A comparison of two antimicrobial-impregnated central venous catheters

被引:529
|
作者
Darouiche, RO
Raad, II
Heard, SO
Thornby, JI
Wenker, OC
Gabrielli, A
Berg, J
Khardori, N
Hanna, H
Hachem, R
Harris, RL
Mayhall, G
机构
[1] Vet Affairs Med Ctr, Infect Dis Sect, Houston, TX 77030 USA
[2] Baylor Coll Med, Dept Med, Houston, TX 77030 USA
[3] Baylor Coll Med, Dept Phys Med & Rehabil, Houston, TX 77030 USA
[4] Baylor Coll Med, Dept Family & Community Med, Houston, TX 77030 USA
[5] Baylor Coll Med, Dept Anesthesiol, Houston, TX 77030 USA
[6] Univ Texas, MD Anderson Canc Ctr, Dept Med Subspecialties, Houston, TX USA
[7] Univ Massachusetts, Med Ctr, Dept Anesthesiol, Worcester, MA USA
[8] Univ Florida, Coll Med, Dept Surg, Gainesville, FL USA
[9] Univ Florida, Coll Med, Dept Med, Gainesville, FL USA
[10] So Illinois Univ, Sch Med, Dept Med, Springfield, IL 62708 USA
[11] Univ Texas, Med Branch, Dept Med, Galveston, TX 77550 USA
来源
NEW ENGLAND JOURNAL OF MEDICINE | 1999年 / 340卷 / 01期
关键词
D O I
10.1056/NEJM199901073400101
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background The use of central venous catheters impregnated with either minocycline and rifampin or chlorhexidine and silver sulfadiazine reduces the rates of catheter colonization and catheter-related bloodstream infection as compared with the use of unimpregnated catheters. We compared the rates of catheter colonization and catheter-related bloodstream infection associated with these two kinds of antiinfective catheters. Methods We conducted a prospective, randomized clinical trial in 12 university-affiliate hospitals. High-risk adult patients in whom central venous catheters were expected to remain in place for three or more days were randomly assigned to undergo insertion of polyurethane, triple-lumen catheters impregnated with either minocycline and rifampin ton both the luminal and external surfaces) or chlorhexidine and silver sulfadiazine ton only the external surface). After their removal, the tips and subcutaneous segments of the catheters were cultured by both the roll-plate and the sonication methods. Peripheral-blood cultures were obtained if clinically indicated. Results Of 865 catheters inserted, 738 (85 percent) produced culture results that could be evaluated. The clinical characteristics of the patients and the risk factors for infection were similar in the two groups. Catheters impregnated with minocycline and rifampin were 1/3 as likely to be colonized as catheters impregnated with chlorhexidine and silver sulfadiazine (28 of 356 catheters [7.9 percent] vs. 87 of 382 [22.8 percent], P<0.001), and catheter-related bloodstream infection was 1/12 as likely in catheters impregnated with minocycline and rifampin (1 of 356 [0.3 percent], vs. 13 of 382 [3.4 percent] for those impregnated with chlorhexidine and silver sulfadiazine; P<0.002). Conclusions The use of central venous catheters impregnated with minocycline and rifampin is associated with a lower rate of infection than the use of catheters impregnated with chlorhexidine and silver sulfadiazine. (N Engl J Med 1999;340:1-8.) (C) 1999, Massachusetts Medical Society.
引用
收藏
页码:1 / 8
页数:8
相关论文
共 50 条
  • [31] Antimicrobial-impregnated and -coated shunt catheters for prevention of infections in patients with hydrocephalus: a systematic review and meta-analysis
    Konstantelias, Athanasios A.
    Vardakas, Konstantinos Z.
    Polyzos, Konstantinos A.
    Tansarli, Giannoula S.
    Falagas, Matthew E.
    JOURNAL OF NEUROSURGERY, 2015, 122 (05) : 1096 - 1112
  • [32] The ex vivo antimicrobial activity and colonization rate of two antimicrobial-bonded central venous catheters
    Marik, PE
    Abraham, G
    Careau, P
    Varon, J
    Fromm, RE
    CRITICAL CARE MEDICINE, 1999, 27 (06) : 1128 - 1131
  • [33] Clinical review: Efficacy of antimicrobial-impregnated catheters in external ventricular drainage - a systematic review and meta-analysis
    Wang, Xiang
    Dong, Yan
    Qi, Xiang-Qian
    Li, Yi-Ming
    Huang, Cheng-Guang
    Hou, Li-Jun
    CRITICAL CARE, 2013, 17 (04)
  • [34] Clinical review: Efficacy of antimicrobial-impregnated catheters in external ventricular drainage - a systematic review and meta-analysis
    Xiang Wang
    Yan Dong
    Xiang-Qian Qi
    Yi-Ming Li
    Cheng-Guang Huang
    Li-Jun Hou
    Critical Care, 17
  • [35] A comparative study between conventional and antiseptic impregnated central venous catheters
    SK Macedo
    JLFM Filho
    GCD Lima
    LBSA Brito
    Critical Care, 13 (Suppl 3):
  • [36] Comparative study between conventional and antiseptic impregnated central venous catheters
    S Macedo
    J Molina Filho
    G Lima
    L Brito
    Critical Care, 13 (Suppl 1):
  • [37] Activity of antibacterial impregnated central venous catheters against Klebsiella pneumoniae
    Yorganci, K
    Krepel, C
    Weigelt, JA
    Edmiston, CE
    INTENSIVE CARE MEDICINE, 2002, 28 (04) : 438 - 442
  • [38] Activity of antibacterial impregnated central venous catheters against Klebsiella pneumoniae
    Kaya Yorganci
    Candace Krepel
    John A. Weigelt
    Charles E. Edmiston
    Intensive Care Medicine, 2002, 28 : 438 - 442
  • [39] Comparison of bacterial colonization rates of antiseptic impregnated and pure polymer central venous catheters in the critically ill
    Theaker, C
    Juste, R
    Lucas, N
    Tallboys, C
    Azadian, B
    Soni, N
    JOURNAL OF HOSPITAL INFECTION, 2002, 52 (04) : 310 - 312
  • [40] Anti-microbial or antiseptic impregnated central venous catheters: update on a "central" debate
    dos Santos, CC
    Stewart, TE
    McGeer, A
    INTENSIVE CARE MEDICINE, 2000, 26 (02) : 246 - 249