Accuracy of real-time optoacoustic temperature determination during retinal photocoagulation

被引:4
|
作者
Baade, A. [1 ]
Schlott, K. [1 ]
Luft, S. [2 ]
Ptaszynski, L. [1 ]
Bever, M. [1 ]
Birngruber, R. [1 ,2 ]
Brinkmann, R. [1 ,2 ]
机构
[1] Med Laserzentrum Lubeck GmbH, Peter Monnik Weg 4, D-23562 Lubeck, Germany
[2] Inst Biomedizinische Optik, D-23562 Lubeck, Germany
关键词
optoacoustics; ophthalmology; retina; photocoagulation; temperature;
D O I
10.1117/12.889608
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Retinal photocoagulation is an established treatment for various retinal diseases. The temperature development during a treatment can be monitored by applying short laser pulses in addition to the treatment laser light. The laser pulses induce optoacoustic pressure waves that can be detected at the cornea. Aim of this work is the investigation of the accuracy of the determined temperatures during a treatment. To calibrate the temperature dependency of the measured pressure, whole enucleated porcine eyes were heated using an infrared laser beam, while probing the retina optoacoustically. The temperatures and the optoacoustic pressure waves were measured simultaneously using thermocouples and a piezoelectric element, respectively. From the deviation of the individual measurements an error of less than 15% in the calibration regime between 37 degrees C to 55 degrees C was found. Furthermore, the spatial and temporal temperature course was investigated. Calculations were performed to simulate the temporal and spatial temperature development during photocoagulation. A theoretical model to determine the peak temperature of the irradiated tissue from the mean temperature measured by optoacoustics was developed. The validity of the model was experimentally examined by heating the retina of porcine eyes with a laser beam diameter of 500 mu m while successively measuring the temperature optoacoustically with a probe beam diameter of 500 mu m and 100 mu m at the center of the heated area, respectively. The deviation of the theoretical model and the experimental results were found to be less than 7%.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Real-time temperature determination during retinal photocoagulation on patients
    Brinkmann, Ralf
    Koinzer, Stefan
    Schlott, Kerstin
    Ptaszynski, Lars
    Bever, Marco
    Baade, Alexander
    Luft, Susanne
    Miura, Yoko
    Roider, Johann
    Birngruber, Reginald
    JOURNAL OF BIOMEDICAL OPTICS, 2012, 17 (06)
  • [2] Optoacoustic online temperature determination during retinal laser photocoagulation
    Schlott, Kerstin
    Stalljohann, Jens
    Weber, Benjamin
    Kandulla, Jochen
    Herrmann, Katharina
    Birngruber, Reginald
    Bninkmann, Ralf
    THERAPEUTIC LASER APPLICATIONS AND LASER-TISSUE INTERACTION III, 2007, 6632
  • [3] Consolidated numerical temperature/pressure modelling to assess the accuracy of optoacoustic temperature determination during retinal photocoagulation
    Baade, Alexander
    Schlott, Kerstin
    Birngruber, Reginald
    Brinkmann, Ralf
    OPTICAL INTERACTIONS WITH TISSUE AND CELLS XXV; AND TERAHERTZ FOR BIOMEDICAL APPLICATIONS, 2014, 8941
  • [4] Real-time optoacoustic temperature determination on cell cultures during heat exposure: a feasibility study
    Miura, Yoko
    Seifert, Eric
    Rehra, Josua
    Kern, Katharina
    Theisen-Kunde, Dirk
    Denton, Michael
    Brinkmann, Ralf
    INTERNATIONAL JOURNAL OF HYPERTHERMIA, 2019, 36 (01) : 466 - 472
  • [5] Non-invasive real-time retinal temperature determination during TTT
    Brinkmann, R
    Kandulla, J
    Elsner, H
    Hilmes, M
    Hartert, C
    Birngruber, R
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2005, 46
  • [6] Real-time optoacoustic monitoring of the temperature of the retina during laser therapy
    Serebryakov, V. A.
    Boiko, E. V.
    Yan, A. V.
    JOURNAL OF OPTICAL TECHNOLOGY, 2014, 81 (06) : 312 - 321
  • [7] Real-time optoacoustic monitoring of temperature in tissues
    Larina, IV
    Larin, KV
    Esenaliev, RO
    JOURNAL OF PHYSICS D-APPLIED PHYSICS, 2005, 38 (15) : 2633 - 2639
  • [8] Real-time optoacoustic monitoring of temperature in tissues
    Esenaliev, RO
    Oraevsky, AA
    Larin, KV
    Larina, IV
    Motamedi, M
    LASER-TISSUE INTERACTION X: PHOTOCHEMICAL, PHOTOTHERMAL, AND PHOTOMECHANICAL, PROCEEDINGS OF, 1999, 3601 : 268 - 275
  • [9] Real-time optoacoustic monitoring during thermotherapy
    Esenaliev, R
    Larina, I
    Larin, K
    Motamedi, M
    BIOMEDICAL OPTOACOUSTICS, 2000, 3916 : 302 - 310
  • [10] Realtime Temperature Determination during Retinal Photocoagulation on Patients
    Brinkmann, Ralf
    Koinzer, Stefan
    Schlott, Kerstin
    Ptaszynski, Lars
    Bever, Marco
    Baade, Alex
    Luft, Susanne
    Miura, Yoko
    Birngruber, Reginald
    Roider, Johann
    OPHTHALMIC TECHNOLOGIES XXI, 2011, 7885