Statistical analysis of the lightning performance of high voltage OHLs using dynamic simulation of lightning leaders movements

被引:8
|
作者
Tavakoli, M. R. Bank [1 ]
Vahidi, B. [1 ]
机构
[1] Amirkabir Univ Technol, Dept Elect Engn, Tehran, Iran
关键词
Charge simulation method; Lightning; Simulation; Overhead line; TRANSMISSION-LINE; SHIELDING FAILURE; POSITIVE-SPARK; ANALYSIS MODEL; EXPOSURE;
D O I
10.1016/j.ijepes.2010.02.002
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In this paper a simulation ground is designed to track the lightning path from cloud to the striking point on high voltage overhead line (OHL) structures. By using this simulation method, the strikes to towers, phase wires, ground wires and earth is counted. The method also reveals the property of strokes attaching the phase wires like their path, their peak current and their distance from earth in final jump. The simulation environment consists of two towers, ground wires, phase wires and earth comprising a full span. The downward lightning leader is simulated based on field observations by stepping line charges coming down. The inception of upward leader is tested in each step movement to find the target striking point. Using this method, lightning performance of an OHL is investigated and the number of strikes as well as highest lightning current attaching the phase wires is extracted. The results, yield by proposed method, are also compared with the existing methods of OHL lightning performance analysis. (C) 2010 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1024 / 1030
页数:7
相关论文
共 50 条
  • [41] Analysis of Transient Behavior of Mixed High Voltage DC Transmission Line Under Lightning Strikes
    Asif, Mansoor
    Lee, Ho-Yun
    Khan, Umer Amir
    Park, Kyu-Hoon
    Lee, Bang-Wook
    IEEE ACCESS, 2019, 7 : 7194 - 7205
  • [42] Analysis of Lightning Strike Failure of Extra High Voltage Overhead Lines in Hubei Power Grid
    Shi, Tianru
    Yang, Jianlan
    Lin, Xiaoqing
    Huang, Lei
    Wang, Guan
    2020 IEEE STUDENT CONFERENCE ON ELECTRIC MACHINES AND SYSTEMS (SCEMS 2020), 2020, : 306 - 311
  • [43] Line Lightning Protection Device Analysis for 70 kV High Voltage Overhead Line in Malang
    Cahya, Vanny Fitria
    Zoro, Reynaldo
    PROCEEDING OF 2019 INTERNATIONAL CONFERENCE ON ELECTRICAL ENGINEERING AND INFORMATICS (ICEEI), 2019, : 666 - 671
  • [44] THE LIGHTNING PERFORMANCE OF A SUBOPTIMAL DOUBLE-CIRCUIT TOWER FOR HIGH-VOLTAGE TRANSMISSION-LINES
    BOUQUEGNEAU, CR
    GREGOIRE, CA
    ELECTRIC POWER SYSTEMS RESEARCH, 1981, 4 (02) : 159 - 165
  • [45] Application of artificial neural network methods for the lightning performance evaluation of Hellenic high voltage transmission lines
    Ekonomou, L.
    Gonos, I. F.
    Iracleous, D. P.
    Stathopulos, I. A.
    ELECTRIC POWER SYSTEMS RESEARCH, 2007, 77 (01) : 55 - 63
  • [46] Protection against Lightning Electromagnetic Pulses Using Surge Arresters: A Simulation Study for the Realistic High-voltage Power Line Region
    Cakil, Turan
    Carlak, H. Feza
    Ozen, Sukru
    2021 PHOTONICS & ELECTROMAGNETICS RESEARCH SYMPOSIUM (PIERS 2021), 2021, : 2465 - 2473
  • [47] Equivalent Circuit of Distribution Line for Lightning-Induced Voltage Analysis Using Analytical Formulas
    Sekioka, Shozo
    ELECTRICAL ENGINEERING IN JAPAN, 2017, 199 (03) : 26 - 34
  • [48] Equivalent circuit of distribution line for lightning-induced voltage analysis using analytical formulas
    Sekioka S.
    Sekioka, Shozo (sekioka@elec.shonan-it.ac.jp), 1600, Institute of Electrical Engineers of Japan (136): : 610 - 616
  • [49] Lightning performance assessment of overhead high voltage transmission lines using an artificial neural network method and its application to the hellenic lines
    Ekonomou, L
    Iracleous, DP
    Gonos, IF
    Stathopulos, IA
    UPEC 2004: 39TH INTERNATIONAL UNIVERSITITIES POWER ENGINEERING CONFERENCE, VOLS 1-3, CONFERENCE PROCEEDINGS, 2005, : 363 - 367
  • [50] Analysis of Lightning-attractive Areas Around High-voltage Direct Current Transmission Line
    Nayel, Mohamed
    ELECTRIC POWER COMPONENTS AND SYSTEMS, 2009, 37 (02) : 146 - 157