HPLC and CE methods were employed to determine the quaternary benzo[c]phenanthridine alkaloid sanguinarine,in biological matrices (rat hepatocytes, human gingival fibroblasts, feed, porcine faeces, body fluids and tissues). HPLC was carried out on a C-18 column using gradient elution and ion pairing techniques with 1-heptanesulfonic acid as ion pairing agent under acidic conditions. The detection limit for fluorimetric detection at lambda(ex) = 327 nm and lambda(em) = 577 nm was 3 nM sanguinarine. CE analyses were performed in 50 mM phosphate-Na buffer pH 2.5, with 150 mM SDS used for pre-concentration by the sweeping effect. This experimental configuration allows injecting the total capillary length with sanguinarine sample. The detection limit for UV detection at 285 nm was 12 nM. Both methods are suitable for analysing submicromolar quantities of sanguinarine in biological materials. The HPLC method is more sensitive than CE because it uses fluorescence detection.
引用
收藏
页码:679 / 685
页数:7
相关论文
共 50 条
  • [31] Sample preparation for peptides and proteins in biological matrices prior to liquid chromatography and capillary zone electrophoresis
    Visser, N
    Lingeman, H
    Irth, H
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2005, 382 (03) : 535 - 558
  • [32] Sample preparation for peptides and proteins in biological matrices prior to liquid chromatography and capillary zone electrophoresis
    N. F. C. Visser
    H. Lingeman
    H. Irth
    Analytical and Bioanalytical Chemistry, 2005, 382 : 535 - 558
  • [33] Separation of stilbenes by capillary electrophoresis and high-performance liquid chromatography
    Wang, SP
    Huang, SP
    ELECTROPHORESIS, 2001, 22 (11) : 2222 - 2230
  • [34] Chiral resolution of flobufen by high performance liquid chromatography and capillary electrophoresis
    Tesarova, E
    Gilar, M
    Jegorov, A
    Uhrova, M
    Deyl, Z
    BIOMEDICAL CHROMATOGRAPHY, 1997, 11 (05) : 321 - 324
  • [35] Separation of anthraquinones by capillary electrophoresis and high-performance liquid chromatography
    Weng, Wu-Che
    Sheu, Shuenn-Jyi
    Journal of High Resolution Chromatography, 2000, 23 (02): : 143 - 148
  • [36] Application of calixarenes for high performance liquid chromatography, capillary electrophoresis and electrochromatography
    Li, LS
    Da, SL
    Feng, YQ
    Min, L
    PROGRESS IN CHEMISTRY, 2005, 17 (03) : 523 - 530
  • [37] Chiral Resolution of Flobufen by High Performance Liquid Chromatography and Capillary Electrophoresis
    Tesarova, E.
    Gilar, M.
    Jegorov, A.
    Uhrova, M.
    Biomedical Chromatography, 11 (05): : 321 - 324
  • [38] Separation of anthraquinones by capillary electrophoresis and high-performance liquid chromatography
    Weng, WC
    Sheu, SJ
    HRC-JOURNAL OF HIGH RESOLUTION CHROMATOGRAPHY, 2000, 23 (02): : 143 - 148
  • [39] Separation of nonionic surfactants by capillary electrophoresis and high performance liquid chromatography
    Heinig, K
    Vogt, C
    Werner, G
    ANALYTICAL CHEMISTRY, 1998, 70 (09) : 1885 - 1892
  • [40] Stability-indicating methods for the enantioselective determination of dihydropyridines by high performance liquid chromatography and capillary electrophoresis
    Galvao, Alyne Favero
    Ajimura, Tatiana Okura
    Aguiar, Fernando Armani
    Borges, Keyller Bastos
    de Gaitani, Cristiane Masetto
    ANALYTICAL METHODS, 2012, 4 (09) : 2953 - 2961