Novel calibration and lens distortion correction of 3D reconstruction systems

被引:8
|
作者
Jin, S. Q. [1 ]
Fan, L. Q. [1 ]
Liu, Q. Y. [1 ]
Lu, R. S. [1 ]
机构
[1] HFUT, Sch Instrument Sci & Optoelect Engn, Hefei 230009, Anhui, Peoples R China
关键词
D O I
10.1088/1742-6596/48/1/067
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A novel calibration and lens distortion correction of 3D reconstruction systems is introduced in this paper. Assuming zero distortion at the center of image, the parameter calibration and lens distortion correction of CCD camera and DLP projector is separated with the points in center and all the rest points. Furthermore, identification and correspondence of the interest points is done automatically because of the designed target with standard circles and multicolor code of pseudo-random array during the calibration. The experiments show that it is a fast and convenient method to carry out the calibration for lens distortion.
引用
收藏
页码:359 / 363
页数:5
相关论文
共 50 条
  • [41] A Novel Calibration Board and Experiments for 3D LiDAR and Camera Calibration
    Cai, Huaiyu
    Pang, Weisong
    Chen, Xiaodong
    Wang, Yi
    Liang, Haolin
    SENSORS, 2020, 20 (04)
  • [42] Novel 3D bioprinting for urethral reconstruction
    Ekerhult, Olsen A. T.
    Ortac, M.
    Nie, W.
    Mahajan, N.
    Zhao, W.
    Chandra, P.
    Atala, A.
    EUROPEAN UROLOGY, 2024, 85 : S1988 - S1988
  • [43] Investigation of a 3D system distortion correction method for MR images
    Stanescu, Teodor
    Jans, Hans-Sonke
    Wachowicz, Keith
    Fallone, B. Gino
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2010, 11 (01): : 200 - 216
  • [44] Detection and correction of geometric distortion in 3D CT/MR images
    Breeuwer, M
    Zylka, W
    Wadley, J
    Falk, A
    CARS '99: COMPUTER ASSISTED RADIOLOGY AND SURGERY, 1999, 1191 : 78 - 82
  • [45] A phantom based framework for MR distortion detection and correction in 3D
    Alasti, H.
    Qiu, J.
    Near, J.
    Kirilova, A.
    Affray, D.
    RADIOTHERAPY AND ONCOLOGY, 2007, 84 : S95 - S95
  • [46] Automatic image alignment and distortion correction for 3D microscope imagery
    Biggs, DSC
    He, YB
    Holmes, TJ
    MOLECULAR BIOLOGY OF THE CELL, 2001, 12 : 260A - 260A
  • [47] THE DISTORTION OF MEW PATTERNS BY 3D COLLECTORS: INVESTIGATION, QUANTIFICATION AND CORRECTION
    O'Connell, Cathal D.
    Antill-O'Brien, Natasha
    Doyle, Stephanie
    Onofrillo, Carmine
    Duchi, Serena
    Di Bella, Claudia
    TISSUE ENGINEERING PART A, 2022, 28 : S134 - S134
  • [48] Camera calibration for 3D reconstruction: application to the measure of 3D deformations on sheet metal parts
    Orteu, JJ
    Garric, V
    Devy, M
    NEW IMAGE PROCESSING TECHNIQUES AND APPLICATIONS: ALGORITHMS, METHODS, AND COMPONENTS II, 1997, 3101 : 252 - 263
  • [49] A novel calibration system for the plant 3d scanner
    Xu, Shengyong
    Dehua, L.
    Zhu, Li
    International Journal of Advancements in Computing Technology, 2012, 4 (10) : 45 - 53
  • [50] Calibration Targets and Standards for 3D Lidar Systems
    Miles, Brian H.
    Kamerman, Gary W.
    Fronek, Donald K.
    Eadon, Paul
    LASER RADAR TECHNOLOGY AND APPLICATIONS XV, 2010, 7684