Wideband Phase Refractive Indices and Group Index Measurement of Liquid Samples with low Coherent Fabry-Perot Interferometry

被引:0
|
作者
Bang, David J. [1 ]
Kim, Yudeuk [1 ]
Kim, Yoohan [1 ]
Kim, Myung-Jik [1 ]
Kim, Kyong Hon [1 ]
机构
[1] Inha Univ, Dept Phys, 100 Inha Ro, Incheon 22212, South Korea
基金
新加坡国家研究基金会;
关键词
Interferometry; Fabry-Perot; Nondestructive testing; Optical constants; Interference; Fourier filtering;
D O I
暂无
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
We present a simple method allowing simultaneous measurement of group and phase refractive indices of liquid samples by using low coherence Fabry-Perot (FP) interferometry and Fourier transform (FT) analysis. The liquid sample was placed in a very thin cuvettes and located within a fiber-type FP interferometer with a broad-band light source of 1.5 mu m wavelength region. The interference spectrum of the FP interferometer including the liquid sample was measured with an optical spectrum analyzer (OSA), and Fourier transform analysis on the spectrum was performed to determine the sample's refractive index profile over a broad spectral range. Our measurement method was proved by measuring the refractive index profile of a pure water. The accuracy of this method was within third decimal point for both the group refractive index and the phase refractive indices.
引用
收藏
页码:250 / 253
页数:4
相关论文
共 50 条
  • [31] Gold Enhanced Hemoglobin Interaction in a Fabry-Perot Based Optical Fiber Sensor for Measurement of Blood Refractive Index
    Viphavakit, Charusluk
    O'Keeffe, Sinead
    Yang, Minghong
    Andersson-Engels, Stefan
    Lewis, Elfed
    JOURNAL OF LIGHTWAVE TECHNOLOGY, 2018, 36 (04) : 1118 - 1124
  • [32] Fabry-Perot Cavity Based on a High-Birefringent Fiber Bragg Grating for Refractive Index and Temperature Measurement
    Gouveia, C.
    Jorge, P. A. S.
    Baptista, J. M.
    Frazao, O.
    IEEE SENSORS JOURNAL, 2012, 12 (01) : 17 - 21
  • [33] Temperature-insensitive miniaturized fiber inline Fabry-Perot interferometer for highly sensitive refractive index measurement
    Wei, Tao
    Han, Yukun
    Li, Yanjun
    Tsai, Hai-Lung
    Xiao, Hai
    OPTICS EXPRESS, 2008, 16 (08): : 5764 - 5769
  • [34] Hetero-core structured Fabry-Perot fiber sensor for liquid refractive index and Hydrogen gas detection
    Hashimoto, Mizuki
    Hosoki, Ai
    Nishiyama, Michiko
    Watanabe, Kazuhiro
    2015 9TH INTERNATIONAL CONFERENCE ON SENSING TECHNOLOGY (ICST), 2015, : 325 - 328
  • [35] Temperature-compensated multi-point refractive index sensing based on a cascaded Fabry-Perot cavity and FMCW interferometry
    Zhu, Zongda
    Ba, Dexin
    Liu, Lu
    Qiu, Liqiang
    Yang, Shunhu
    Dong, Yongkang
    OPTICS EXPRESS, 2021, 29 (12): : 19034 - 19048
  • [36] Absolute Measurement of Dynamic Low-Finesse Fabry-Perot Cavity Using Phase-Shifting White-Light Interferometry
    Liu, Qiang
    Jing, Zhenguo
    Liu, Yueying
    Li, Ang
    Xia, Zhenjie
    Peng, Wei
    JOURNAL OF LIGHTWAVE TECHNOLOGY, 2021, 39 (12) : 3926 - 3931
  • [37] Novel Compact and Low-Cost Ultraweak Fabry-Perot Interferometer as a Highly Sensitive Refractive Index Sensor
    Chen, Pengcheng
    Shu, Xuewen
    Cao, Haoran
    IEEE PHOTONICS JOURNAL, 2017, 9 (05):
  • [38] Corneal group refractive index measurement using low-coherence interferometry
    Uhlhorn, SR
    Manns, F
    Tahi, H
    Rol, P
    Parel, JM
    OPHTHALMIC TECHNOLOGIES VIII, PROCEEDINGS OF, 1998, 3246 : 14 - 21
  • [39] A Highly Sensitive Fiber-Optic Fabry-Perot Interferometer Based on Internal Reflection Mirrors for Refractive Index Measurement
    Li, Xuefeng
    Shao, Yujiao
    Yu, Yuan
    Zhang, Yin
    Wei, Shaowen
    SENSORS, 2016, 16 (06):
  • [40] Air cavity-based Fabry-Perot interferometer sensor fabricated using a sawing technique for refractive index measurement
    Jung, Eun Joo
    Lee, Woo-Jin
    Kim, Myoung Jin
    Hwang, Sung Hwan
    Rho, Byung Sup
    OPTICAL ENGINEERING, 2014, 53 (01) : 1V