Automated Computed Tomography Dose-Saving Algorithm to Protect Radiosensitive Tissues Estimation of Radiation Exposure and Image Quality Considerations

被引:34
|
作者
Ketelsen, Dominik [1 ]
Buchgeister, Markus [2 ]
Fenchel, Michael [3 ]
Schmidt, Bernhard [4 ]
Flohr, Thomas G. [4 ]
Syha, Roland [1 ]
Thomas, Christoph [1 ]
Tsiflikas, Ilias [1 ]
Claussen, Claus D. [1 ]
Heuschmid, Martin [1 ]
机构
[1] Univ Hosp Tuebingen, Dept Diagnost & Intervent Radiol, Tubingen, Germany
[2] Beuth Univ Appl Sci, Dept Math Phys & Chem, Berlin, Germany
[3] Univ Hosp Tuebingen, Dept Diagnost & Intervent Neuroradiol, Tubingen, Germany
[4] Siemens Med Solut, Div Computed Tomog, Forchheim, Germany
关键词
XCare; female breast; Alderson RANDO phantom; dose-saving technique; effective dose; MULTIDETECTOR CT; CARDIAC CT; BREAST; MODULATION; REDUCTION; PROTOCOL; CANCER; WOMEN;
D O I
10.1097/RLI.0b013e3182311504
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To evaluate radiation exposure and image quality in thoracic computed tomography (CT) using a new dose-saving algorithm to protect radiosensitive organs. Materials and Methods: For dose measurements, an Alderson RANDO phantom equipped with thermoluminescent dosimeters was used. The effective dose was calculated according to the International Commission on Radiologic Protection 103. Exposure was performed on a second-generation dual-source CT. The following parameters for thoracic CT were used: 160 effective mAs, 120 kV, scan range of 30 cm, collimation of 128 X 0.6 mm. For the acquisition, the tube current modulation type XCare was used, which reduces the tube current for anterior tube position to minimize direct exposure to anterior located organs. To compare differences, scans with and without XCare were performed. Objective signal-to-noise measurements were evaluated, and the subjective noise perception was rated in a 3-point scale (1: excellent, 3: affecting diagnostic accuracy) in 30 patients with a standard thoracic examination and a follow-up using XCare. Results: A substantial dose reduction in radiosensitive tissues was evident using the dose-saving algorithm XCare. Specifically, reductions of 35.2% for the female breast and 20.1% for the thyroid gland were measured, resulting in a decreasing effective whole-body dose of 8.0% and 14.3% for males and females, respectively. The objective and subjective evaluation of image quality showed no significant differences between both scan protocols (P > 0.05). Mean signal-to-noise ratio was 1.3 +/- 0.2 and 1.2 +/- 0.2 in scan protocols without and with XCare, respectively. The subjective scores at the level of the pulmonary trunk were 1.2 +/- 0.4 and 1.4 +/- 0.5 in standard chest scan and scans with the dose-saving algorithm XCare, respectively. Conclusions: The XCare technique protects radiosensitive organs like the female breast and the thyroid gland without affecting image quality. Therefore, this dose-saving algorithm may be used in thoracic CT examinations in male and female patients.
引用
收藏
页码:148 / 152
页数:5
相关论文
共 50 条
  • [1] High-Pitch Computed Tomography Coronary Angiography-A New Dose-Saving Algorithm: Estimation of Radiation Exposure
    Ketelsen, Dominik
    Buchgeister, Markus
    Korn, Andreas
    Fenchel, Michael
    Schmidt, Bernhard
    Flohr, Thomas G.
    Thomas, Christoph
    Schabel, Christoph
    Tsiflikas, Ilias
    Syha, Roland
    Claussen, Claus D.
    Heuschmid, Andmartin
    RADIOLOGY RESEARCH AND PRACTICE, 2012, 2012
  • [2] Radiation dose and image quality in computed tomography
    Prokop, M
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2002, 174 (05): : 631 - 636
  • [3] Radiation dose and image quality with abdominal computed tomography with automated dose-optimized tube voltage selection
    Hu, Lirong
    Wang, Yujun
    Hou, Hongtao
    Wei, Fuquan
    Yang, Guangzhao
    Chen, Yougeng
    JOURNAL OF INTERNATIONAL MEDICAL RESEARCH, 2014, 42 (04) : 1011 - 1017
  • [4] Assessment of Radiation Dose and Image Quality of Multidetector Computed Tomography
    Al Ewaidat, Haytham
    Zheng, Xiaoming
    Khader, Yousef
    Abdelrahman, Mostafa
    Alhasan, Mostafa Khaled Mustafa
    Rawashdeh, Mohammad Ahmmad
    Al Mousa, Dana Samir
    Alawneh, Khaled Zayed Ali
    IRANIAN JOURNAL OF RADIOLOGY, 2018, 15 (03)
  • [5] Radiation Dose and Image Quality in Adult Computed Tomography Scans
    Al Ewaidat, Haytham
    Zheng, Xiaoming
    Khader, Yousef
    Theeb, Mostafa Abdelrahman
    Alhasan, Mostafa Khaled Mustafa
    Rawashdeh, Mohammad Ahmmad
    Al Mousa, Dana Samir
    Alawneh, Khaled Zayed Ali
    JOURNAL OF MEDICAL IMAGING AND HEALTH INFORMATICS, 2018, 8 (02) : 223 - 231
  • [6] Estimation of radiation exposure of different dose saving techniques in 128-slice computed tomography coronary angiography
    Ketelsen, Dominik
    Fenchel, Michael
    Buchgeister, Markus
    Thomas, Christoph
    Boehringer, Nadine
    Tsiflikas, Ilias
    Kaempf, Michael
    Syha, Roland
    Claussen, Claus D.
    Heuschmid, Martin
    EUROPEAN JOURNAL OF RADIOLOGY, 2012, 81 (02) : E153 - E157
  • [7] Image quality and radiation exposure with low-contrast-dose computed tomography angiography of the lower extremities
    Assi, Abed Al Nasser
    POLISH JOURNAL OF RADIOLOGY, 2020, 85 : E169 - E173
  • [8] Optimizing cone-beam computed tomography exposure for an effective radiation dose and image quality balance
    Santos, Ananda Amaral
    Silva, Brunno Santos de Freitas
    Correia, Fernanda Ferreira Nunes
    Mezaiko, Eleazar
    Roriz, Camila Ferro de Souza
    Silva, Maria Alves Garcia
    Freitas, Deborah Queiroz
    Yamamoto-Silva, Fernanda Paula
    IMAGING SCIENCE IN DENTISTRY, 2024, 54 (02) : 159 - 169
  • [9] Development of a computed tomography phantom to evaluate radiation dose and image quality
    Gomez Cardona, Daniel
    Estrada Leon, Edgar Santiago
    Zuluaga Santamaria, Alejandro
    Benitez, Luis
    Ramirez Giraldo, Juan Carlos
    2013 PAN AMERICAN HEALTH CARE EXCHANGES (PAHCE), 2013,
  • [10] Image Quality in Computed Tomography Coronary Angiography and Radiation Dose Reduction
    Golubickas, Domas
    Lukosevicius, Saulius
    Tamakauskas, Vytenis
    Dobrovolskiene, Laima
    Baseviciene, Ingrida
    Grib, Liviu
    Ragaisyte, Nijole
    Leonavicius, Rytis
    Medvedev, Viktor
    Veikutis, Vincentas
    INFORMATICA, 2021, 32 (04) : 741 - 757