Digital enhancement of radiographs for assessment of interproximal dental caries

被引:13
|
作者
Seneadza, V. [1 ]
Koob, A. [1 ]
Kaltschmitt, J. [2 ]
Staehle, H. J. [2 ]
Duwenhoegger, J.
Eickholz, P. [3 ]
机构
[1] Univ Heidelberg Hosp, Clin Oral Dent & Maxillofacial Dis, Dept Conservat Dent, Dept Prosthodont, Heidelberg, Germany
[2] Univ Heidelberg Hosp, Clin Oral Dent & Maxillofacial Dis, Dept Conservat Dent, Sect Periodont, Heidelberg, Germany
[3] Hosp Johann Wolfgang Goethe Univ, Ctr Dent Oral & Maxillofacial, Dept Periodontol, D-6000 Frankfurt, Germany
关键词
dental caries; radiology; diagnostic X-ray; radiographic image enhancement; validity;
D O I
10.1259/dmfr/51572889
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: Evaluation of a particular digital caries image-enhancing mode (filter) for its effect on the validity of measurements of caries lesion depth. Methods: Standardized radiographs of 44 extracted teeth exhibiting interproximal caries lesions were obtained. Six radiographs were obtained of each tooth and digitized. Four radiographs were made using D-speed film with and without soft tissue scattering equivalent (STSE) at normal exposure time (0.32 s) and underexposed (0.16 s). Two were made using E-speed film with STSE normally (0.16 s) and underexposed (0.08 s). On each of the 264 radiographs, 4 independent examiners measured the central depth (CD) of 1 carious lesion per tooth both on the unchanged radiographic image and after use of the filter. Histometric CD assessments provided a gold standard for comparison with the radiographic measurements (validity). Repeated measures ANOVA was calculated for validity in relation to examiner, lesion type, filter, film type, exposure time and STSE. Results: The lesion type was identified to statistically significantly influence the validity of CD measurements. Examiner in combination with defect type (P < 0.001), filter (P = 0.017), exposure (P = 0.027) and film type (P = 0.044) had an additional albeit small effect. Conclusions: The lesion type significantly influenced the validity of CD measurements: enamel lesions were less underestimated than dentin lesions.
引用
收藏
页码:142 / 148
页数:7
相关论文
共 50 条
  • [41] Diagnostic accuracy of two software modalities for detection of caries lesions in digital radiographs from four dental systems
    Hintze, H
    DENTOMAXILLOFACIAL RADIOLOGY, 2006, 35 (02) : 78 - 82
  • [42] A comparison of diagnosis of early stage interproximal caries with bitewing radiographs and periapical images using consensus reference
    Takahashi, Noriaki
    Lee, Cliff
    Da Silva, John Daren
    Ohyama, Hiroe
    Roppongi, Motoi
    Kihara, Hidemichi
    Hatakeyama, Vataru
    Ishikawa-Nagai, Shigemi
    Izumisawa, Mitsuru
    DENTOMAXILLOFACIAL RADIOLOGY, 2019, 48 (02)
  • [43] Interproximal dental caries detection using photothermal radiometry (PTR) and modulated luminescence (LUM)
    Jeon, R. J.
    Matvienko, A.
    Mandelis, A.
    Abrams, S. H.
    Amaechi, B. T.
    Kulkarni, G.
    EUROPEAN PHYSICAL JOURNAL-SPECIAL TOPICS, 2008, 153 (1): : 467 - 469
  • [44] Advanced AI-driven detection of interproximal caries in bitewing radiographs using YOLOv8
    Bayati, Mahsa
    Savareh, Berhrouz Alizadeh
    Ahmadinejad, Hojjat
    Mosavat, Farzaneh
    SCIENTIFIC REPORTS, 2025, 15 (01):
  • [45] CRITERIA FOR ASSESSMENT OF INTERPROXIMAL BONE LOSS ON BITE-WING RADIOGRAPHS IN ADOLESCENTS
    KALLESTAL, C
    MATSSON, L
    JOURNAL OF CLINICAL PERIODONTOLOGY, 1989, 16 (05) : 300 - 304
  • [46] Interproximal dental caries detection using Photothermal Radiometry (PTR) and Modulated Luminescence (LUM)
    R. J. Jeon
    A. Matvienko
    A. Mandelis
    S. H. Abrams
    B. T. Amaechi
    G. Kulkarni
    The European Physical Journal Special Topics, 2008, 153 : 467 - 469
  • [47] Digital radiographs - Imaging technology for the dental office
    不详
    JOURNAL OF THE AMERICAN DENTAL ASSOCIATION, 2006, 137 (11): : 1624 - 1624
  • [48] Children’s dental panoramic radiographs dataset for caries segmentation and dental disease detection
    Yifan Zhang
    Fan Ye
    Lingxiao Chen
    Feng Xu
    Xiaodiao Chen
    Hongkun Wu
    Mingguo Cao
    Yunxiang Li
    Yaqi Wang
    Xingru Huang
    Scientific Data, 10
  • [49] Assessment of common errors and subjective quality of digital panoramic radiographs in dental institution, Riyadh
    Lingam, Amara Swapna
    Koppolu, Pradeep
    Abdulsalam, Rasheed
    Reddy, Reddy
    Anwarullah, Anupreeta
    Koppolu, Deepak
    ANNALS OF AFRICAN MEDICINE, 2023, 22 (01) : 49 - 54
  • [50] Interproximal caries depth determination: Comparing two conventional intraoral dental films.
    Jessee, S
    Makins, S
    JOURNAL OF DENTAL RESEARCH, 1997, 76 : 1980 - 1980