MWCNT-COOH/PDMS based dry ECG electrodes for ambulatory ECG recordings

被引:5
|
作者
Gandhi, Bani [1 ]
Raghava, N. S. [1 ]
机构
[1] Delhi Technol Univ DTU, Dept Elect & Commun Engn, Delhi 110042, India
关键词
Electrocardiogram; MWCNT-COOH; PDMS; IoT;
D O I
10.1016/j.matlet.2021.130972
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Highly conductive electrodes were fabricated using carboxylic functionalized Multiwalled Carbon Nanotubes (MWCNT-COOH), and Polydimethylsiloxane (PDMS) for continuous and long-term ECG monitoring. A two-step dispersion method was followed: first using magnetic stirring, and the second using ultrasonication. Thirteen electrodes with different concentrations of CNTs were fabricated using molds. The percolation threshold was observed at 4.5 wt%. These electrodes were subject to real-time and remote monitoring achieved by an Internetof-Things (IoT) system.
引用
收藏
页数:5
相关论文
共 50 条
  • [1] Development of Flexible Dry ECG Electrodes Based on MWCNT/PDMS Composite
    Chlaihawi, Amer Abdulmahdi
    Narakathu, Binu Baby
    Emamian, Sepehr
    Eshkeiti, Ali
    Reddy, Sai Guruva Avuthu
    Bazuin, Bradley J.
    Atashbar, Massood Z.
    2015 IEEE SENSORS, 2015, : 221 - 224
  • [2] A Low-Power On-Chip ECG Monitoring System Based on MWCNT/PDMS Dry Electrodes
    Tasneem, Nishat T.
    Pullano, Salvatore A.
    Critello, Costantino Davide
    Fiorillo, Antonino S.
    Mahbub, Ifana
    IEEE SENSORS JOURNAL, 2020, 20 (21) : 12799 - 12806
  • [3] Screen Printed MWCNT/PDMS Based Dry Electrode Sensor for Electrocardiogram (ECG) Measurements
    Chlaihawi, Amer A.
    Narakathu, Binu B.
    Eshkeiti, Ali
    Emamian, Sepher
    Avuthu, Sai G. R.
    Atashbar, Massood Z.
    2015 IEEE INTERNATIONAL CONFERENCE ON ELECTRO/INFORMATION TECHNOLOGY (EIT), 2015, : 526 - 529
  • [4] AMBULATORY ECG RECORDINGS - A SPECTRUM OF TECHNOLOGY
    GRABOYS, TB
    ARMINGTON, R
    KIELY, JP
    MEDICAL INSTRUMENTATION, 1981, 15 (04): : 237 - 241
  • [5] ROLE OF ECG IN AMBULATORY EEG RECORDINGS
    NOUSIAINEN, U
    UUSITUPA, M
    MERVAALA, E
    YLINEN, A
    SIVENIUS, J
    RIEKKINEN, P
    ACTA NEUROLOGICA SCANDINAVICA, 1988, 77 : 96 - 96
  • [6] Study of PDMS Material for ECG Electrodes
    Yadhuraj, S. R.
    Sudarshan, B. G.
    Kumar, Prasanna S. C.
    Kumar, Mahesh D.
    MATERIALS TODAY-PROCEEDINGS, 2018, 5 (04) : 10635 - 10643
  • [7] CNT/PDMS Composite Flexible Dry Electrodes for Long-Term ECG Monitoring
    Jung, Ha-Chul
    Moon, Jin-Hee
    Baek, Dong-Hyun
    Lee, Jae-Hee
    Choi, Yoon-Young
    Hong, Joung-Sook
    Lee, Sang-Hoon
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2012, 59 (05) : 1472 - 1479
  • [8] Device agnostic AI-based analysis of ambulatory ECG recordings
    Kennedy, Alan
    Doggart, Peter
    Smith, Stephen W.
    Finlay, Dewar
    Guldenring, Daniel
    Bond, Raymond
    McCausland, Christopher
    McLaughlin, James
    JOURNAL OF ELECTROCARDIOLOGY, 2022, 74 : 154 - 157
  • [9] Novel dry electrodes for ECG monitoring
    Gruetzmann, Anna
    Hansen, Stefan
    Mueller, Joerg
    PHYSIOLOGICAL MEASUREMENT, 2007, 28 (11) : 1375 - 1390
  • [10] METHODS OF IMPROVING THE ACCURACY OF AMBULATORY BP AND ECG RECORDINGS
    STOTT, FD
    CASHMAN, PMM
    CLINICAL AND EXPERIMENTAL HYPERTENSION PART A-THEORY AND PRACTICE, 1985, 7 (2-3) : 327 - 333