weaknesses and failures in equipment while it is in use, decreasing system downtime, catastrophic failure, and maintenance expenses. In many applications, the usage of IRT as a condition monitoring approach has steadily increased during the previous three decades. Infrared cameras are steadily finding use in research and development, in addition to their routine use in condition monitoring and preventative maintenance. This study focuses on infrared crucial thermographic theoretical stages, experimental methodologies, relative and absolute temperature requirements, and infrared essential thermographic theoretical processes for electrical and electronics energy applications. Furthermore, this article addresses the major concerns and obstacles and makes some specific recommendations for future development. With developments in artificial intelligence, particularly computer fiction, depending on the present deep learning algorithm, IRT can boost CBM analysis.
引用
收藏
页数:37
相关论文
共 50 条
  • [21] MONITORING THE CONDITION OF VEGETABLES, FRUITS AND PLANTS USING INFRARED THERMOGRAPHY
    Dunaevsky, V
    Venher, Y.
    Liptyha, A.
    Kotovskyi, V
    Timofeyev, V
    Nazarchuk, S.
    JOURNAL OF FOOD SCIENCE AND TECHNOLOGY-UKRAINE, 2020, 14 (04): : 98 - 104
  • [22] Condition monitoring utilising infrared thermography in a power generation environment
    Day, R
    INSIGHT, 2005, 47 (09) : 547 - 550
  • [23] Recent Industrial Applications of Infrared Thermography: A Review
    Alfredo Osornio-Rios, Roque
    Alfonso Antonino-Daviu, Jose
    de Jesus Romero-Troncoso, Rene
    IEEE TRANSACTIONS ON INDUSTRIAL INFORMATICS, 2019, 15 (02) : 615 - 625
  • [24] A Review of Infrared Thermography Applications for Civil Infrastructure
    Shrestha, Prabal
    Avci, Onur
    Rifai, Sahabeddin
    Abla, Feras
    Seek, Michael
    Barth, Karl
    Halabe, Udaya
    SDHM Structural Durability and Health Monitoring, 19 (02): : 193 - 231
  • [25] A Sensor Reduced Machine Learning Approach for Condition-based Energy Monitoring for Machine Tools
    Sossenheimer, Johannes
    Walther, Jessica
    Fleddermann, Jan
    Abele, Eberhard
    52ND CIRP CONFERENCE ON MANUFACTURING SYSTEMS (CMS), 2019, 81 : 570 - 575
  • [26] Condition-based maintenance implementation: a literature review
    Teixeira, Humberto Nuno
    Lopes, Isabel
    Braga, Ana Cristina
    30TH INTERNATIONAL CONFERENCE ON FLEXIBLE AUTOMATION AND INTELLIGENT MANUFACTURING (FAIM2021), 2020, 51 : 228 - 235
  • [27] UTILIZATION OF CMS (CONDITION MONITORING SYSTEM) FOR CBM (CONDITION-BASED MAINTENANCE)
    Morota, Hidetsugu
    Miyazono, Toshimitsu
    Okumura, Tatsuro
    ICONE 17: PROCEEDINGS OF THE 17TH INTERNATIONAL CONFERENCE ON NUCLEAR ENGINEERING, VOL 1, 2009, : 179 - 185
  • [28] Thermal Condition Monitoring of Electrical Installations Based on Infrared Image Analysis
    Jadin, Mohd Shawal
    Ghazali, Kamarul Hawari
    Taib, Soib
    2013 SAUDI INTERNATIONAL ELECTRONICS, COMMUNICATIONS AND PHOTONICS CONFERENCE (SIECPC), 2013,
  • [29] Automated Condition-Based Monitoring of Automated People Movers
    Fong, Stanley
    Ashasi-Sorkhabi, Ali
    Prakash, Guru
    Narasimhan, Sriram
    Riseborough, Mike
    AUTOMATED PEOPLE MOVERS AND AUTOMATED TRANSIT SYSTEMS 2018: MOVING TO THE FUTURE, BUILDING ON THE PAST, 2018, : 57 - 67
  • [30] Condition-based maintenance: Cylinder pressure monitoring in newbuilding
    Anon
    Diesel and Gas Turbine Worldwide, 2001, 33 (03):