A deep-learning reconstruction algorithm that improves the image quality of low-tube-voltage coronary CT angiography

被引:26
|
作者
Wang, Mengzhen [1 ]
Fan, Jing [1 ]
Shi, Xiaofeng [1 ]
Qin, Le [1 ]
Yan, Fuhua [1 ]
Yang, Wenjie [1 ]
机构
[1] Shanghai Jiao Tong Univ, Sch Med, Ruijin Hosp, Dept Radiol, Shanghai, Peoples R China
基金
中国国家自然科学基金;
关键词
Coronary computed tomography angiography; Deep learning; Low tube voltage; Image reconstruction; ITERATIVE RECONSTRUCTION; COMPUTED-TOMOGRAPHY; NOISE-REDUCTION; ABDOMINAL CT; MULTICENTER;
D O I
10.1016/j.ejrad.2021.110070
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To assess the image quality (IQ) of low tube voltage coronary CT angiography (CCTA) images reconstructed with deep learning image reconstruction (DLIR). Methods: According to body mass index (BMI), eighty patients who underwent 70kVp CCTA (Group A, N = 40, BMI <= 26 kg/m2) or 80kVp CCTA (Group B, N = 40, BMI > 26 kg/m2) were prospectively included. All images were reconstructed with four algorithms, including filtered back-projection (FBP), adaptive statistical iterative reconstruction-Veo at a level of 50% (ASiR-V50%), and DLIR at medium (DLIR-M) and high (DLIR-H) levels. Image noise, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR) and edge rise distance (ERD) within aorta root and coronary arteries were calculated. The IQ was subjectively evaluated by using a 5-point scale. Results: Compared with FBP, ASiR-V50% and DLIR-M, DLIR-H led to the lowest noise (Group A: 24.7 +/- 5.0HU; Group B, 21.6 +/- 2.8 HU), highest SNR (Group A, 24.9 +/- 5.0; Group B, 28.0 +/- 5.8), CNR (Group A, 42.2 +/- 15.2; Group B, 43.6 +/- 10.5) and lowest ERD (Group A, 1.49 +/- 0.30 mm; Group B, 1.50 +/- 0.22 mm) with statistical significance (all P < 0.05). For the objective assessment, the percentages of 4 and 5 IQ scores were significantly higher for DLIR-H (Group A, 93.8%; Group B,90.0%) and DLIR-M (Group A, 85.6%; Group B,86.9 %) compared to ASiR-V50% (Group A, 58.8%; Group B, 58.8%) and FBP (Group A, 34.4%; Group B, 33.1%) algorithms (all P < 0.05). Conclusion: The application of DLIR significantly improves both objective and subjective IQ in low tube voltage CCTA compared with ASiR-V and FBP, which may promote a further radiation dose reduction in CCTA.
引用
收藏
页数:9
相关论文
共 50 条
  • [41] Low-dose liver CT: image quality and diagnostic accuracy of deep learning image reconstruction algorithm
    Damiano Caruso
    Domenico De Santis
    Antonella Del Gaudio
    Gisella Guido
    Marta Zerunian
    Michela Polici
    Daniela Valanzuolo
    Dominga Pugliese
    Raffaello Persechino
    Antonio Cremona
    Luca Barbato
    Andrea Caloisi
    Elsa Iannicelli
    Andrea Laghi
    European Radiology, 2024, 34 : 2384 - 2393
  • [42] Impact of an artificial intelligence deep-learning reconstruction algorithm for CT on image quality and potential dose reduction: A phantom study
    Greffier, Joel
    Si-Mohamed, Salim
    Frandon, Julien
    Loisy, Maeliss
    de Oliveira, Fabien
    Beregi, Jean Paul
    Dabli, Djamel
    MEDICAL PHYSICS, 2022, 49 (08) : 5052 - 5063
  • [43] 60KV COMBINED DEEP LEARNING RECONSTRUCTION ALGORITHM FOR AORTIC CT ANGIOGRAPHY: A PROMISING ALGORITHM FOR IMAGE QUALITY IMPROVEMENT?
    Yang, Xiaofei
    Li, Mingxin
    Chen, Yan
    Yue, Songwei
    Gao, Jianbo
    CHEST, 2024, 166 (04) : 4063A - 4063A
  • [44] Deep Learning Reconstruction Improves the Image Quality of CT Angiography Derived From 80-kVp Cerebral CT Perfusion Data
    Chen, Yu
    Wang, Yanling
    Su, Tong
    Xu, Min
    Yan, Jing
    Wang, Jian
    Liu, Haozhe
    Lu, Xiaoping
    Wang, Yun
    Jin, Zhengyu
    ACADEMIC RADIOLOGY, 2023, 30 (11) : 2666 - 2673
  • [45] Super-resolution deep-learning reconstruction with 1024 matrix improves CT image quality for pancreatic ductal adenocarcinoma assessment
    Nagayama, Yasunori
    Ishiuchi, Soichiro
    Inoue, Taihei
    Funama, Yoshinori
    Shigematsu, Shinsuke
    Emoto, Takafumi
    Sakabe, Daisuke
    Ueda, Hiroko
    Chiba, Yutaka
    Ito, Yuya
    Kidoh, Masafumi
    Oda, Seitaro
    Nakaura, Takeshi
    Hirai, Toshinori
    EUROPEAN JOURNAL OF RADIOLOGY, 2025, 184
  • [46] Comparison of image quality of two versions of deep-learning image reconstruction algorithm on a rapid kV-switching CT: a phantom study
    Dabli, Djamel
    Loisy, Maeliss
    Frandon, Julien
    de Oliveira, Fabien
    Meerun, Azhar Mohamad
    Guiu, Boris
    Beregi, Jean-Paul
    Greffier, Joel
    EUROPEAN RADIOLOGY EXPERIMENTAL, 2023, 7 (01)
  • [47] Comparison of image quality of two versions of deep-learning image reconstruction algorithm on a rapid kV-switching CT: a phantom study
    Djamel Dabli
    Maeliss Loisy
    Julien Frandon
    Fabien de Oliveira
    Azhar Mohamad Meerun
    Boris Guiu
    Jean-Paul Beregi
    Joël Greffier
    European Radiology Experimental, 7
  • [48] Low-Tube-Voltage, High-Tube-Current Multidetector Abdominal CT: Improved Image Quality and Decreased Radiation Dose with Adaptive Statistical Iterative Reconstruction Algorithm-Initial Clinical Experience
    Marin, Daniele
    Nelson, Rendon C.
    Schindera, Sebastian T.
    Richard, Samuel
    Youngblood, Richard S.
    Yoshizumi, Terry T.
    Samei, Ehsan
    RADIOLOGY, 2010, 254 (01) : 145 - 153
  • [49] The impact of deep learning reconstruction on image quality and coronary CT angiography-derived fractional flow reserve values
    Cheng Xu
    Min Xu
    Jing Yan
    Yan-Yu Li
    Yan Yi
    Yu-Bo Guo
    Ming Wang
    Yu-Mei Li
    Zheng-Yu Jin
    Yi-Ning Wang
    European Radiology, 2022, 32 : 7918 - 7926
  • [50] The impact of deep learning reconstruction on image quality and coronary CT angiography-derived fractional flow reserve values
    Xu, Cheng
    Xu, Min
    Yan, Jing
    Li, Yan-Yu
    Yi, Yan
    Guo, Yu-Bo
    Wang, Ming
    Li, Yu-Mei
    Jin, Zheng-Yu
    Wang, Yi-Ning
    EUROPEAN RADIOLOGY, 2022, 32 (11) : 7918 - 7926