Fracture resistance of all-ceramic and metal-ceramic inlays

被引:0
|
作者
Esquivel-Upshaw, JF
Anusavice, KJ
Reid, M
Yang, MCK
Lee, RB
机构
[1] Univ Florida, Coll Dent, Dept Prosthodont, Gainesville, FL 32610 USA
[2] Univ Florida, Coll Dent, Dept Dent Biomat, Gainesville, FL 32610 USA
[3] Univ Florida, Coll Dent, Dept Stat, Gainesville, FL 32610 USA
[4] Univ Florida, Coll Dent, Div Biostat, Gainesville, FL 32610 USA
[5] Univ Florida, Coll Dent, Dept Biostat, Gainesville, FL 32610 USA
关键词
D O I
暂无
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: Metal-ceramic inlay designs were developed to determine if the esthetic qualities of all-ceramic inlays could be duplicated and at the same time improve their strength and stability. The objectives of this study were to: (1) compare the fracture resistance of metal-ceramic inlays with that of all-ceramic inlays; (2) determine the correlation between the degree of preparation taper and fracture resistance; and (3) determine the correlation between marginal gap width and fracture resistance. Materials and Methods: Inlay preparations were made on 60 Dentoform teeth, with 30 teeth allocated for metal-ceramic inlays and 30 teeth for all-ceramic inlays. Each group was further subdivided into 5-, 10-, and 20-degree taper preparations. Metal-ceramic inlays were fabricated using Goldtech Bio 2000 metal and Ceramco porcelain extending to the margin, while all-ceramic inlays were made from Empress II ceramic. Marginal gap widths were measured at six critical areas after fabrication. The load at failure was measured using an Instron Universal Testing Machine. Results: The mean fracture load for all-ceramic inlays and metal-ceramic inlays at 5, 10, and 20 degrees was 70 +/- 40 N, 48 +/- 37 N, 33 +/- 7 N, and 40 +/- 23 N, 29 +/- 22 N, and 14 +/- 4 N, respectively. The mean gap width was 105 mum and 126 mum for all-ceramic and metal-ceramic inlays, respectively. Conclusion: The mean fracture load for Empress inlays was significantly higher than that for metal-ceramic inlays. Inlays with a 5-degree taper were significantly more fracture resistant than those with a 20-degree taper. There was no relation between marginal gap width and fracture resistance.
引用
收藏
页码:109 / 114
页数:6
相关论文
共 50 条
  • [41] Comparative Assessment of the Functional Parameters for Metal-Ceramic and All-Ceramic Teeth Restorations in Prosthetic Dentistry-A Literature Review
    Ispas, Ana
    Iosif, Laura
    Popa, Daniela
    Negucioiu, Marius
    Constantiniuc, Mariana
    Bacali, Cecilia
    Buduru, Smaranda
    BIOLOGY-BASEL, 2022, 11 (04):
  • [42] Replacing an anterior, metal-ceramic restoration with an all-ceramic resin-bonded fixed partial denture: A case report
    Ozyesil, Atilla Gokhan
    Kalkan, Mustafa
    JOURNAL OF ADHESIVE DENTISTRY, 2006, 8 (04): : 263 - 266
  • [43] Fracture resistance of five different metal framework designs for metal-ceramic restorations
    Ulusoy, M
    Toksavul, S
    INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2002, 15 (06) : 571 - 574
  • [44] Fracture resistance of teeth restored with composite and ceramic inlays
    Mehl, A
    Folwaczny, M
    Hickel, R
    JOURNAL OF DENTAL RESEARCH, 2002, 81 : B258 - B258
  • [45] Strength and fracture toughness of ceramic materials for metal-ceramic prosthetic dentistry
    Ostrovoi D.Yu.
    Gogotsi G.A.
    Gorban' S.A.
    Oshkaderov S.P.
    Stepkin V.I.
    Bobokal A.N.
    Strength of Materials, 2005, 37 (3) : 323 - 330
  • [46] EVALUATION OF MARGINAL ADAPTATION OF ALL-CERAMIC CROWNS AND METAL CERAMIC CROWNS
    VAHIDI, F
    EGLOFF, ET
    PANNO, FV
    JOURNAL OF PROSTHETIC DENTISTRY, 1991, 66 (04): : 426 - 431
  • [47] The effect of alumina core thickness on the fracture resistance of All-Ceramic crowns.
    Abed, HM
    Razzoog, ME
    Lang, BR
    Yaman, P
    JOURNAL OF DENTAL RESEARCH, 1997, 76 : 394 - 394
  • [48] Resistance to fracture of two all-ceramic crown materials following endodontic access
    Wood, KC
    Berzins, DW
    Luo, Q
    Thompson, GA
    Toth, JM
    Nagy, WW
    JOURNAL OF PROSTHETIC DENTISTRY, 2006, 95 (01): : 33 - 41
  • [49] Effect of connector design on the fracture resistance of all-ceramic fixed partial dentures
    Oh, WS
    Anusavice, KJ
    JOURNAL OF PROSTHETIC DENTISTRY, 2002, 87 (05): : 536 - 542
  • [50] The effect of luting media on the fracture resistance of a flame sprayed all-ceramic crown
    Casson, AM
    Jones, JCG
    Youngson, CC
    Wood, DJ
    JOURNAL OF DENTISTRY, 2001, 29 (08) : 539 - 544