Design of a combined X-ray fluorescence Computed Tomography (CT) and photon-counting CT table-top imaging system

被引:7
|
作者
Dunning, C. A. S. [1 ]
Bazalova-Carter, M. [1 ]
机构
[1] Univ Victoria, Dept Phys & Astron, 3800 Finnerty Rd, Victoria, BC, Canada
基金
加拿大自然科学与工程研究理事会; 加拿大创新基金会;
关键词
X-ray fluorescence (XRF) systems; Computerized Tomography (CT) and Computed Radiography (CR); Multi-modality systems; CONTRAST AGENTS; XFCT; FEASIBILITY; SENSITIVITY; GADOLINIUM;
D O I
10.1088/1748-0221/15/06/P06031
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
This paper demonstrates the capability of a table-top x-ray imaging system to simultaneously image a small animal phantom loaded with Gd and Au contrast agents with photon-counting computed tomography (PCCT) and x-ray fluorescence CT (XFCT). Our table-top system consisted of a diagnostic x-ray tube, translation and rotation stages, a 330 tm-pitch cadmium zinc telluride (CZT) photon-counting detector with six energy bins, and two CdTe spectrometers which detected fluorescent x-rays in 0.5 keV bins. The energy bin thresholds on the CZT detector matched the contrast agent K-edge energies, enabling K-edge PCCT. A 3 cm-diameter phantom containing vials of 1% and 5% Gd and Au solutions by weight, including a mixed 1% Gd/Au vial, was scanned with 0.5 mm Cu-filtered 120 kVp x-rays at 2 mA. A pencil beam geometry was used with 33 translation and 30 rotation steps to form XFCT and K-edge PCCT images. A cone beam geometry with 180 rotation steps was used to form higher-resolution K-edge PCCT images. Three mice were each injected post-mortem with 0.2 mL of 5% Gd, Au, or mixed Gd/Au solutions in the upper torso and imaged similarly to the phantom. The lowest detectable concentration based on the Rose criterion for Gd and Au phantom data was 0.75% and 3.0% for XFCT, 0.81% and 0.82% for pencil beam K-edge PCCT, and 0.79% and 1.5% for cone beam K-edge PCCT. However, cone beam K-edge PCCT images have a much higher spatial resolution than the pencil beam images. The mixed 1% Gd/Au signal was diminished in the K-edge PCCT phantom images. Preliminary mouse images of Gd and Au among the imaging techniques were similar in image quality as the phantom images. This is the first demonstration of simultaneously-acquired XFCT and PCCT of both Gd and Au in a phantom on a table-top imaging system. On our system, cone beam PCCT is best for imaging Gd, pencil beam PCCT is best for imaging Au, and pencil beam XFCT is better suited toward resolving mixtures of contrast agents.
引用
收藏
页数:22
相关论文
共 50 条
  • [21] Material separation in x-ray CT with energy resolved photon-counting detectors
    Wang, Xiaolan
    Meier, Dirk
    Taguchi, Katsuyuki
    Wagenaar, Douglas J.
    Patt, Bradley E.
    Frey, Eric C.
    MEDICAL PHYSICS, 2011, 38 (03) : 1534 - 1546
  • [22] Material Separation in X-ray CT with Energy Resolved Photon-Counting Detectors
    Wang, X.
    Meier, D.
    Taguchi, K.
    Wagenaar, D. J.
    Patt, B. E.
    Frey, E. C.
    MEDICAL IMAGING 2011: PHYSICS OF MEDICAL IMAGING, 2011, 7961
  • [23] Photon Counting X-ray CT System with a Semiconductor Detector
    Kowase, Kazuhiko
    Ogawa, Koichi
    2006 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOL 1-6, 2006, : 3119 - 3123
  • [24] Simulation study on a photon counting X-ray CT system
    Ogawa, K
    Shibusawa, H
    Harata, Y
    Yamakawa, T
    2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, : 2755 - 2759
  • [25] Identification of a Material with a Photon Counting X-Ray CT System
    Ogawa, Koichi
    Hirokawa, Tatsuma
    Nakamura, Shota
    2010 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD (NSS/MIC), 2010, : 2582 - 2586
  • [26] Table-top soft x-ray imaging of nanometric films
    Calegari, F.
    Stagira, S.
    D'Andrea, C.
    Valentini, G.
    Vozzi, C.
    Nisoli, M.
    De Silvestri, S.
    Poletto, L.
    Villoresi, P.
    Faenov, A.
    Pikuz, T.
    APPLIED PHYSICS LETTERS, 2006, 89 (11)
  • [27] Photon Counting X-Ray Detectors and DR and CT Imaging Methods
    Taguchi, K.
    MEDICAL PHYSICS, 2008, 35 (06)
  • [28] A Hybrid Fluorescence Tomography and X-ray CT System for Quantitative Molecular Imaging
    Lin, Yuting
    Barber, William C.
    Iwanczk, Jan S.
    Roeck, Werner W.
    Nalcioglu, Orhan
    Gulsen, Gultekin
    MULTIMODAL BIOMEDICAL IMAGING V, 2010, 7557
  • [29] ON 2 METHODS OF TABLE-TOP X-RAY LASER DESIGN
    SHLYAPTSEV, VN
    GERUSOV, AV
    INSTITUTE OF PHYSICS CONFERENCE SERIES, 1992, (125): : 195 - 200
  • [30] Energy-Resolved Photon-Counting X-Ray Imaging Arrays for Clinical K-Edge CT
    Barber, William C.
    Nygard, Einar
    Wessel, Jan C.
    Malakhov, Nail
    Wawrzyniak, Gregor
    Hartsough, Neal E.
    Gandhi, Thulasi
    Iwanczyk, Jan S.
    2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 4441 - 4446