Purpose: Most studies have shown that the rate of inferior vena cava filter (IVCF) retrieval rarely exceeds 30%. A review of practices in our own institution revealed similar results (18%). Within the last year, few centers have demonstrated improved retrieval rates. Our hypothesis was that developing a dedicated program would improve IVCF retrieval. We report the results of an ongoing study following the development of this program. Methods: This is a cohort of nontrauma consecutive patients who had an IVCF placed by the vascular service over a 12-month period (January 2010-January 2011) and were followed prospectively. A dedicated nurse practitioner was responsible in developing a database, maintaining contact with all the patients, and ensuring that arrangements were made for retrieval when indications for IVCF protection were no longer present. Demographics, indication for filter placement, timing to filter retrieval, and complications during placement and retrieval were prospectively collected. Retrieval rate was compared to the baseline institution data. Results: During the study period, 42 patients had an DICE placed. There were 27 men and 15 women with a mean age of 58 (25 to 88 years old). Two patients were excluded (one due to mortality and one had multiple filters) leaving 40 patients in the study. Indications for IVCF placement were absolute in 23 of 40 patients (58%), relative in 10 of 40 patients (25%), while seven patients (17%) had an DICE placed for prophylaxis as they were considered high risk for pulmonary embolism (PE) and could not receive any chemical regimen. During follow-up, five filters were converted to permanent. Therefore, retrieval was successful in 19 of 22 patients with an 86% success rate and no complications. Median time to retrieval was 21 days ranging from 4 to 140 days. Retrieval rate for IVCFs designated as temporary at the time of placement was 70% (19 of 27), which was significantly higher compared to our baseline data of 18% (P < .001). Conclusion: Initial data show that a dedicated program that closely monitors patients with temporary IVCFs for ongoing need of filter prophylaxis can result in high retrieval rates. The endurance and long-term success of such a program needs to be further validated. (J Vase Surg 2011;54:34S-8S.)
引用
收藏
页码:34S / 38S
页数:5
相关论文
共 50 条
  • [31] Observations on failed retrieval of optional inferior vena cava filters
    Ballard, David H.
    Do, Daniel V.
    Laborde, Jeremy J.
    de Gregorio, Miguel A.
    Shi, Runhua
    D'Agostino, Horacio B.
    CLINICAL IMAGING, 2016, 40 (05) : 931 - 935
  • [32] Factors predicting failure of retrieval of inferior vena cava filters
    Morrow, Katherine L.
    Bena, James
    Lyden, Sean P.
    Parodi, Ezequiel
    Smolock, Christopher J.
    JOURNAL OF VASCULAR SURGERY-VENOUS AND LYMPHATIC DISORDERS, 2020, 8 (01) : 44 - 52
  • [33] Dual inferior vena cava: Two inferior vena cava filters
    Hashmi, Zubair A.
    Smaroff, Gregory G.
    ANNALS OF THORACIC SURGERY, 2007, 84 (02): : 661 - 663
  • [34] Complication and Retrieval Rates of Inferior Vena Cava Filters, a Single-Center Retrospective Study
    Parker, Nathaniel A.
    Mohla, Ankit
    Kujath, Scott W.
    Stark, Karl R.
    Wilson, Jonathon E.
    Thomas, Rebecca J.
    Carter, Robert R.
    JOURNAL OF VASCULAR SURGERY, 2016, 64 (03) : 868 - 869
  • [35] Vena cava filters and inferior vena cava thrombosis
    Corriere, Matthew A.
    Suave, Kenneth J.
    Ayerdi, Juan
    Craven, Brandon L.
    Stafford, Jeanette M.
    Geary, Randolph L.
    Edwards, Matthew S.
    JOURNAL OF VASCULAR SURGERY, 2007, 45 (04) : 789 - 794
  • [36] Inferior Vena Cava Filters
    Nicolaides, A.
    Fareed, J.
    Kakkar, A. K.
    Comerota, A. J.
    Goldhaber, S. Z.
    Hull, R.
    Myers, K.
    Samama, M.
    Fletcher, J.
    Kalodiki, E.
    Bergqvist, D.
    Bonnar, J.
    Caprini, J. A.
    Carter, C.
    Conard, J.
    Eklof, B.
    Elalamy, I.
    Gerotziafas, G.
    Geroulakos, G.
    Giannoukas, A.
    Greer, I.
    Griffin, M.
    Kakkos, S.
    Lassen, M. R.
    Lowe, G. D. O.
    Markel, A.
    Prandoni, P.
    Raskob, G.
    Spyropoulos, A. C.
    Turpie, A. G.
    Walenga, J. M.
    Warwick, D.
    CLINICAL AND APPLIED THROMBOSIS-HEMOSTASIS, 2013, 19 (02) : 204 - 205
  • [37] Inferior vena cava filters
    Kennedy, Sean A.
    Baerlocher, Mark O.
    CANADIAN MEDICAL ASSOCIATION JOURNAL, 2015, 187 (16) : 1234 - 1234
  • [38] Inferior vena cava filters
    Bergqvist, David
    WORLD JOURNAL OF SURGERY, 2007, 31 (02) : 265 - 266
  • [39] Inferior Vena Cava Filters
    David Bergqvist
    World Journal of Surgery, 2007, 31 : 265 - 266
  • [40] INFERIOR VENA CAVA FILTERS
    不详
    INTERNATIONAL ANGIOLOGY, 2013, 32 (02) : 223 - 224