A New Columnar CsI(Tl) Scintillator for iQID detectors

被引:9
|
作者
Han, Ling [1 ]
Miller, Brian W. [1 ,3 ]
Barber, H. Bradford [1 ,2 ]
Nagarkar, Vivek V. [4 ]
Furenlid, Lars R. [1 ,2 ]
机构
[1] Univ Arizona, Coll Opt Sci, Tucson, AZ 85721 USA
[2] Univ Arizona, Dept Med Imaging, CGRI, Tucson, AZ 85721 USA
[3] Pacific NW Natl Lab, Richland, WA 99352 USA
[4] Radiat Monitoring Devices Inc, Watertown, MA 02472 USA
关键词
Columnar CsI(Tl); thick scintillator; iQID detector; sensitivity; resolution; depth of interaction; noise discrimination; frame parsing;
D O I
10.1117/12.2066179
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A 1650 mu m thick columnar CsI(Tl) scintillator for upgrading iQID detectors, which is a high-resolution photon-counting gamma-ray and x-ray detector recently developed at the Center for Gamma-Ray Imaging (CGRI), has been studied in terms of sensitivity, spatial resolution and depth-of-interaction effects. To facilitate these studies, a new frame-parsing algorithm for processing raw event data is also proposed that has more degrees of freedom in data processing and can discriminate against a special kind of noise present in some low-cost intensifiers. The results show that in comparison with a 450 mu m-thickness columnar CsI(Tl) scintillator, the 1650 mu m thick CsI(Tl) scintillator provides more than twice the sensitivity at the expense of some spatial resolution degradation. The depth-of-interaction study also shows that event size and amplitude vary with scintillator thickness, which can assist in future detector simulations and 3D-interaction-position estimation.
引用
收藏
页数:10
相关论文
共 50 条
  • [41] A Study of CsI(Tl) Scintillator with Optimized Conditions of Large Area Avalanche Photodiode
    Kim, Minjeong
    Kang, Heedong
    Kim, H. J.
    Kim, Wan
    Park, H.
    Kim, Sunghwan
    JOURNAL OF NUCLEAR SCIENCE AND TECHNOLOGY, 2008, : 586 - 589
  • [42] Portal imaging with a CsI(Tl) transparent scintillator x-ray detector
    Zeman, HD
    Samant, SS
    Lovhoiden, G
    Weinberg, B
    Sawant, A
    PHYSICS OF MEDICAL IMAGING, 1998, 3336 : 175 - 186
  • [43] Energy and position reconstruction on CsI(Tl) scintillator detector array in TEXONO experiment
    Zhu, Yue-Feng
    Li, Yu-Lan
    Wong, Henry Tsz-King
    Li, Jin
    Singh, Venktesh
    Lin, Shin-Ted
    Kao Neng Wu Li Yu Ho Wu Li/High Energy Physics and Nuclear Physics, 2005, 29 (03): : 288 - 294
  • [44] Particle identification method in the CsI(Tl) scintillator used for the CHIMERA 4π detector
    Alderighi, M
    Anzalone, A
    Basssini, R
    Berceanu, I
    Blicharska, J
    Boiano, C
    Borderie, B
    Bougault, R
    Bruno, M
    Cali, C
    Cardella, G
    Cavallaro, S
    D'Agostino, M
    D'Andrea, M
    Dayras, R
    De Filippo, E
    Fichera, F
    Geraci, E
    Giustolisi, F
    Grzeszczuk, A
    Guardone, N
    Guazzoni, P
    Guinet, D
    Iacono-Manno, CM
    Kowalski, S
    La Guidara, E
    Lanchais, AL
    Lanzalone, G
    Lanzanó, G
    Le Neindre, N
    Li, S
    Maiolino, C
    Majka, Z
    Manfredi, G
    Nicotra, D
    Paduszynski, T
    Pagano, A
    Papa, M
    Petrovici, CM
    Piasecki, E
    Pirrone, S
    Politi, G
    Pop, A
    Porto, F
    Rivet, MF
    Rosato, E
    Saccá, G
    Sechi, G
    Simion, V
    Sperduto, ML
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2002, 489 (1-3): : 257 - 265
  • [45] Improvement of the sensitivity and spatial resolution of pixelated CsI:Tl scintillator with reflective coating
    Cha, Bo Kyung
    Bae, Jun Hyung
    Lee, Chae-hun
    Jeon, Hosang
    Kim, Hyunduk
    Chang, Sungho
    Kang, Bo-Sun
    Cho, Gyuseong
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2009, 607 (01): : 145 - 149
  • [46] Gamma ray spectroscopy with CsI(Tl) scintillator coupled to silicon drift chamber
    Fiorini, C
    Longoni, A
    Perotti, F
    Labanti, C
    Lechner, P
    Struder, L
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1997, 44 (06) : 2553 - 2560
  • [47] Experiments on high excitation density, quenching, and radiative kinetics in CsI:Tl scintillator
    Grim, Joel Q.
    Li, Qi
    Ucer, K. B.
    Williams, R. T.
    Moses, W. W.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2011, 652 (01): : 284 - 287
  • [48] Energy & position reconstruction on CsI(Tl) scintillator detector array in TEXONO experiment
    Zhu, YF
    Li, YL
    Wong, HTK
    Li, J
    Venktesh, S
    Lin, ST
    HIGH ENERGY PHYSICS AND NUCLEAR PHYSICS-CHINESE EDITION, 2005, 29 (03): : 288 - 294
  • [49] Fabrication and Performance of Columnar CsI(Tl) Scintillation Films With Single Preferred Orientation
    Yao, Dalin
    Gu, Mu
    Liu, Xiaolin
    Huang, Shiming
    Liu, Bo
    Ni, Chen
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2013, 60 (03) : 1632 - 1636
  • [50] Comparison of pulse shape discrimination methods for phoswich and CsI:Tl detectors
    Chandrikamohan, Pramoth
    Devol, Timothy A.
    2005 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2005, : 1351 - 1355