Development of a multi-channel signal optimizer for a Compton camera system

被引:5
|
作者
Lee, J. H. [1 ]
Lee, C. S. [1 ]
机构
[1] Chung Ang Univ, Dept Phys, Seoul 156756, South Korea
关键词
signal optimizer; double-sided silicon strip detector; signal-to-noise ratio; Compton camera;
D O I
10.3938/jkps.52.999
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
A multi-channel differential-to-single-ended signal optimizer has been developed for application in a low-energy Compton camera system. The developed multi-channel signal optimizer enhanced the signal-to-noise ratio of the whole system compared to the case in which a simple resistive network converter was used. In order to verify the performance of the developed signal optimizer, we performed an energy measurement for gamma rays emitted from Am-241, Ba-133 and Cs-137 standard sources by using a double-sided silicon strip detector. The energy resolution of 19 keV, full width at half maximum, was obtained by fitting a 59.6-keV gamma-ray peak, and the energy threshold level of time pick-up circuits was determined to be 35 keV by comparing the measured energy spectrum with a simulated one obtained with a Monte Carlo code. The obtained energy resolution and the energy threshold level show that the developed signal optimizer can effectively enhance the signal-to-noise ratio for multi-channel electronics and enables us to construct a Compton camera system combined with low-cost commercially-available multi-channel electronics.
引用
收藏
页码:999 / 1003
页数:5
相关论文
共 50 条
  • [31] A Multi-channel ASIC for the Readout of the HICAM Gamma Camera
    Gola, A.
    Bombelli, L.
    Fiorini, C.
    Frizzi, T.
    Membretti, G.
    Nava, R.
    Peloso, R.
    2008 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (2008 NSS/MIC), VOLS 1-9, 2009, : 1085 - 1089
  • [32] Radiation calibration research on multi-channel CCD camera
    Liu, JG
    Li, J
    Hao, ZH
    Advanced Materials and Devices for Sensing and Imaging II, 2005, 5633 : 549 - 555
  • [33] Design and Development of a novel Multi-channel Photoplethysmographic Research System
    Rybynok, V.
    May, J. M.
    Budidha, K.
    Kyriacou, P. A.
    2013 IEEE POINT-OF-CARE HEALTHCARE TECHNOLOGIES (PHT), 2013, : 267 - 270
  • [34] Development and Realization of a Multi-Channel Synchronous Temperature Measurement System
    Fu Y.
    Meng X.
    Wu J.
    Hsi-An Chiao Tung Ta Hsueh/Journal of Xi'an Jiaotong University, 2017, 51 (03): : 62 - 67
  • [35] Development of multi-channel eddy current testing system in India
    Godbole, U
    INSIGHT, 2003, 45 (01) : 43 - 46
  • [36] Development of a Multi-Channel Array Resistivity Method Instrument System
    Zeng, Weihua
    Zhang, Jingjing
    Tan, Handong
    Hou, Shengli
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2022, 71
  • [37] Development of a multi-channel optical system for differential cortical measurement
    Maki, A
    Yamashita, Y
    Watanabe, E
    Koizumi, H
    OPTICAL TOMOGRAPHY AND SPECTROSCOPY OF TISSUE: THEORY, INSTRUMENTATION, MODEL, AND HUMAN STUDIES II, PROCEEDINGS OF, 1997, 2979 : 704 - 709
  • [38] DEVELOPMENT OF A MULTI-CHANNEL TELEMETRY SYSTEM WITH 256 DATA CHANNELS
    AKATSU, T
    KINOSHITA, K
    TERASHIMA, S
    WATANABE, T
    IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1982, 101 (12): : 4527 - 4535
  • [39] Development of a Heuristics Model for Simplifying a Multi-Channel Queuing System
    Kareem, B.
    Aderoba, A. A.
    ADVANCES IN MATERIALS AND SYSTEMS TECHNOLOGIES III, 2012, 367 : 647 - 652
  • [40] Multi-channel Signal Generator Based on FPGA
    Zheng, Yan
    ELECTRONIC INFORMATION AND ELECTRICAL ENGINEERING, 2012, 19 : 508 - 510