The level of detail required in a deformable phantom to accurately perform quality assurance of deformable image registration

被引:7
|
作者
Saenz, Daniel L. [1 ]
Kim, Hojin [2 ]
Chen, Josephine [2 ]
Stathakis, Sotirios [1 ]
Kirby, Neil [1 ]
机构
[1] Univ Texas Hlth Sci Ctr San Antonio, San Antonio, TX 78229 USA
[2] Univ Calif San Francisco, San Francisco, CA 94143 USA
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2016年 / 61卷 / 17期
关键词
deformable image registration; quality assurance; deformable phantoms; CT; RADIOTHERAPY; ALGORITHM;
D O I
10.1088/0031-9155/61/17/6269
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The primary purpose of the study was to determine how detailed deformable image registration (DIR) phantoms need to adequately simulate human anatomy and accurately assess the quality of DIR algorithms. In particular, how many distinct tissues are required in a phantom to simulate complex human anatomy? Pelvis and head-and-neck patient CT images were used for this study as virtual phantoms. Two data sets from each site were analyzed. The virtual phantoms were warped to create two pairs consisting of undeformed and deformed images. Otsu's method was employed to create additional segmented image pairs of n distinct soft tissue CT number ranges (fat, muscle, etc). A realistic noise image was added to each image. Deformations were applied in MIM Software (MIM) and Velocity deformable multi-pass (DMP) and compared with the known warping. Images with more simulated tissue levels exhibit more contrast, enabling more accurate results. Deformation error (magnitude of the vector difference between known and predicted deformation) was used as a metric to evaluate how many CT number gray levels are needed for a phantom to serve as a realistic patient proxy. Stabilization of the mean deformation error was reached by three soft tissue levels for Velocity DMP and MIM, though MIM exhibited a persisting difference in accuracy between the discrete images and the unprocessed image pair. A minimum detail of three levels allows a realistic patient proxy for use with Velocity and MIM deformation algorithms.
引用
收藏
页码:6269 / 6280
页数:12
相关论文
共 50 条
  • [41] A Multi-Phase Cross-Modality Deformable Bio-Tissue Phantom for Deformable Image Registration Validation
    Qin, A.
    Snyder, M.
    Liu, M.
    Ding, X.
    Zheng, W.
    Liu, Q.
    Chen, S.
    Liang, J.
    Yan, D.
    MEDICAL PHYSICS, 2020, 47 (06) : E406 - E406
  • [42] Evaluation of Diffeomorphic Demons Algorithm for Deformable Image Registration Using Virtual Phantom
    Reiazi, R.
    Mohammadi, R.
    Mahdavi, S. R.
    MEDICAL PHYSICS, 2018, 45 (06) : E228 - E228
  • [43] Technical Note: Intensity-based quality assurance criteria for deformable image registration in image-guided radiotherapy
    Bosma, Lando S.
    Zachiu, Cornel
    Denis de Senneville, Baudouin
    Raaymakers, Bas W.
    Ries, Mario
    MEDICAL PHYSICS, 2023, 50 (09) : 5715 - 5722
  • [44] Quantification of the Low Field MRI Image Quality for Deformable Registration
    Boehnke, E.
    Han, F.
    Hu, P.
    Yang, Y.
    Sheng, K.
    MEDICAL PHYSICS, 2017, 44 (06) : 3143 - 3143
  • [45] Semi-automated quality assurance of deformable registration in CT radiotherapy data
    Mcgrath, T.
    Lawrence, Z.
    Salih, R. Farhad
    Peters, Y.
    Rawling, J.
    Wilson, M.
    Piazzese, C.
    Holloway, S.
    RADIOTHERAPY AND ONCOLOGY, 2019, 133 : S1171 - S1171
  • [46] On the use of deformable image registration to evaluate the need to perform ART in head and neck cancer
    Delgado-Tapia, P.
    Lizondo, M.
    Latorre-Musoll, A.
    Jornet, N.
    Eudaldo, T.
    Carrasco, P.
    Ruiz-Martinez, A.
    Cases, C.
    Ribas, M.
    RADIOTHERAPY AND ONCOLOGY, 2016, 119 : S853 - S854
  • [47] Deformable image registration in radiation therapy
    Dowling, Jason A.
    O'Connor, Laura M.
    JOURNAL OF MEDICAL RADIATION SCIENCES, 2020, 67 (04) : 257 - 259
  • [48] Deformable image registration based on elastodynamics
    Ahmad, Sahar
    Khan, Muhammad Faisal
    MACHINE VISION AND APPLICATIONS, 2015, 26 (05) : 689 - 710
  • [49] Dynamic meshing for deformable image registration
    Cai, Yiqi
    Guo, Xiaohu
    Zhong, Zichun
    Mao, Weihua
    COMPUTER-AIDED DESIGN, 2015, 58 : 141 - 150
  • [50] Deformable image registration with geometric changes
    Yu Liu
    Bo Zhu