Evaluating the temporomandibular joint disc using calcium-suppressed technique in dual-layer detector computed tomography

被引:1
|
作者
Zhang, Xiaohuan [1 ]
Liu, Mengqi [1 ,2 ]
Wang, Yanyi [3 ]
Deng, Weiwei [4 ]
Tan, Houmin [4 ]
Fan, Wenping [1 ]
Chen, Zhiye [1 ,2 ]
机构
[1] Chinese Peoples Liberat Army Gen Hosp, Dept Radiol, Hainan Hosp, Sanya 572013, Hainan, Peoples R China
[2] Chinese Peoples Liberat Army Gen Hosp, Med Ctr 1, Dept Radiol, Beijing, Peoples R China
[3] Chinese Peoples Liberat Army Gen Hosp, Hainan Hosp, Dept Stomatol, Sanya, Hainan, Peoples R China
[4] Philips Healthcare China, Shanghai, Peoples R China
关键词
Temporomandibular disorders; temporomandibular joint; dual-layer detector CT; spectral detector CT; magnetic resonance imaging; calcium-suppressed technique; BONE-MARROW EDEMA; ENERGY CT; QUANTITATIVE PARAMETERS; PREOPERATIVE DIAGNOSIS; FRACTURES; CANCER; ACCURACY;
D O I
10.1177/0300060519891332
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Objectives To investigate the application value of the calcium-suppressed (CaSupp) images of dual-layer detector computed tomography (DLCT) in the evaluation of the temporomandibular joint (TMJ) discs. Methods Thirty-three healthy subjects underwent DLCT and magnetic resonance imaging (MRI) examinations. CaSupp images were reconstructed from the spectral-based images using a calcium suppression algorithm. The location, morphology, and thickness of the posterior band of the TMJ discs were evaluated on the oblique sagittal proton-density weighted images and CaSupp images. Results Of the 66 TMJ discs, anterior displacement was observed on 9 TMJ discs on MR images and 6 TMJ discs on CaSupp images, and posterior displacement was present on 3 TMJ discs on MR and CaSupp images. No significant difference was observed in TMJ disc displacement between MR images and CaSupp images (P value = 0.730). The TMJ discs without displacement had no significant difference in the thickness of the posterior band between the MR and CaSupp images (P value = 0.401). Conclusions The calcium-suppressed technique in DLCT may be a simple and preliminary way to evaluate the TMJ disc displacement and structure.
引用
收藏
页数:10
相关论文
共 50 条
  • [41] Dual-Layer Spectral Detector Computed Tomography Quantitative Parameters: A Potential Tool for Lymph Node Activity Determination in Lymphoma Patients
    Chen, Hebing
    Fang, Yuxiang
    Gu, Jin
    Sun, Peng
    Yang, Lian
    Pan, Feng
    Wu, Hongying
    Ye, Tianhe
    DIAGNOSTICS, 2024, 14 (02)
  • [42] Added value of spectral parameters for the assessment of lymph node metastasis of lung cancer with dual-layer spectral detector computed tomography
    Gao, Lu
    Lu, Xiaomei
    Wen, Qingyun
    Hou, Yang
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2021, 11 (06) : 2622 - 2633
  • [43] Quantitative parameters of dual-layer spectral detector computed tomography for evaluating Ki-67 and human epidermal growth factor receptor 2 expression in colorectal adenocarcinoma
    Chen, Jinghua
    Tang, Liang
    Xie, Ping
    Qian, Tingting
    Huang, Jian
    Liu, Kefu
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2024, 14 (01) : 789 - 799
  • [44] Improved detectability of hypoattenuating focal pancreatic lesions by dual-layer computed tomography using virtual monoenergetic images
    Nada El Kayal
    Ahmed Mohallel
    David Maintz
    Mohamed Eid
    Doaa Mokhtar Emara
    Egyptian Journal of Radiology and Nuclear Medicine, 51
  • [45] Accuracy of Quantification of Iodine and Hounsfield Unit Values on Virtual Monochromatic Imaging Using Dual-Energy Computed Tomography: Comparison of Dual-Layer Computed Tomography With Fast Kilovolt-Switching Computed Tomography
    Washio, Hayate
    Ohira, Shingo
    Karino, Tsukasa
    Nitta, Yuya
    Hayashi, Masaaki
    Miyazaki, Masayoshi
    Teshima, Teruki
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2018, 42 (06) : 965 - 971
  • [46] Late iodine enhancement and myocardial extracellular volume quantification in cardiac amyloidosis by using dual-energy cardiac computed tomography performed on a dual-layer spectral detector scanner
    Oda, Seitaro
    Nakaura, Takeshi
    Utsunomiya, Daisuke
    Hirakawa, Kyoko
    Takashio, Seiji
    Izumiya, Yasuhiro
    Tsujita, Kenichi
    Hata, Hiroyuki
    Ando, Yukio
    Yamashita, Yasuyuki
    AMYLOID-JOURNAL OF PROTEIN FOLDING DISORDERS, 2018, 25 (02): : 137 - 138
  • [47] Improved detectability of hypoattenuating focal pancreatic lesions by dual-layer computed tomography using virtual monoenergetic images
    El Kayal, Nada
    Mohallel, Ahmed
    Maintz, David
    Eid, Mohamed
    Emara, Doaa Mokhtar
    EGYPTIAN JOURNAL OF RADIOLOGY AND NUCLEAR MEDICINE, 2020, 51 (01):
  • [48] Non-Invasive Imaging in Pulmonary Hypertension - Comprehensive Assessment Using Dual-Layer Spectral Computed Tomography -
    Oda, Seitaro
    Kidoh, Masafumi
    Nagayama, Yasunori
    Nakaura, Takeshi
    Hirakawa, Kyoko
    Yamamoto, Eiichiro
    Tsujita, Kenichi
    Hirai, Toshinori
    CIRCULATION JOURNAL, 2021, 85 (03) : 316 - +
  • [49] Value of dual-layer spectral detector computed tomography in the diagnosis of benign/malignant solid solitary pulmonary nodules and establishment of a prediction model
    Xie, Xiaodong
    Liu, Kaifang
    Luo, Kai
    Xu, Youtao
    Zhang, Lei
    Wang, Meiqin
    Shen, Wenrong
    Zhou, Zhengyang
    FRONTIERS IN ONCOLOGY, 2023, 13
  • [50] Dual-layer detector spectral computed tomography quantitative parameters for predicting pathological complete remission after neoadjuvant treatment of breast cancer
    Guo, Shaolan
    Wang, Dandan
    Zhao, Qian
    Bi, Zhao
    Li, Wanhu
    Zhu, Jian
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2025, 15 (01) : 149 - 163