Comparison of measurement protocols to estimate preferred walking speed between sites

被引:13
|
作者
Johnson, Russell T. [1 ,2 ]
Hafer, Jocelyn F. [3 ,4 ]
Wedge, Ryan D. [1 ,5 ]
Boyer, Katherine A. [1 ,6 ]
机构
[1] Univ Massachusetts, Dept Kinesiol, 30 Eastman Lane, Amherst, MA 01003 USA
[2] Univ Southern Calif, Div Biokinesiol & Phys Therapy, 1540 W Alcassar St,CHP 155, Los Angeles, CA 90089 USA
[3] Univ Michigan, Sch Kinesiol, 401 Washtenaw Ave, Ann Arbor, MI 48109 USA
[4] Univ Delaware, Dept Kinesiol & Appl Physiol, 100 Discovery Blvd, Newark, DE 19713 USA
[5] East Carolina Univ, Dept Phys Therapy, 600 Moye Blvd, Greenville, NC 27834 USA
[6] Univ Massachusetts Med Sch, Dept Orthoped & Phys Rehabil, 55 N Lake Ave, Worcester, MA 01655 USA
关键词
Gait; Methodology; Walking velocity; Locomotion; Self-selected; SELF-SELECTED WALKING; GAIT SPEED;
D O I
10.1016/j.gaitpost.2020.01.007
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Background: Walking speed influences a variety of typical outcome measures in gait analysis. Many researchers use a participant's preferred walking speed (PWS) during gait analysis with a goal of trying to capture how a participant would typically walk. However, the best practices for estimating PWS and the impact of laboratory size and walk distance are still unclear. Research question: Is measured PWS consistent across different distances and between two laboratory sites? Methods: Participants walked overground at a "comfortable speed" for six different conditions with either dynamic (4, 6, 10, and 400 m) or static (4 and 10 m) starts and stops at two different data collection sites. Repeated measures ANOVA with Bonferroni corrections were used to test for differences between conditions and sites. Results: Participants walked significantly faster in the 4, 6, and 10 m dynamic conditions than in the 400 m condition. On average, participants walked slower in the static trials than the dynamic trials of the same distance. There was a significant interaction of lab and condition and so results were examined within each lab. Across both labs, we found that the 4 and 10 m dynamic conditions were not different than the 6 m dynamic condition at both sites, while other tests did not provide consistent results at both sites. Significance: We recommend researchers use a 6 m distance with acceleration and deceleration zones to reliably test for PWS across different laboratories. Given some of the differences found between conditions that varied by site, we also emphasize the need to report the test environment and methods used to estimate PWS in all future studies so that the methods can be replicated between studies.
引用
收藏
页码:171 / 174
页数:4
相关论文
共 50 条
  • [41] The effect of treadmill and overground walking on preferred walking speed and gait kinematics in healthy, physically active older adults
    Malatesta, Davide
    Canepa, Mose
    Fernandez, Aitor Menendez
    EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 2017, 117 (09) : 1833 - 1843
  • [42] The effect of treadmill and overground walking on preferred walking speed and gait kinematics in healthy, physically active older adults
    Davide Malatesta
    Mosè Canepa
    Aitor Menendez Fernandez
    European Journal of Applied Physiology, 2017, 117 : 1833 - 1843
  • [43] Accelerometer measurement differences between the preferred and non-preferred wrist
    Daniels, Bryce T.
    Gallagher, Kaitlin M.
    Gray, Michelle
    Howie, Erin K.
    HEALTH AND TECHNOLOGY, 2021, 11 (06) : 1259 - 1267
  • [44] COMPARISON OF DOSE MEASUREMENT PROTOCOLS IN MAMMOGRAPHY
    YOUNG, KC
    RADIATION PROTECTION DOSIMETRY, 1995, 57 (1-4) : 401 - 403
  • [45] Accelerometer measurement differences between the preferred and non-preferred wrist
    Bryce T. Daniels
    Kaitlin M. Gallagher
    Michelle Gray
    Erin K. Howie
    Health and Technology, 2021, 11 : 1259 - 1267
  • [46] Skinfold thickness measurement in athletes: a comparison between Lohman's and ISAK protocols
    Santos, Diana A.
    Matias, Catarina N.
    Sardinha, Luis B.
    Silva, Analiza M.
    EUROPEAN JOURNAL OF CLINICAL NUTRITION, 2015, 69 : S28 - S28
  • [47] Measurement and comparison of human and humanoid walking
    Kagami, S
    Mochimaru, M
    Ehara, Y
    Miyata, N
    Nishiwaki, K
    Kanade, T
    Inoue, H
    2003 IEEE INTERNATIONAL SYMPOSIUM ON COMPUTATIONAL INTELLIGENCE IN ROBOTICS AND AUTOMATION, VOLS I-III, PROCEEDINGS, 2003, : 918 - 922
  • [48] A Comparison of the Lower Limb Muscles Activities between Walking and Jogging Performed at the Same Speed
    Tsuji, Keiichi
    Soda, Naoki
    Okada, Naoyuki
    Ueki, Tsutomu
    Oba, Kaori
    Ikedo, Yasuyo
    Imaizumi, Hiroshi
    JOURNAL OF PHYSICAL THERAPY SCIENCE, 2012, 24 (01) : 23 - 26
  • [49] Preferred distances between transcription factor binding sites
    I. V. Kulakovskiy
    A. S. Kasianov
    A. A. Belostotsky
    I. A. Eliseeva
    V. J. Makeev
    Biophysics, 2011, 56 (1)
  • [50] Interaction between temozolomide and water: Preferred binding sites
    Kasende, Okuma E.
    Matondo, Aristote
    Muzomwe, Mayaliwa
    Muya, Jules Tshishimbi
    Schemer, Steve
    COMPUTATIONAL AND THEORETICAL CHEMISTRY, 2014, 1034 : 26 - 31