Shaking table test of a prefabricated steel frame structure with all-bolted connections

被引:17
|
作者
Zhang, Ailin [1 ]
Xie, Zhiqiang [1 ]
Zhang, Yanxia [1 ]
Lin, Haipeng [1 ]
机构
[1] Beijing Univ Civil Engn & Architecture, Sch Civil & Transportat Engn, Beijing, Peoples R China
基金
中国国家自然科学基金;
关键词
ABPSFS; Shaking table test; Seismic responses; Dynamic failure mechanism of CBFC; Performance objective; TO-COLUMN CONNECTIONS; SEISMIC PERFORMANCE; FLANGE CONNECTIONS; PLATE CONNECTIONS; BEHAVIOR;
D O I
10.1016/j.engstruct.2021.113273
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
To study the seismic performance of an all bolt-connected prefabricated steel frame structure (ABPSFS), a shaking table test was conducted of a 1:4 scaled ABPSFS model in which high-strength bolts were used for column-to-column and beam-to-column connections. The dynamic properties, seismic responses, and failure mechanisms of the ABPSFS under different peak ground accelerations (PGAs) were analysed. This research also examined the dynamic failure mechanism of column-to-column bolted flange connections and proposed corresponding performance objectives in the seismic design of ABPSFS. The results indicated that the failure modes of ABPSFS were the warping of flange plates, the slipping of washers in bolted joints, and the cracking of concrete floors. With an increase in PGA, the fundamental frequency and stiffness of the structural model decreased while the damping ratio increased. The splicing layer became the weak layer of the entire structure and its acceleration amplification coefficient significantly increased in line with PGA. The dynamic failure mechanism of column-tocolumn bolted flange connection (CBFC) was buckling of the flange plate, opening of flange gap, and bolt fracture. For ABPSFS, 1/350 rad is recommended as the elastic storey drift angle and 1/70 rad as the elastic-plastic storey drift angle.
引用
收藏
页数:16
相关论文
共 50 条
  • [41] Shaking table test study on seismic performance of RC frame structure with NES
    Yang, Haixu
    Li, Zhuo
    Wang, Haibiao
    Zhang, Maohua
    Ni, Songyuan
    STRUCTURES, 2023, 47 : 153 - 164
  • [42] Research on shaking table test of frame structure crossing the ground fissure with braces
    Xiong Z.-M.
    Chen X.
    Wang Y.
    Xiong W.-Y.
    Zhang C.
    Gongcheng Lixue/Engineering Mechanics, 2019, 36 (10): : 86 - 95
  • [43] Shaking Table Test of the External Shear Wall and Internal Frame RC Structure
    Gong Y.
    Wang B.
    Gan T.
    Zhou Q.
    Jiang L.
    Tianjin Daxue Xuebao (Ziran Kexue yu Gongcheng Jishu Ban)/Journal of Tianjin University Science and Technology, 2023, 56 (03): : 301 - 310
  • [44] Analyses of shaking table test of a tall building with steel structure connection
    Liu, Zhi
    Wang, Cuikun
    Stessa 2006, 2006, : 889 - 893
  • [45] Investigation of semi-rigid bolted beam connections on prefabricated frame joints
    Irtem, E
    Türker, K
    STRUCTURAL ENGINEERING AND MECHANICS, VOLS 1 AND 2, 1999, : 901 - 906
  • [46] Investigation of semi-rigid bolted beam connections on prefabricated frame joints
    Irtem, E
    Türker, K
    STRUCTURAL ENGINEERING AND MECHANICS, 2001, 12 (04) : 397 - 408
  • [47] A MODEL SHAKING TABLE TEST INVESTIGATION ON AN ASSEMBLY FRAME
    Duan, Shujin
    Wang, Zhenlu
    Yu, Yan
    Hua, Qian
    SUSTAINABLE SOLUTIONS IN STRUCTURAL ENGINEERING AND CONSTRUCTION, 2014, : 133 - 138
  • [48] Shaking table experiment of steel structure
    Shi, WX
    ADVANCES IN STEEL STRUCTURES, VOLS 1 AND 2, 1996, : 1015 - 1020
  • [49] Performance analysis and design of bolted connections in modularized prefabricated steel structures
    Liu, X. C.
    Pu, S. H.
    Zhang, A. L.
    Zhan, X. X.
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2017, 133 : 360 - 373
  • [50] Shaking table test on RC frame installed with metallic dampers using wall-pattern connections
    Shang, Qingxue
    Zhang, Xipeng
    Wang, Tao
    Zhou, Zhongyi
    Li, Jichao
    Tumu Gongcheng Xuebao/China Civil Engineering Journal, 2021, 54 (09): : 14 - 27