Sentinel Lymphadenectomy in Vulvar Cancer Using Near-Infrared Fluorescence From Indocyanine Green Compared With Technetium 99m Nanocolloid

被引:30
|
作者
Soergel, Philipp [1 ]
Hertel, Hermann [1 ]
Nacke, Anna Kaarina [1 ]
Klapdor, Ruediger [1 ]
Derlin, Thorsten [2 ]
Hillemanns, Peter [1 ]
机构
[1] Hannover Med Sch, Dept Obstet & Gynaecol, Carl Neuberg Str 1, D-30625 Hannover, Germany
[2] Hannover Med Sch, Dept Nucl Med, Hannover, Germany
关键词
Tc-99m; Indocyanine green; Near-infrared detection; Sentinel lymph node; Vulvar cancer; LYMPH-NODE BIOPSY; GROINSS-V; FOLLOW-UP; DISSECTION; CARCINOMA; LOCALIZATION; MULTICENTER; SURVIVAL; GUIDANCE; TRACERS;
D O I
10.1097/IGC.0000000000000996
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Objective Nowadays, sentinel diagnostic is performed using technetium 99m (Tc-99m) nanocolloid as a radioactive marker and sometimes patent blue. In the last years, indocyanine green has been evaluated for sentinel diagnostic in different tumor entities. Indocyanine green is a fluorescent molecule that emits a light signal in the near-infrared band after excitation. Our study aimed to evaluate indocyanine green compared with the criterion-standard Tc-99m-nanocolloid. Methods We included patients with primary, unifocal vulvar cancer of less than 4 cm with clinically node-negative groins in this prospective trial. Sentinel diagnostic was carried out using Tc-99m-nanocolloid, indocyanine green, and patent blue. We examined each groin for light signals from the near-infrared band, for radioactivity, and for blue staining. A sentinel lymph node was defined as a Tc-99m-nanocolloid-positive lymph node. All sentinel lymph nodes and all additional blue or fluorescent lymph nodes were excised and tested and then sent for histologic examination. Results In all, 27 patients were included in whom we found 91 sentinel lymph nodes in 52 groins. All these lymph nodes were positive for indocyanine green, also giving a sensitivity of 100% (95% confidence interval [CI], 96.0%-100%) compared with Tc-99m-nanocolloid. Eight additional lymph nodes showed indocyanine green fluorescence but no Tc-99m positivity, so that the positive predictive value was 91.9% (95% confidence interval, 84.6%-96.5%). In 1 patient, a false-negative sentinel missed by all 3 modalities was found. Conclusions Our results show that indocyanine green is a promising approach for inguinal sentinel identification in vulvar cancer with a similar sensitivity as radioactive Tc-99m-nanocolloid and worth to be evaluated in further studies.
引用
收藏
页码:805 / 812
页数:8
相关论文
共 50 条
  • [31] Novel lymphography using indocyanine green dye for near-infrared fluorescence labeling
    Ogata, Fusa
    Azuma, Ryuichi
    Kikuchi, Makoto
    Koshima, Isao
    Morimoto, Yuji
    ANNALS OF PLASTIC SURGERY, 2007, 58 (06) : 652 - 655
  • [32] Evaluation of the Angiosome Concept Using Near-Infrared Fluorescence Imaging with Indocyanine Green
    Tange, Floris P.
    Ferrari, Bien R.
    van den Hoven, Pim
    van Schaik, Jan
    Schepers, Abbey
    van Rijswijk, Catharina S. P.
    van der Meer, Rutger W.
    Putter, Hein
    Vahrmeijer, Alexander L.
    Hamming, Jaap F.
    van der Vorst, Joost R.
    ANNALS OF VASCULAR SURGERY, 2023, 93 : 283 - 290
  • [33] Near-Infrared Fluorescence Imaging of Liver Metastases in Rats using Indocyanine Green
    van der Vorst, Joost R.
    Hutteman, Merlijn
    Mieog, J. Sven D.
    de Rooij, Karien E.
    Kaijzel, Eric L.
    Lowik, Clemens W. G. M.
    Putter, Hein
    Kuppen, Peter J. K.
    Frangioni, John V.
    van de Velde, Cornelis J. H.
    Vahrmeijer, Alexander L.
    JOURNAL OF SURGICAL RESEARCH, 2012, 174 (02) : 266 - 271
  • [34] Intraoperative Fluorescence Imaging for Sentinel Lymph Node Detection Prospective Clinical Trial to Compare the Usefulness of Indocyanine Green vs Technetium Tc 99m for Identification of Sentinel Lymph Nodes
    Stoffels, Ingo
    Dissemond, Joachim
    Poeppel, Thorsten
    Schadendorf, Dirk
    Klode, Joachim
    JAMA SURGERY, 2015, 150 (07) : 617 - 623
  • [35] Sentinel lymph node mapping in patients with vulvar malignancies using indocyanine green and near-infrared imaging: Preliminary detection rate experience
    Leitao, M. M.
    Jewell, E.
    Gardner, G. J.
    Zivanovic, O.
    Levine, D. A.
    Barakat, R. R.
    Abu-Rustum, N. R.
    GYNECOLOGIC ONCOLOGY, 2015, 137 : 100 - 100
  • [36] Performance of Indocyanine Green Compared to 99mTc-Nanocolloids for Sentinel Lymph Node Detection in Early Vulvar Cancer
    Benmoulay-Rigollot, Camelia
    Karpathiou, Georgia
    Prevot-Bitot, Nathalie
    Heinemann, Mellie
    Trombert-Paviot, Beatrice
    Barjat, Tiphaine
    Chauleur, Celine
    CURRENT ONCOLOGY, 2022, 29 (11) : 8084 - 8092
  • [37] Sentinel lymph node biopsy for breast cancer using a new camera system for simultaneous capturing color and near-infrared fluorescence of indocyanine green
    Sugimoto, T.
    Sato, T.
    Ogata, H.
    Funakoshi, T.
    Hanazaki, K.
    EJC SUPPLEMENTS, 2008, 6 (07): : 148 - 149
  • [38] Comparison between periareolar and peritumoral injection techniques with only 99m technetium-nanocolloid for sentinel lymph node detection in breast cancer
    Vaggelli, L
    Orzalesi, L
    Distante, V
    Matteini, M
    Vezzosi, V
    Castagnoli, A
    Cataliotti, L
    Briganti, V
    Pieroni, C
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2004, 31 : S450 - S451
  • [39] Investigation of optimizing indocyanine green solution for in vivo lymphatic research using near-infrared fluorescence indocyanine green lymphangiography
    Hwayeong Cheon
    Sang Ah Kim
    Bumchul Kim
    Jae Yong Jeon
    Scientific Reports, 13
  • [40] Investigation of optimizing indocyanine green solution for in vivo lymphatic research using near-infrared fluorescence indocyanine green lymphangiography
    Cheon, Hwayeong
    Kim, Sang Ah
    Kim, Bumchul
    Jeon, Jae Yong
    SCIENTIFIC REPORTS, 2023, 13 (01)