Characteristics of Multiwall Carbon Nanotubes for an Intratracheal Instillation Study with Rats

被引:13
|
作者
Takaya, Mitsutoshi [1 ]
Serita, Fumio [1 ]
Yamazaki, Kazunori [2 ]
Aiso, Shigetoshi [2 ]
Kubota, Hisayo [1 ]
Asakura, Masumi [2 ]
Ikawa, Naoki [2 ]
Nagano, Kasuke [2 ]
Arito, Heihachiro [2 ]
Fukushima, Shoji [2 ]
机构
[1] Natl Inst Occupat Safety & Hlth, Tama Ku, Kanagawa 2148585, Japan
[2] Japan Ind Safety & Hlth Assoc, Japan Bioassay Res Ctr, Kanagawa 2570015, Japan
关键词
Multiwall carbon nanotube; Metal impurities; Iron; SEM; Dynamic light scattering; Size distribution; Dose characterization; ASBESTOS; MESOTHELIOMA; INDUCTION; TOXICITY; EXPOSURE; MOUSE; FUMES;
D O I
10.2486/indhealth.MS1128
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Much concern has been raised over the health consequences of workers exposed to carbon nanotubes. In order to characterize multi-wall carbon nanotubes (MWCNT) suspended in a phosphate-buffered saline containing 0.1% Tween 80 for an intratracheal instillation study. Length and width distributions of the MWCNT fibers, dispersion of MWCNT in the suspension and in the lung tissue and the MWCNT contents of metal impurities were investigated. Arithmetic mean length and width of the MWCNT fibers as measured on scanning electron microscope (SEM) photographs were 5.0 mu m and 88 nm, respectively, and fibers longer than 5.0 mu m were 38.9% of all fibers measured. Dynamic light scattering size measurement revealed that 5-min ultrasonication, together with addition of Tween 80 into the suspension, decreased the hydrodynamic diameters of the agglomerated MWCNT to those of liner particles below 1.0 mu m. SEM observation showed good dispersion of MWCNT in the suspension, and in the alveoli on Day 1 after instillation. Concentration of iron, chromium and nickel in the MWCNT were 4,400, 48 and 17 ppm (wt/wt), respectively, all of which were below levels that would elicit positive pulmonary toxic responses to these metals. The results suggest that well-dispersed, long and thin MWCNT fibers exhibit asbestos-like pathogenicity in the lung.
引用
收藏
页码:452 / 459
页数:8
相关论文
共 50 条
  • [41] Assessment of the toxicity and carcinogenicity of double-walled carbon nanotubes in the rat lung after intratracheal instillation: a two-year study
    Dina Mourad Saleh
    Shengyong Luo
    Omnia Hosny Mohamed Ahmed
    David B. Alexander
    William T. Alexander
    Sivagami Gunasekaran
    Ahmed M. El-Gazzar
    Mohamed Abdelgied
    Takamasa Numano
    Hiroshi Takase
    Makoto Ohnishi
    Susumu Tomono
    Randa Hussein Abd el Hady
    Katsumi Fukamachi
    Jun Kanno
    Akihiko Hirose
    Jiegou Xu
    Shugo Suzuki
    Aya Naiki-Ito
    Satoru Takahashi
    Hiroyuki Tsuda
    Particle and Fibre Toxicology, 19
  • [42] Pulmonary toxicity of single-wall carbon nanotubes in mice 7 and 90 days after intratracheal instillation
    Lam, CW
    James, JT
    McCluskey, R
    Hunter, RL
    TOXICOLOGICAL SCIENCES, 2004, 77 (01) : 126 - 134
  • [43] A Pleural Effusion Model in Rats by Intratracheal Instillation of Polyacrylate/Nanosilica
    Cao, Wen
    Zhu, Xiaoli
    Tang, Ziren
    Song, Yuguo
    JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2019, (146):
  • [44] Lung burden of cellulose nanofibrils in rats following intratracheal instillation
    Fujita, K.
    Obara, S.
    Maru, J.
    Endoh, S.
    TOXICOLOGY LETTERS, 2023, 384 : S264 - S264
  • [45] Functional neurophysiological alterations caused by intratracheal instillation of manganese in rats
    Mate, Zs
    Szabo, A.
    Hermesz, E.
    Jancso, Zs
    ACTA PHYSIOLOGICA HUNGARICA, 2010, 97 (04) : 456 - 457
  • [46] Pulmonary toxicity of well-dispersed multi-wall carbon nanotubes following inhalation and intratracheal instillation
    Morimoto, Yasuo
    Hirohashi, Masami
    Ogami, Akira
    Oyabu, Takako
    Myojo, Toshihiko
    Todoroki, Motoi
    Yamamoto, Makoto
    Hashiba, Masayoshi
    Mizuguchi, Yohei
    Lee, Byeong Woo
    Kuroda, Etsushi
    Shimada, Manabu
    Wang, Wei-Ning
    Yamamoto, Kazuhiro
    Fujita, Katsuhide
    Endoh, Shigehisa
    Uchida, Kunio
    Kobayashi, Norihiro
    Mizuno, Kohei
    Inada, Masaharu
    Tao, Hiroaki
    Nakazato, Tetsuya
    Nakanishi, Junko
    Tanaka, Isamu
    NANOTOXICOLOGY, 2012, 6 (06) : 587 - 599
  • [47] Bioavailability and metabolism of hydroquinone after intratracheal instillation in male rats
    Deisinger, PJ
    English, JC
    DRUG METABOLISM AND DISPOSITION, 1999, 27 (04) : 442 - 448
  • [48] Intershell resistance in multiwall carbon nanotubes: A Coulomb drag study
    Lunde, AM
    Flensberg, K
    Jauho, AP
    PHYSICAL REVIEW B, 2005, 71 (12)
  • [49] A Study of Hydrogen Accumulation in Multiwall Carbon Nanotubes by Electrochemical Techniques
    L. E. Tsygankova
    V. I. Vigdorovich
    A. A. Zvereva
    V. I. Kichigin
    Protection of Metals and Physical Chemistry of Surfaces, 2016, 52 : 211 - 217
  • [50] Theoretical and numerical study of torsional buckling of multiwall carbon nanotubes
    Han, Q
    Yao, XH
    Li, LF
    MECHANICS OF ADVANCED MATERIALS AND STRUCTURES, 2006, 13 (04) : 329 - 337