Monte Carlo Modeling of the Head of Varian Clinac 2100C Linear Accelerator Operating in 18 MV Utilizing GATE/GEANT4

被引:0
|
作者
Bezoubiri, Fethi [1 ]
Alem-Bezoubiri, Asma [1 ]
Khoudri, Saad [1 ,2 ]
Arib, Mehenna [3 ]
机构
[1] CRNA, Dept Phys Med, 02 Blvd Frantz Fanon,BP 399, Algiers 16000, RP, Algeria
[2] King Faisal Specialist Hosp & Res Cenfre, Ctr Reg Lutte Canc Blida, Serv Radiotherapie, Riyadh, Saudi Arabia
[3] King Faisal Specialist Hosp & Res Cenfre, Biomed Phys Dept, Riyadh, Saudi Arabia
关键词
D O I
10.1063/1.5048162
中图分类号
O59 [应用物理学];
学科分类号
摘要
In this study, the geometry of the head of VARIAN CLINAC 2100C linear accelerator lodged at Blida AntiCancer Centre in Algeria has been modeled using GATE/GEANT4 version 7.2. The model developed contains the majority of the components of the treatment head operating in 18 MV, such as: the target, the primary collimators, the flattening filter, the secondary collimators and the jaws. Using this model, associated with a water phantom of type RFA 200 with dimensions 63.8 cm x 40 cm x 44 cm positioned at a Source-to-Surface-Distance (SSD) of 100 cm, the interactions of the 18 MV radiations in water were simulated. The photon energy spectrum, the Percentage Depth Dose (PDD) and the beam quality specifiers such as D-10 (%), d(max) (cm), d(80)(cm), D-20/D-10 were calculated for field size of 10 cm x 10 cm utilizing the phase space technique. The results obtained in this study are in agreement with those obtained in our previous work using MCNP5 code.
引用
收藏
页数:4
相关论文
共 34 条
  • [1] Monte Carlo study of photoneutron production in the Varian Clinac 2100C linac
    A. Ma
    J. Awotwi-Pratt
    A. Alghamdi
    A. Alfuraih
    N. M. Spyrou
    Journal of Radioanalytical and Nuclear Chemistry, 2008, 276 : 119 - 123
  • [2] Monte Carlo study of photoneutron production in the Varian Clinac 2100C linac
    Ma, A.
    Awotwi-Pratt, J.
    Alghamdi, A.
    Alfuraih, A.
    Spyrou, N. M.
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2008, 276 (01) : 119 - 123
  • [3] Validation of Monte Carlo Geant4 code for a 6 MV Varian linac
    EL Bakkali, Jaafar
    EL Bardouni, Tarek
    JOURNAL OF KING SAUD UNIVERSITY SCIENCE, 2017, 29 (01) : 106 - 113
  • [4] Varian 2100C/D Clinac 18 MV photon phase space file characterization and modeling by using MCNP Code
    Ahad Ollah Ezzati
    The European Physical Journal Plus, 130
  • [5] Characterizing field sizes of the linear accelerator: Monte Carlo simulation in 6 MV SRS mode with GEANT4/GATE
    Khobbaizi, Youness
    Fathi, Ahmed
    Nabil, Sanaa
    Ardouz, Anas
    Sbiaai, Khalid
    APPLIED RADIATION AND ISOTOPES, 2025, 215
  • [6] Varian 2100C/D Clinac 18MV photon phase space file characterization and modeling by using MCNP Code
    Ezzati, Ahad Ollah
    EUROPEAN PHYSICAL JOURNAL PLUS, 2015, 130 (07):
  • [7] Monte Carlo Simulation of a 18 MV Medical Linac Photon Beam Using GATE/GEANT4
    M. Fiak
    A. Fathi
    J. Inchaouh
    A. Khouaja
    A. Benider
    M. Krim
    N. Harakat
    Z. Housni
    M. L. Bouhssa
    M. Mouadil
    Y. Elabssaoui
    O. Jdair
    Moscow University Physics Bulletin, 2021, 76 : 15 - 21
  • [8] Monte Carlo Simulation of a 18 MV Medical Linac Photon Beam Using GATE/GEANT4
    Fiak, M.
    Fathi, A.
    Inchaouh, J.
    Khouaja, A.
    Benider, A.
    Krim, M.
    Harakat, N.
    Housni, Z.
    Bouhssa, M. L.
    Mouadil, M.
    Elabssaoui, Y.
    Jdair, O.
    MOSCOW UNIVERSITY PHYSICS BULLETIN, 2021, 76 (01) : 15 - 21
  • [9] Development and commissioning of a Monte Carlo photon beam model for Varian Clinac 2100EX linear accelerator
    Mesbahi, A
    Reilly, AJ
    Thwaites, DI
    APPLIED RADIATION AND ISOTOPES, 2006, 64 (06) : 656 - 662
  • [10] Validation of Monte Carlo simulation of 6 MV photon beam produced by Varian Clinac 2100 linear accelerator using BEAMnrc code and DOSXYZnrc code
    Bencheikh M.
    Maghnouj A.
    Tajmouati J.
    Didi A.
    Ezzati A.O.
    Physics of Particles and Nuclei Letters, 2017, 14 (5) : 780 - 787