MWCNT-COOH/PDMS based dry ECG electrodes for ambulatory ECG recordings

被引:5
|
作者
Gandhi, Bani [1 ]
Raghava, N. S. [1 ]
机构
[1] Delhi Technol Univ DTU, Dept Elect & Commun Engn, Delhi 110042, India
关键词
Electrocardiogram; MWCNT-COOH; PDMS; IoT;
D O I
10.1016/j.matlet.2021.130972
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Highly conductive electrodes were fabricated using carboxylic functionalized Multiwalled Carbon Nanotubes (MWCNT-COOH), and Polydimethylsiloxane (PDMS) for continuous and long-term ECG monitoring. A two-step dispersion method was followed: first using magnetic stirring, and the second using ultrasonication. Thirteen electrodes with different concentrations of CNTs were fabricated using molds. The percolation threshold was observed at 4.5 wt%. These electrodes were subject to real-time and remote monitoring achieved by an Internetof-Things (IoT) system.
引用
收藏
页数:5
相关论文
共 50 条
  • [41] A low-power portable ECG sensor interface with dry electrodes
    浦小飞
    万磊
    张辉
    秦亚杰
    洪志良
    Journal of Semiconductors, 2013, 34 (05) : 104 - 109
  • [42] Characterization of Single Lead Continuous ECG Recording with Various Dry Electrodes
    ul Hassan, Muhammad Faiz
    Lai, Dakun
    Bu, Yuxiang
    ICCBB 2019: PROCEEDINGS OF THE 2019 3RD INTERNATIONAL CONFERENCE ON COMPUTATIONAL BIOLOGY AND BIOINFORMATICS, 2019, : 76 - 79
  • [43] A low-power portable ECG sensor interface with dry electrodes
    Pu Xiaofei
    Wan Lei
    Zhang Hui
    Qin Yajie
    Hong Zhiliang
    JOURNAL OF SEMICONDUCTORS, 2013, 34 (05)
  • [44] Reliable Motion Artifact Detection for ECG Monitoring Systems with Dry Electrodes
    Ottenbacher, Joerg
    Kirst, Malte
    Jatoba, Luciana
    Huflejt, Michal
    Grossmann, Ulrich
    Stork, Wilhelm
    2008 30TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-8, 2008, : 1695 - +
  • [45] Wearable Multi-lead ECG Recorder with Dry Metal Electrodes
    Hsu, Terng-Ren
    Hsu, Terng-Yin
    Yang, Shang-Yi
    Huang, Wei-Hsin
    Ou, Zong-Cheng
    Fan, Ching-Chih
    2016 11TH INTERNATIONAL MICROSYSTEMS, PACKAGING, ASSEMBLY AND CIRCUITS TECHNOLOGY CONFERENCE (IMPACT-IAAC 2016), 2016, : 73 - 76
  • [46] A low-power portable ECG sensor interface with dry electrodes
    浦小飞
    万磊
    张辉
    秦亚杰
    洪志良
    Journal of Semiconductors, 2013, (05) : 104 - 109
  • [47] Flexible polymeric dry electrodes for the long-term monitoring of ECG
    Baek, Ju-Yeoul
    An, Jin-Hee
    Choi, Jong-Min
    Park, Kwang-Suk
    Lee, Sang-Hoon
    SENSORS AND ACTUATORS A-PHYSICAL, 2008, 143 (02) : 423 - 429
  • [48] Skin-Potential Variation Insensitive Dry Electrodes for ECG Recording
    Pei, Weihua
    Zhang, He
    Wang, Yijun
    Guo, Xuhong
    Xing, Xiao
    Huang, Yong
    Xie, Yuxing
    Yang, Xiaowei
    Chen, Hongda
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2017, 64 (02) : 463 - 470
  • [49] Contact ECG Recording Using Copper and E-Textile Based Flexible Dry Electrodes
    Ren, Kai
    Ma, Ruyu
    Nikkhah, Mohammad R.
    Eggleston, Steve
    Ren, Yu-Jiun
    Behdad, Nader
    PROGRESS IN ELECTROMAGNETICS RESEARCH M, 2021, 101 : 47 - 58
  • [50] Contact ecg recording using copper and e-textile based flexible dry electrodes
    Ren K.
    Ma R.
    Nikkhah M.R.
    Eggleston S.
    Ren Y.-J.
    Behdad N.
    Progress In Electromagnetics Research M, 2021, 101 : 47 - 58