The voltammetric sensor for sensitive determination of 8-hydroxyquinoline based on MWNTs/Nafion/GCE

被引:0
|
作者
Zhou Yuanyuan [1 ]
Li Song [2 ]
机构
[1] N China Univ Water Resources & Elect Power, Inst Environm & Municipal Engn, Zhengzhou, Peoples R China
[2] N China Univ Water Resources & Elect power, Inst Elect Power, Zhengzhou 450011, Peoples R China
关键词
Multi-wall carbon nanotubes; Nafion; Coliforms; Amperometric detection; PERFORMANCE LIQUID-CHROMATOGRAPHY; GLASSY-CARBON ELECTRODE; NANOTUBES; BIOSENSORS; ROUTE; FILM;
D O I
暂无
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
A multiwall carbon nanotube/Nafion composite modified glassy carbon electrode (MWNT/Nafion/GCE) was prepared and characterized by Atomic Force Microscopy (AFM) and Transmission Electron Microscope(TEM). This voltammetric sensor exhibited strong catalytic effect toward the oxidation of 8- hydroxyquinoline(8-HQ) in HAc-NaAc buffer solution (0.2M, pH 3.6). A new analytical method for determining 8-HQ was established. Under the optimized condition, the anodic peak current was linear with the concentration of 8-HQ in the range of 2x10(-8)similar to 1.0x10(-5)M with a detection limit of 9x10(-9) M. The practical application of MWNT/Nafion/GCE was carried out for determining 8-HQ in cosmetic sample with satisfactory results. The number of electron and proton taking part in the reaction was calculated, and then the electrode reaction mechanism was confirmed by UV-vis spectra.
引用
收藏
页码:924 / 927
页数:4
相关论文
共 50 条
  • [31] EXTRACTION AND SPECTROPHOTOMETRIC DETERMINATION OF VANADIUM(V) WITH 8-HYDROXYQUINOLINE
    KURMAIAH, N
    SATYANARAYANA, D
    RAO, VPR
    TALANTA, 1967, 14 (04) : 495 - +
  • [32] SUBSTOICHIOMETRIC DETERMINATION OF LANTHANUM BY USING EDTA AND 8-HYDROXYQUINOLINE
    KATOH, M
    KUDO, K
    JOURNAL OF RADIOANALYTICAL CHEMISTRY, 1983, 79 (01): : 23 - 34
  • [33] THE PHOTOMETRIC DETERMINATION OF SMALL AMOUNTS OF TITANIUM WITH 8-HYDROXYQUINOLINE
    GARDNER, K
    ANALYST, 1951, 76 (905) : 485 - 488
  • [34] Volumetric determination of iron and aluminum in cement with 8-hydroxyquinoline
    Kampf, L
    INDUSTRIAL AND ENGINEERING CHEMISTRY-ANALYTICAL EDITION, 1941, 13 : 0072 - 0073
  • [35] THE USE OF 8-HYDROXYQUINOLINE FOR THE COLORIMETRIC DETERMINATION OF ALUMINUM IN STEEL
    WIBERLEY, SE
    BASSETT, LG
    ANALYTICAL CHEMISTRY, 1948, 20 (03) : 279 - 279
  • [36] Synthesis, spectroscopic and voltammetric studies of a novel dioxovanadate(V) 8-hydroxyquinoline complex
    Çakir, S
    Biçer, E
    Naumov, P
    Çakir, O
    JOURNAL OF COORDINATION CHEMISTRY, 2002, 55 (12) : 1461 - 1471
  • [37] A pH-Sensitive Lignin-Based Material for Sustained Release of 8-Hydroxyquinoline
    Zheng, Qian
    Chai, Lanfang
    Du, Boyu
    Li, Wei
    Fu, Lian-Hua
    Chen, Xiaohong
    POLYMERS, 2023, 15 (08)
  • [38] A novel 8-hydroxyquinoline PVC coated graphite sensor for potentiometric determination of some metal ions
    Arida, HAM
    ANALYTICAL LETTERS, 2002, 35 (15) : 2421 - 2431
  • [39] A ratiometric fluorescent sensor for Ag+ based on 8-hydroxyquinoline platform in aqueous media
    Xu, Huajie
    Liu, Zhaodi
    Sheng, Liangquan
    Huang, Deqian
    Zhang, Hong
    Song, Chongfu
    Chen, Mingming
    Hua, Wuyang
    ANALYTICAL METHODS, 2013, 5 (12) : 2929 - 2932
  • [40] Highly sensitive and selective electrochemical sensor based on high-quality graphene/nafion nanocomposite for voltammetric determination of nebivolol
    Er, Engin
    Celikkan, Huseyin
    Erk, Nevin
    SENSORS AND ACTUATORS B-CHEMICAL, 2016, 224 : 170 - 177