The level of detail required in a deformable phantom to accurately perform quality assurance of deformable image registration

被引:7
|
作者
Saenz, Daniel L. [1 ]
Kim, Hojin [2 ]
Chen, Josephine [2 ]
Stathakis, Sotirios [1 ]
Kirby, Neil [1 ]
机构
[1] Univ Texas Hlth Sci Ctr San Antonio, San Antonio, TX 78229 USA
[2] Univ Calif San Francisco, San Francisco, CA 94143 USA
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2016年 / 61卷 / 17期
关键词
deformable image registration; quality assurance; deformable phantoms; CT; RADIOTHERAPY; ALGORITHM;
D O I
10.1088/0031-9155/61/17/6269
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The primary purpose of the study was to determine how detailed deformable image registration (DIR) phantoms need to adequately simulate human anatomy and accurately assess the quality of DIR algorithms. In particular, how many distinct tissues are required in a phantom to simulate complex human anatomy? Pelvis and head-and-neck patient CT images were used for this study as virtual phantoms. Two data sets from each site were analyzed. The virtual phantoms were warped to create two pairs consisting of undeformed and deformed images. Otsu's method was employed to create additional segmented image pairs of n distinct soft tissue CT number ranges (fat, muscle, etc). A realistic noise image was added to each image. Deformations were applied in MIM Software (MIM) and Velocity deformable multi-pass (DMP) and compared with the known warping. Images with more simulated tissue levels exhibit more contrast, enabling more accurate results. Deformation error (magnitude of the vector difference between known and predicted deformation) was used as a metric to evaluate how many CT number gray levels are needed for a phantom to serve as a realistic patient proxy. Stabilization of the mean deformation error was reached by three soft tissue levels for Velocity DMP and MIM, though MIM exhibited a persisting difference in accuracy between the discrete images and the unprocessed image pair. A minimum detail of three levels allows a realistic patient proxy for use with Velocity and MIM deformation algorithms.
引用
收藏
页码:6269 / 6280
页数:12
相关论文
共 50 条
  • [1] Quality Assurance of Deformable Image Registration in Radiotherapy
    Watkins, W. T.
    Bzdusek, K.
    Siebers, J. V.
    MEDICAL PHYSICS, 2014, 41 (06) : 399 - 399
  • [2] Development of a dynamic deformable thorax phantom for the quality management of deformable image registration
    Sugawara, Yasuharu
    Kadoya, Noriyuki
    Kotabe, Kazuki
    Nakajima, Yujiro
    Ikeda, Ryutaro
    Tanabe, Shunpei
    Ohashi, Haruna
    Jingu, Keiichi
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2020, 77 : 100 - 107
  • [3] Quality assurance of deformable image registration for bowel motility quantification
    Nelissen, K. J.
    Barten, D. L. J.
    Laan, J. J.
    Westerveld, H.
    Bel, A.
    Van Kesteren, Z.
    RADIOTHERAPY AND ONCOLOGY, 2020, 152 : S958 - S958
  • [4] Tools and recommendations for commissioning and quality assurance of deformable image registration in radiotherapy
    Bosma, Lando
    RADIOTHERAPY AND ONCOLOGY, 2024, 194 : S124 - S124
  • [5] Biomechanical quality assurance criteria for deformable registration in image guided radiotherapy
    Zachiu, C.
    de Senneville, B. Denis
    Ries, M.
    Raaymakers, B. W.
    RADIOTHERAPY AND ONCOLOGY, 2020, 152 : S310 - S311
  • [6] Tools and recommendations for commissioning and quality assurance of deformable image registration in radiotherapy
    Bosma, Lando S.
    Hussein, Mohammad
    Jameson, Michael G.
    Asghar, Soban
    Brock, Kristy K.
    McClelland, Jamie R.
    Poeta, Sara
    Yuen, Johnson
    Zachiu, Cornel
    Yeo, Adam U.
    PHYSICS & IMAGING IN RADIATION ONCOLOGY, 2024, 32
  • [7] Building Deformation Error Histogram and Quality Assurance of Deformable Image Registration
    Park, S. B.
    Kim, H.
    Yao, M.
    Ellis, R.
    Machtay, M.
    Sohn, J. W.
    MEDICAL PHYSICS, 2012, 39 (06) : 3672 - 3672
  • [8] Deformable Image Registration Quality Assurance using Deep Learning Segmentation
    Mullins, Joel
    Wilson, Byron
    MEDICAL PHYSICS, 2022, 49 (08) : 5675 - 5675
  • [9] Quality assurance criteria and anatomically plausible models for deformable image registration
    Zachiu, C.
    de Senneville, B. Denis
    Raaymakers, B.
    RADIOTHERAPY AND ONCOLOGY, 2019, 133 : S1093 - S1093
  • [10] Robust quality assurance criteria for deformable image registration for adaptive radiotherapy
    Bosma, L.
    Zachiu, C.
    de Senneville, B. Denis
    Raaymakers, B.
    Ries, M.
    RADIOTHERAPY AND ONCOLOGY, 2021, 161 : S323 - S324