Sensitivity of equilibrium profile reconstruction to motional stark effect measurements

被引:11
|
作者
Batha, SH
Levinton, FM
Hirshman, SP
Bell, MG
Wieland, RM
机构
[1] OAK RIDGE NATL LAB,OAK RIDGE,TN
[2] PRINCETON UNIV,PRINCETON PLASMA PHYS LAB,PRINCETON,NJ 08543
关键词
D O I
10.1088/0029-5515/36/9/I03
中图分类号
O35 [流体力学]; O53 [等离子体物理学];
学科分类号
070204 ; 080103 ; 080704 ;
摘要
The magnetic-field pitch-angle profile, gamma(p)(R) = tan(-1)(B-pol/B-tor), is measured on TFTR using a motional Stark effect (MSE) polarimeter. Measured pitch angle profiles, along with kinetic profiles and external magnetic measurements, are used to compute a self-consistent equilibrium using the free-boundary variational moments equilibrium code VMEC. Uncertainties in the q profile due to uncertainties in gamma(p)(R), magnetic measurements and kinetic measurements are Found to be small. Subsequent uncertainties in the VMEC-calculated current density and shear profiles are also small.
引用
收藏
页码:1133 / 1143
页数:11
相关论文
共 50 条
  • [41] Measurements of the internal magnetic field using the B-Stark motional Stark effect diagnostic on DIII-D (inivited)
    Pablant, N. A.
    Burrell, K. H.
    Groebner, R. J.
    Holcomb, C. T.
    Kaplan, D. H.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2010, 81 (10):
  • [42] Improved signal analysis for motional Stark effect data
    Makowski, MA
    Allen, SL
    Ellis, R
    Geer, R
    Jayakumar, RJ
    Moller, JM
    Rice, BW
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2005, 76 (02): : 023706 - 1
  • [43] Effect of collisions on motional Stark broadening of spectral lines
    Rosato, J.
    JOURNAL OF QUANTITATIVE SPECTROSCOPY & RADIATIVE TRANSFER, 2023, 306
  • [44] Real-time motional Stark effect in jet
    Alves, D
    Stephen, A
    Hawkes, N
    Dalley, S
    Goodyear, A
    Felton, R
    Joffrin, E
    Fernandes, H
    FUSION ENGINEERING AND DESIGN, 2004, 71 (1-4) : 175 - 181
  • [45] Motional Stark effect diagnostic pilot experiment for MAST
    Kuldkepp, M.
    Walsh, M. J.
    Carolan, P. G.
    Conway, N. J.
    Hawkes, N. C.
    McCone, J.
    Rachlew, E.
    Wearing, G.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2006, 77 (10):
  • [46] Calibration of the upgraded motional Stark effect diagnostic on TFTR
    Levinton, FM
    Batha, SH
    Zarnstorff, MC
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1997, 68 (01): : 926 - 929
  • [47] Design of the Tore Supra motional Stark effect diagnostic
    Lotte, Ph.
    Echard, B.
    Hess, W.
    Migozzi, J.B.
    Rev. Sci. Instrum., 1600, 10
  • [48] Design of the Tore Supra motional Stark effect diagnostic
    Lotte, Ph.
    Echard, B.
    Hess, W.
    Migozzi, J. B.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2006, 77 (10):
  • [49] The motional Stark effect: Overview and future development (invited)
    Levinton, FM
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1999, 70 (01): : 810 - 814
  • [50] Motional Stark effect on bound-free spectra
    Gomez, Thomas A.
    Zammit, Mark C.
    Fontes, Christopher J.
    Bray, Igor
    White, Jackson
    PHYSICAL REVIEW A, 2024, 110 (03)